Kai Peiponen

Kai Peiponen


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Benjamin O. AsamoahBenjamin O. Asamoah
Benjamin O. Asamoah
EUEmilia Uurasjärvi
Emilia Uurasjärvi
JRJukka Räty
Jukka Räty
AKArto Koistinen
Arto Koistinen
MRMatthieu Roussey
Matthieu Roussey
KPKai Peiponen
Kai Peiponen
The prevalent nature of micro and nanoplastics (MP/NPs) on environmental pollution and health-related issues has led to the development of various methods, usually based on Fourier-transform infrared (FTIR) and Raman spectroscopies, for their detection. Unfortunately, most of the developed techniques are laboratory-based with little focus on in situ detection of MPs. In this review, we aim to give an up-to-date report on the different optical measurement methods that have been exploited in the screening of MPs isolated from their natural environments, such as water. The progress and the potential of portable optical sensors for field studies of MPs are described, including remote sensing methods. We also propose other optical methods to be considered for the development of potential in situ integrated optical devices for continuous detection of MPs and NPs. Integrated optical solutions are especially necessary for the development of robust portable and in situ optical sensors for the quantitative detection and classification of water-based MPs.

1 September 2019 in Chemosphere
Verified
Journal Article
Open access
Benjamin O. AsamoahBenjamin O. Asamoah
Benjamin O. Asamoah
Boniphace KanyathareBoniphace Kanyathare
Boniphace Kanyathare
MRMatthieu Roussey
Matthieu Roussey
KPKai Peiponen
Kai Peiponen
Microplastic pollution in water bodies is an alarming problem which needs to be addressed. However, issues such as size, shape and their appearance to light (transparent or translucent) make it difficult to be optically detected. Here, a feasibility study of a portable prototype optical sensor with the capability of measuring simultaneously specular laser light reflection and transmission from microplastic particles is presented. The specular reflection signal and the transmitted interference pattern were recorded with a photodiode and a CCD camera, respectively. With the combination of these two modes of detection, it is possible to screen the type, size, and nonplanarity of two microplastics types, i.e., transparent polyethylene terephthalate (PET) and translucent low-density polyethylene (LDPE), in a volume of freshwater, with high confidence. In principle, the prototype could be used for the detection of both floating microplastics as well as microplastics experiencing sedimentation in natural water bodies, and in water filtration in water treatment plants.

1 June 2020 in Chemosphere
Verified
Journal Article
Open access
Boniphace KanyathareBoniphace Kanyathare
Boniphace Kanyathare
Benjamin O. AsamoahBenjamin O. Asamoah
Benjamin O. Asamoah
muhammad umair ishaqmuhammad umair ishaq
muhammad umair ishaq
JAJames Amoani
James Amoani
JRJukka Räty
Jukka Räty
KPKai Peiponen
Kai Peiponen
Erosion of microplastics due to residence time in aquatic environments causes roughening of the microplastic. Unfortunately, currently used measurement methods do not provide information on the surface roughness of the microplastic embedded in water. In this study we propose a novel method by using transmittance to get information on the magnitude of the surface roughness of microplastics and to rank microplastics by thickness. For such a purpose, we studied optical properties such as dispersion, absorption of both plastics and water in the partial spectral range of visible light (Vis), transmission and scattering of light by plastic sheets, as well as, the calculated sample thickness in the Vis region. These were explored for the detection of both smooth and roughened plastic sheets immersed in water. Moreover, by using the transmission spectrum and refractive index of both plastic and water it is possible to estimate the average surface roughness of plastic samples. Our results suggest that the optical properties in the Vis region offer an interesting way for the detection of both rough and smooth plastic sheets and for ranking the type of plastics in an aquatic environment.

14 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
BKBoniphace Kanyathare
Boniphace Kanyathare
KPKai Peiponen
Kai Peiponen
Adulteration of fuels is a major problem, especially in developing and third world countries. One such case is the adulteration of diesel oil by kerosene. This problem contributes to air pollution, which leads to other far-reaching adverse effects, such as climate change. The objective of this study was to develop a relatively easy measurement method based on an inexpensive, handheld Abbe refractometer for the detection of adulteration and estimation of the ascending order of the amount of kerosene present in adulterated samples in field conditions. We achieved this by increasing the volume of pure diesel sample in the adulterated diesel oil, and measuring the trend of refractive index change, and next, exploiting the true and ideal permittivities of the binary mixture. The permittivity can be obtained with the aid of the measured refractive index of a liquid. Due to the molecular interactions, the true and ideal permittivities of diesel–kerosene binary liquid mixture have a mismatch which can be used to screen for adulterated diesel oils. The difference between the true and the ideal permittivity is the so-called excess permittivity. We first investigated a training set of diesel oils in laboratory in Finland, using the accurate table model Abbe refractometer and depicting the behavior of the excess permittivity of the mixture of diesel oil and kerosene. Then, we measured same samples in the laboratory using a handheld refractometer. Finally, preliminary field measurements using the handheld device were performed in Tanzania to assess the accuracy and possibility of applying the suggested method in field conditions. We herein show that it is not only possible to detect even relatively low adulteration levels of diesel in kerosene—namely, 5%, 10%, and 15%—but also it is possible to monitor the ascending order of adulteration for different adulterated diesel samples. We propose that the method of increasing the volume of an unknown (suspected) diesel oil sample by adding a known authentic diesel sample and monitoring excess permittivity is useful for the screening of adulterated diesel oil in field measurement conditions.

1 April 2013 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
KPKai Peiponen
Kai Peiponen
PSP. Silfsten
P. Silfsten
JPJ. Pajander
J. Pajander
JKJ. Ketolainen
J. Ketolainen

5 December 2009 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
MJMikko Juuti
Mikko Juuti
KKKimmo Koivunen
Kimmo Koivunen
MSMartti Silvennoinen
Martti Silvennoinen
HPHannu Paulapuro
Hannu Paulapuro
KPKai Peiponen
Kai Peiponen