The operational energy efficiency of new buildings in the EU should be at the level of ultra-low or near-zero energy buildings. It is therefore relatively difficult to achieve further energy savings. However, the pre-operational phase—raw material sourcing, manufacturing, transportation, and construction—offers significant energy savings and greenhouse gas reduction opportunities, referred to as embodied energy and equivalent CO2 emissions. Unlike operational energy, no standard or legislative criteria have yet been established for embodied energy. Setting maximum embodied energy values converted to the unit of heated building area, accounting for building shape factor, and differentiating between high-mass and lightweight constructions are proposed. This study illustrates assessing environmental indicators based on building shape, highlighting the necessity of relative assessments over absolute values to favour energy efficiency. It also emphasizes that precise criteria should derive from authentic data collected during the energy certification and building permitting processes. Integrating assessments of embodied energy and operational energy demand facilitates a comprehensive evaluation of buildings’ environmental performance.
1 December 2019 in IOP Conference Series: Materials Science and Engineering
The article presents the results of stability calculation of reinforced concrete columns using light steel thin-walled structures investigation. Two steel thin-walled profiles of type “C” or “∑” were used as the steel shell of such columns. The profiles were combined in the form of a box section with bolts. To increase the stability of the shell, the inner cavity was filled with concrete with lightweight aggregates. Technique of steel thin-walled elements stability calculation with consideration of concreting and joint work of the whole structure involves two types of calculation: for central compression and for joint action of compression and uniaxial bending. To verify the analytical calculations, a computer simulation was performed, which proved the correctness of the theoretical calculations and made it possible to clearly observe the different forms of column stability loss at different coefficients of overload. It was found that the increase of bearing capacity due to the thickness of the profile varies within 2-10%. For smaller profiles this difference is significant (10-23%), and for larger profiles - smaller (5-8%). This is due to the complexity of the manufacturing technology and the cost of materials.
A survey and assessment of the technical condition of basement and semi-basement structures in public buildings aged 60 to 130 years were conducted to evaluate their suitability for use as basic shelters. Based on the survey results, the most adverse impacts were identified, including changes in groundwater levels, improper building operation, and the characteristic damages to underground structural elements. Structural solutions were proposed to eliminate the consequences of these damages. The reviewed cases indicate that the vertical and horizontal waterproofing systems used during construction cannot perform their function throughout the building’s entire life cycle. When designing new buildings, waterproof materials should be used for the enclosing structures of underground premises. While this may have a higher initial cost than membrane or coating waterproofing, considering life-cycle costs, it can provide a positive economic effect and improve the quality and comfort of the indoor environment.
20 June 2018 in International Journal of Engineering & Technology
Characteristic damages Groups of public buildings combined roofs are distinguished. The recommendations on the thermal modernization of combined roof structures are given. The heat-shielding properties of the combined roofs structures, their moisture state are studied. Recommendations for additional insulation of these structures are given, which allow bringing the heat-protective properties of the considered constructions to construction regulations.