ID15A is a newly refurbished beamline at the ESRF devoted to operando and time-resolved diffraction and imaging, total scattering and diffraction computed tomography. The beamline is optimized for rapid alternation between the different techniques during a single operando experiment in order to collect complementary data on working systems. The high available energy (up to 120 keV) means that even bulky and highly absorbing systems may be studied. The beamline is equipped with optimized focusing optics and a photon-counting CdTe pixel detector, allowing for both unprecedented data quality at high energy and for very rapid triggered experiments. A large choice of imaging detectors and ancillary probes and sample environments is also available.
22 February 2022 in Journal of Synchrotron Radiation
ID23-2 is a fixed-energy (14.2 keV) microfocus beamline at the European Synchrotron Radiation Facility (ESRF) dedicated to macromolecular crystallography. The optics and sample environment have recently been redesigned and rebuilt to take full advantage of the upgrade of the ESRF to the fourth generation Extremely Brilliant Source (ESRF-EBS). The upgraded beamline now makes use of two sets of compound refractive lenses and multilayer mirrors to obtain a highly intense (>1013 photons s−1) focused microbeam (minimum size 1.5 µm × 3 µm full width at half-maximum). The sample environment now includes a FLEX-HCD sample changer/storage system, as well as a state-of-the-art MD3Up high-precision multi-axis diffractometer. Automatic data reduction and analysis are also provided for more advanced protocols such as synchrotron serial crystallographic experiments.
6 September 2010 in X-Ray Optics and Instrumentation
This paper provides a comprehensive overview on the utilization of curved graded multilayer coatings as focusing elements for hard X-rays. It concentrates on the Kirkpatrick-Baez (KB) focusing setup that has been developed at 3rd generation synchrotron sources worldwide. The optical performance of these devices is evaluated applying analytical and numerical approaches. The essential role of the multilayer coating and its meridional d-spacing gradient are discussed as well as important technological issues. Experimental data and examples of operational KB focusing devices and applications complement the work.
10 October 2019 in Journal of Synchrotron Radiation
The surface figure error of a hard X-ray mirror was improved by combining differential deposition and off-line metrology tools. Thin Cr layers were deposited on flat substrates by DC magnetron sputtering. The substrates were moved in front of a beam-defining aperture. The required velocity profile was calculated using a deconvolution algorithm. The Cr thickness profiles were measured directly using hard X-ray reflectivity data. The surface figure was characterized using conventional visible-light metrology instrumentation (long trace profiler) before and after the deposition. The method converges quickly, and after two iterations the mirror surface figure had improved by a factor of 7. The surface roughness evolves with increasing Cr thickness and deteriorates the quality of subsequent multilayer coatings. The mirror curvature can change upon coating, which complicates the interpretation of the surface metrology data. In this context, the role of layer stress is discussed. Potential improvements of the process are also proposed.
1 January 2021 in Journal of Synchrotron Radiation
Multilayer (ML) based x-ray optics have gained considerable interest at 3rd generation synchrotron light sources. Over the last 20 years, more than 200 devices have been fabricated at the ESRF ML Laboratory and deployed on ESRF beamlines, mainly in two configurations: as Kirkpatrick-Baez (KB) focusing devices and as double-bounce high-flux monochromators. The KB mirrors are either bent or polished to their elliptical figure. The ML coatings require steep meridional thickness gradients to account for the variable angle of reflection along the beam footprint. The increased incident angles as compared to total reflection mirrors provide larger numerical apertures and therefore smaller diffraction limited focal spots. At present, ESRF KB optics reach spot sizes down to about 12 nm and are being operated up to photon energies of 65 keV. Double ML monochromators (DMM) are an interesting alternative to double crystal monochromators (DCM) whenever high flux rather than high spectral resolution is required. On many new ESRF beamlines, monochromators with bandwidths between 0.1% and 0.5% are part of the optics layout. The production of efficient DMMs with such narrow bandwidths is challenging since it implies a large number of bi-layers and low d-spacings. Possible thickness variations in depth and along the beam footprint must remain within these tolerances in order not to spoil their performance. Recently installed DMMs achieve a spectral resolution better than 0.4% and a total transmission above 50%. This paper will recall some fundamental design aspects for ML x-ray optics and show examples of applications on ESRF beamlines. It will address present limitations and discuss possible approaches to improve the ML performance.