This work presents the theoretical investigations results for the brick wall thermal protection properties exterior corner with the insulated layer SUPERROCK mineral wool. As the outer corner of the enclosing structures has lower thermal protection properties than the other part of the wall, it needs additional insulation. Two variants of additional insulation were considered in the work, in the deepened outer surface and in the middle of the brick wall. In this case, the additional heater was not continuous, but divided into two parts and shifted from the corner. The length and volume of additional insulation for different variants were determined. The optimal variant of the proposed schemes was determined by the minimum volume of the heater and compared with the existing ones. The volume of additional insulation is set at 1 meter of the fence height. For the proposed variant of the location for the heater in the brick wall middle, its thickness in the brick cavity, the length and offset from the corner magnitude were determined. For a location-variant of the heater in the deepened on the outer surface of the fence bricklayer, the length of the additional insulation and its displacement from the corner were determined. The thickness of additional insulation was taken 130 mm (width of the brick and seam between the bricks). Studies were carried out for the first temperature zone.
A survey and assessment of the technical condition of basement and semi-basement structures in public buildings aged 60 to 130 years were conducted to evaluate their suitability for use as basic shelters. Based on the survey results, the most adverse impacts were identified, including changes in groundwater levels, improper building operation, and the characteristic damages to underground structural elements. Structural solutions were proposed to eliminate the consequences of these damages. The reviewed cases indicate that the vertical and horizontal waterproofing systems used during construction cannot perform their function throughout the building’s entire life cycle. When designing new buildings, waterproof materials should be used for the enclosing structures of underground premises. While this may have a higher initial cost than membrane or coating waterproofing, considering life-cycle costs, it can provide a positive economic effect and improve the quality and comfort of the indoor environment.
The thermal protection level of the first mass series panel buildings (series 111-94) is the lowest among residential buildings in Poltava. The problems of these buildings’ thermal modernization, is consideration of heat-conducting inclusions effect on the reduced resistance to heat transfer. In the studies such heat-conducting inclusions as the panel joints’ design, the window slope and the external wall geometry (the external corner) were taken into account. Studies were performed for the four pattern sections of the outer wall. Panels of two thickness variants with two joint designs were under consideration.To analyze the thermal protection level, the results of the two-dimensional temperature fields’ calculations were used. The analysis of the wall panels’ thermal protection level before the thermal modernization was performed. The magnitude of the heat conducting inclusions effect on reduced resistance of the walling to the heat transfer before and after the thermal modernization is determined. Possible ways of improving the wall panels’ heat-protective properties to the level of the standards in Ukraine are considered. The optimal variant of insulation for each pattern was chosen.