Eduardo Venegas-Reyes

Dr. Eduardo Venegas-Reyes

Seguridad Hídrica, Instituto Mexicano de Tecnología del Agua, Jiutepec, Morelos, Mexico

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
Oscar May TzucOscar May Tzuc
Oscar May Tzuc
Bassam AliBassam Ali
Bassam Ali
MSM. A. Escalante Soberanis
M. A. Escalante Soberanis
Eduardo VenegasEduardo Venegas
Eduardo Venegas
Oscar Alfredo Jaramillo-SalgadoOscar Alfredo Jaramillo-Salgado
Oscar Alfredo Jaramillo-Salgado
YHY. El Hamzaoui
Y. El Hamzaoui
In this paper, an artificial neural network inverse (ANNi) model is applied to optimize the thermal performance (η) of parabolic trough concentrators. A feedforward neural network architecture is trained using an experimental database from parabolic trough concentrators operations. Rim angle (φ r), inlet (Tin) and outlet (Tout) fluid temperatures, ambient temperature (Ta), water flow (Fw), direct solar radiation (Gb), and the wind velocity (Vw) were used as main input variables within the neural network model to estimate the thermal performance with a correlation coefficient of R2 = 0.9996 between experimental and simulated values. The sensitivity analysis is carried out to verify the effect of all input variables. The optimal operation conditions of parabolic trough concentrators are established using artificial neural network inverse modeling (ANNi) to achieve optimal operation conditions of parabolic trough concentrators. The results indicated that ANNi is a feasible tool for Parabolic Trough Concentrators optimization.

16 May 2018 in Energies
Verified
Journal Article
Open access
PDF file
Yuridiana Rocio Galindo LunaYuridiana Rocio Galindo Luna
Yuridiana Rocio Galindo Luna
EAEfraín Gómez Arias
Efraín Gómez Arias
Rosenberg J RomeroRosenberg J Romero
Rosenberg J Romero
Eduardo VenegasEduardo Venegas
Eduardo Venegas
Moisés Montiel-GonzálezMoisés Montiel-González
Moisés Montiel-González
JSJorge Diaz Salgado
Jorge Diaz Salgado
Solar and geothermal energies are considered cleaner and more useful energy sources that can be used to avoid the negative environmental impacts caused by burning fossil fuels. Several works have reported air-conditioning systems that use solar energy coupled to geothermal renewable energy as a thermal source. In this study, an Absorption Air-Conditioning System (AACS) used sodium hydroxide-water (NaOH-H2O) instead of lithium bromide-water to reduce the cost. Low enthalpy geothermal heat was derived from two shallow wells, 50 and 55 m deep. These wells are of interest due to the thermal recovery (temperature vs. time) of 56.2 °C that was possible at the maximum depth, which can be used for the first stage of the process. These wells were coupled with solar energy as a geothermal energy application for direct uses such as air-conditioning systems. We studied the performance of an absorption cooling system operating with a NaOH-H2O mixture and using a parabolic trough plant coupled with a low enthalpy geothermal heat system as a hybrid heat source, as an alternative process that can help reduce operating costs and carbon dioxide emissions. The numerical heat transfer results showed the maximum convective heat transfer coefficient, as function of fluid velocity, and maximum temperature for a depth higher than 40 m. The results showed that the highest temperatures occur at low fluid velocities of less than or equal to 5.0 m/s. Under these conditions, reaching temperatures between 51.0 and 56.2 °C in the well was possible, which is required of the geothermal energy for the solar energy process. A water stream was used as the working fluid in the parabolic trough collector field. During the evaluation stage, the average experimental storage tank temperature achieved by the parabolic trough plant was 93.8 °C on October 23 and 92.9 °C on October 25, 2017. The numerical simulation used to evaluate the performance of the absorption cycle used a generator temperature of 90 °C, a condenser and absorber temperature at 35 °C, and an evaporator temperature of 10 °C. The Coefficient of Performance was calculated as 0.71 under design conditions.

7 February 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jonathan Ibarra BahenaJonathan Ibarra Bahena
Jonathan Ibarra Bahena
Eduardo VenegasEduardo Venegas
Eduardo Venegas
Yuridiana Rocio Galindo LunaYuridiana Rocio Galindo Luna
Yuridiana Rocio Galindo Luna
WRWilfrido Rivera
Wilfrido Rivera
Rosenberg J RomeroRosenberg J Romero
Rosenberg J Romero
UDUlises Dehesa-Carrasco
Ulises Dehesa-Carrasco
In absorption cooling systems, the desorber is a component that separates the refrigerant fluid from the liquid working mixture, most commonly completed by boiling separation; however, the operation temperature of boiling desorbers is generally higher than the low-enthalpy energy, such as solar, geothermal, or waste heat. In this study, we used a hydrophobic membrane desorber to separate water vapor from an aqueous LiBr solution. Influencing factors, such as the H2O/LiBr solution and cooling water temperatures, were tested and analyzed. With the experimental data, a solar collector system was simulated on a larger scale, considering a 1 m2 membrane. The membrane desorber evaluation shows that the desorption rate of water vapor increased as the LiBr solution temperature increased and the cooling water temperature decreased. Based on the experimental data from the membrane desorber/condenser, a theoretical heat load was calculated to size a solar system. Meteorological data from Emiliano Zapata in Mexico were considered. According to the numerical result, nine solar collectors with a total area of 37.4 m2 provide a solar fraction of 0.797. The membrane desorber/condenser coupled to the solar system can provide an average of 16.8 kg/day of refrigerant fluid that can be used to produce a cooling effect in an absorption refrigerant system.

26 June 2021 in Membranes
Verified
Journal Article
Open access
PDF file
Jonathan Ibarra BahenaJonathan Ibarra Bahena
Jonathan Ibarra Bahena
WRWilfrido Rivera
Wilfrido Rivera
SNSandra Daniela Nanco-Mejía
Sandra Daniela Nanco-Mejía
Rosenberg J RomeroRosenberg J Romero
Rosenberg J Romero
Eduardo VenegasEduardo Venegas
Eduardo Venegas
UDUlises Dehesa-Carrasco
Ulises Dehesa-Carrasco
In absorption systems using the aqueous lithium bromide mixture, the Coefficient of Performance is affected by the desorber. The main function of this component is to separate the refrigerant fluid from the working mixture. In conventional boiling desorbers, constant heat flux and vacuum pressure conditions are necessary to carry out the desorption process, and usually, the absorbers are heavy and bulky; thus, they are not suitable in compact systems. In this study, a membrane desorber was evaluated, operating at atmospheric pressure conditions with a water/lithium bromide solution with a concentration of 49.6% w/w. The effects of the solution temperature, solution mass flow, and condensation temperature on the desorption rate were analyzed. The maximum desorption rate value was 6.1 kg/m2h with the following operation conditions: the solution temperature at 95.2 °C, the solution mass flow at 4.00 × 10−2 kg/s, and the cooling water temperature at 30.1 °C. On the other hand, the minimum value was 1.1 kg/m2h with the solution temperature at 80.2 °C, the solution mass flow at 2.50 × 10−2 kg/s, and the cooling water temperature at 45.1 °C. The thermal energy efficiency, defined as the ratio between the thermal energy used to evaporate the refrigerant fluid with respect to the total thermal energy entering the membrane desorber, varied from 0.08 to 0.30. According to the results, a high solution mass flow, a high solution temperature, and a low condensation temperature lead to an increase in the desorption rate; however, a low solution mass flow enhanced the thermal energy efficiency. The proposed membrane desorber could replace a conventional boiling desorber, especially in absorption cooling systems that operate at high condensation temperatures as in warm weather regions.

17 May 2019 in Processes
Verified
Journal Article
Open access
PDF file
Eduardo VenegasEduardo Venegas
Eduardo Venegas
NONaghelli Ortega-Avila
Naghelli Ortega-Avila
NRNorma A. Rodriguez-Muñoz
Norma A. Rodriguez-Muñoz
MNMario Nájera-Trejo
Mario Nájera-Trejo
IMIgnacio Martin-Dominguez
Ignacio Martin-Dominguez
Jonathan Ibarra BahenaJonathan Ibarra Bahena
Jonathan Ibarra Bahena
The analysis of solar thermal systems through numerical simulation is of great importance, since it allows predicting the performance of many configurations in any location and under different climatic conditions. Most of the simulation tools are commercial and require different degrees of training; therefore, it is important to develop simple and reliable methodologies to obtain similar results. This study presents a parametric methodology to size stationary solar collector fields, with operating temperatures up to 150 °C. The costs of the collector loop piping and the pumping power of different series–parallel arrays is considered. The proposed tool was validated with experimental data and through simulations using commercial software. The tool allows establishing series–parallel arrays and calculates the volume of the storage tank according to the thermal load. The calculation is based on the system energy balance, where the mass flow and the heat losses in the interconnections of the collectors are taken into account. The number of collectors and the optimal series–parallel array were determined. The results show deviations lower than 7% in the relative error of the temperature profiles and in the solar fraction, with respect to the results obtained by dynamic simulations.

29 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ICIrving Alejandro Chávez-Bermúdez
Irving Alejandro Chávez-Bermúdez
NRNorma A. Rodriguez-Muñoz
Norma A. Rodriguez-Muñoz
Eduardo VenegasEduardo Venegas
Eduardo Venegas
Loreto ValenzuelaLoreto Valenzuela
Loreto Valenzuela
NONaghelli Ortega-Avila
Naghelli Ortega-Avila
Solar air heaters can reduce climate change by replacing conventional fossil fuel-burning technologies in drying and space heating applications. Concentrating solar technologies, such as compound parabolic concentrators, allow air temperatures up to 120 °C; however, it is desirable to improve their heat transfer to reduce the space requirements for their installation. In this work, a parabolic concentrator composed of a flat receiver designed to recover heat from the cover–receiver–reflectors cavity is analyzed, operating it as a U-shape double pass solar heater. With this operation, first, the air flows through the cavity, and then it is incorporated into the duct, where the dominant heat gain occurs due to the capture of solar radiation. Thus, four input–output configurations in the cavity were modeled through dynamic simulations to determine the influence of the inlet and outlet air flow positions on the solar concentrator outlet temperature. Therefore, the incorporation of the first pass has a contribution of between 36% and 45% in useful energy gain, showing that this appropriate and relatively simple strategy can be implemented to improve the thermal performance of solar air collectors, resulting in instantaneous efficiencies higher than 75%. However, the simulation results demonstrate that the position of the inlets and outlets does not significantly impact the efficiency and outlet temperature.