Compensation for the hemispherical resonator gyroscope detection error significantly improves gyroscope performance as well as provides a basis for the implementation of high precision control algorithms. In this paper, an identification method is proposed in which the precession factor and the detection error parameters including gain error, non-orthogonal angle error, and phase error can be identified simultaneously in a single test. Firstly, we analyze the detection error caused by gyroscope manufacturing as well as the inconsistency in circuit device parameters. Secondly, the detection error is modeled, and the impact of the error on the standing wave azimuth detection and the control system is discussed. Thirdly, a method is presented for identifying the error parameters based on the nonlinear least squares. Finally, experiments are conducted to verify the effectiveness of the identification and compensation method. As a result of compensation, the bias instability decreases by 33 times from 5.08°/h to 0.15°/h, and the scale factor nonlinearity decreases by 4 times from 50.26ppm to 10.23ppm.
5 December 2024 in IEEE Transactions on Instrumentation and Measurement
Coriolis Vibratory Gyros commonly employ virtual precession for the online calibration of assembly, damping, and angular errors. However, the impact of precession stability on gyro performance is often overlooked in the calibration process. This paper presents a novel method for virtual precession self-calibration from the signal processing perspective. Initially, a comprehensive error model for virtual precession is established, elucidating the influencing mechanism of resonant frequency and high voltage changes on the precession rate. Subsequently, a sinusoidal signal is introduced into the virtual precession rate to separate the precession error from the resonator structure error. Finally, the dynamic recursive least squares algorithm (DRLS) is employed for real-time characterization of the precession error, and the identification results are fed back to the control system for self-calibration of the virtual precession. The experimental results reveal that following self-calibration, the gyro’s stabilization time in a variable temperature environment is reduced significantly from 50 minutes to 10 minutes. Additionally, the rate error diminishes from 4.3×10-3°/s to 1.6×10-4°/s, and the rate stability at different temperatures decreases from 6.35°/h to 0.24°/h. This method is not constrained by the gyro’s structure and environment, making it applicable to large-scale engineering applications.
The vector control method is applied to a whole angle hemispherical resonator gyroscope (HRG). The detection and control of the resonator vibration state are implemented using orthogonal X/Y channels. However, the performance of the HRG is limited by the asymmetry in the gain and phase delay of X/Y channels. To address these issues, a novel detection circuit is proposed. The circuit leverages the closed-loop characteristics to achieve symmetry and stability in the X/Y channel gain while simultaneously eliminating phase delays within the loop. Firstly, a closed-loop single-channel time division multiplexing circuit is designed to overcome the deficiencies of the traditional dual-channel circuit. Secondly, a model is developed to analyze the time division detection errors, and an improved demodulation method is proposed to mitigate detection errors. Lastly, experimental results demonstrate that the designed circuit successfully suppresses drift in both gain and phase delay within the loop, confirming the effectiveness of the proposed solution in enhancing the performance of the HRG.
21 July 2025 in IEEE Transactions on Instrumentation and Measurement
By adjusting the signal demodulation architecture and optimizing the control circuit configuration, the phase errors of the Coriolis gyroscope can be substantially mitigated. However, these approaches fail to account for the influence of phase asymmetry error on gyro performance. This paper proposes a self-calibration method for phase errors based on virtual precession. First, a dynamic analysis model is established to examine the impact of x/y-channel phase errors and their asymmetry on the gyro control system. Second, phase errors are decoupled from resonator structural errors via forward-reverse rotation modulation. Building on this, a real-time characterization method for phase errors that utilizes the evolution law of quadrature control voltage is developed. Finally, based on the identification results, a self-calibration method for phase errors is designed to offset the phase delay of the control system from the signal processing perspective. Experimental results demonstrate that after self-calibration, the second and fourth harmonics of the gyro output at different rotational speeds are reduced by 98.85% and 89.58%, respectively. Additionally, the scale factor nonlinearity and circumferential drift instability are reduced by 95.40% and 97.52%, respectively. This method is not constrained by the gyro structure and the x/y-channel control strategy, making it broadly applicable to other axisymmetric Coriolis vibratory gyros.
30 August 2018 in Journal of Physics: Conference Series
The performance of the hemispherical resonator gyroscope (HRG) in whole-angle (WA) mode is affected by the angle-dependent harmonic drift. Suppressing this drift is essential to improve its temperature stability and operational range. In this article, a novel real-time method for eliminating harmonic drift based on a forward and reverse precession (FRP) control scheme is proposed. First, the sources of harmonic drift in HRG are analyzed. The HRG dynamical equations incorporating multiple error sources are derived and analyzed through numerical simulation. Subsequently, a real-time error identification algorithm is developed and validated through simulation. Finally, a temperature experiment is conducted to validate the method. The experimental results demonstrate that the proposed method can accurately identify and compensate for errors at different temperatures, effectively suppressing the harmonic components in angular velocity by more than 97%. The bias instability (BI) of the HRG remains consistently around 0.024°/h across various temperatures, indicating strong temperature stability. Additionally, the scale factor nonlinearity (SFN) is reduced five-fold to 0.84 ppm. Most importantly, this method can be applied to all Coriolis vibratory gyroscopes to effectively eliminate their common angle-dependent harmonic drift.