Nunzio Burgio

Dr. Nunzio Burgio

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1992 in Materials Science Forum
Verified
Journal Article
Closed access
PDF file
WGW. Guo
W. Guo
SMS. Martelli
S. Martelli
FPF. Padella
F. Padella
MMMauro Magini
Mauro Magini
NBNunzio Burgio
Nunzio Burgio
UFU. Franzoni
U. Franzoni

1 July 2007 in Anti-Cancer Agents in Medicinal Chemistry
Verified
Journal Article
Closed access
SBS. Buono
S. Buono
NBNunzio Burgio
Nunzio Burgio
MHM. Hamoudeh
M. Hamoudeh
HFH. Fessi
H. Fessi
EHE. Hiltbrand
E. Hiltbrand
SMS. Mehier-Humbert
S. Mehier-Humbert
Cancer often remains an incurable disease, despite significant progresses in diagnosis and treatment that have been made. Specifically, the use of nuclear medicine in oncology is greatly contributing to both imaging and therapy aspects. Targeted therapies are a major field of interest since it increases efficiency and reduces side effects. Brachytherapy is among the most valuable of recent developments for treating localized tumours resulting in improvements in improved quality of life. This is primarily because it irradiates cancerous cells most exclusively while barely effecting healthy tissue. The use of radiochemicals implies specific management for production, transport and handling that have limited the development of this technique. This review article describes brachytherapy and their latest developments. Furthermore, alternative activation methods for the production of radioisotopes and a novel delivery system for targeted multi-therapy by using PLA-ferrite nanospheres are described.

9 November 2017 in The European Physical Journal C
Verified
Journal Article
Open access
PDF file
TCThe MOSCAB Collaboration:
The MOSCAB Collaboration:
AAA. Antonicci
A. Antonicci
Miguel ArdidMiguel Ardid
Miguel Ardid
RBR. Bertoni
R. Bertoni
GBG. Bruno
G. Bruno
LZL. Zanotti
L. Zanotti
The MOSCAB experiment (Materia OSCura A Bolle) uses the “geyser technique”, a variant of the superheated liquid technique of extreme simplicity. Operating principles of the new dark matter detector an

4 May 2022 in Radiation Detection Technology and Methods
Verified
Journal Article
Open access
PDF file
NBNunzio Burgio
Nunzio Burgio
LCL. Cretara
L. Cretara
Massimo CorcioneMassimo Corcione
Massimo Corcione
MFM. Frullini
M. Frullini
LIL. Iannascoli
L. Iannascoli
DPD. Paglialunga
D. Paglialunga
Purpose: The AstroBio Cube Satellite (ABCS) will deploy within the inner Van Allen belt on the Vega C Maiden Flight launch opportunity of the European Space Agency. At this altitude, ABCS will experience radiation doses orders of magnitude greater than in low earth orbit, where CubeSats usually operate. The paper aims to estimate the irradiation effect on the ABCS payload in the orbital condition, their possible mitigation designing shielding solutions and performs a preliminary representativity simulation study on the ABCS irradiation with fission neutron at the TAPIRO (TAratura Pila Rapida Potenza 0) nuclear research reactor facility at ENEA. Methods: We quantify the contributions of geomagnetically trapped particles (electron and proton), Galactic Cosmic Rays (GCR ions), Solar energetic particle within the ABCS orbit using the ESA’s SPace ENVironment information system. FLUKA (Fluktuierende Kaskade—Fluctuating Cascade) code models the ABCS interaction with the orbital source. Results: We found a shielding solution of the weight of 300 g constituted by subsequent layers of tungsten, resins, and aluminium that decreases on average the 20% overall dose rate relative to the shielding offered by the only satellite’s structure. Finally, simulations of neutron irradiation of the whole ABCS structure within the TAPIRO’s thermal column cavity show that a relatively short irradiation time is requested to reach the same level of 1 MeV neutron Silicon equivalent damage of the orbital source. Conclusions: The finding deserves the planning of a future experimental approach to confirm the TAPIRO’s performance and establish an irradiation protocol for testing aerospatial electronic components.

22 November 2019 in The European Physical Journal C
Verified
Journal Article
Open access
PDF file
Miguel ArdidMiguel Ardid
Miguel Ardid
ABAndrea Baschirotto
Andrea Baschirotto
NBNunzio Burgio
Nunzio Burgio
Massimo CorcioneMassimo Corcione
Massimo Corcione
LCL. Cretara
L. Cretara
LZL. Zanotti
L. Zanotti
In the framework of the search for dark matter in the form of WIMPs using superheated liquids, a study is conducted to establish a computational procedure aimed at determining how the thermodynamic conditions kept inside a particle detector affect the acoustic signal produced by bubble nucleation. It is found that the acoustic energy injected into the liquid by the growing vapour bubble increases as the liquid pressure is decreased and the superheat degree is increased, the former effect being crucial for the generation of a well-intelligible signal. A good agreement is met between the results of the present study and some experimental data available in the literature for the amplitude of the acoustic signal. Additionally, the higher loudness of the alpha-decay events compared with those arising from neutron-induced nuclear recoils is described in terms of multiple nucleations.

3 May 2023 in The European Physical Journal C
Verified
Journal Article
Open access
PDF file
RBR. Bertoni
R. Bertoni
GBG. Bruno
G. Bruno
NBNunzio Burgio
Nunzio Burgio
Massimo CorcioneMassimo Corcione
Massimo Corcione
LCL. Cretara
L. Cretara
LZL. Zanotti
L. Zanotti
A measurement of the fast neutron background in the Gran Sasso underground laboratory has been performed by the MOSCAB thermodynamic bubble chamber, a neutron detector which identifies fast neutrons passing through the metastable fluid by scattering ions. The result of this measurement confirms the results previously obtained using detectors based on totally different techniques, thus corroborating the previous results in terms of both integral intensity and spectral characteristics, at least in the energy region where the current measurement technique is sensitive.