Fabrizio Renno

Prof. Fabrizio Renno


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in International Journal on Interactive Design and Manufacturing (IJIDeM)
Verified
Journal Article
Closed access
PDF file
Antonio LanzottiAntonio Lanzotti
Antonio Lanzotti
FCFrancesco Carbone
Francesco Carbone
SGStanislao Grazioso
Stanislao Grazioso
FRFabrizio Renno
Fabrizio Renno
MSMichele Staiano
Michele Staiano

15 May 2019 in International Journal on Interactive Design and Manufacturing (IJIDeM)
Verified
Journal Article
Closed access
PDF file
Antonio LanzottiAntonio Lanzotti
Antonio Lanzotti
MCMauro Calise
Mauro Calise
MMMaddalena Molaro
Maddalena Molaro
SPStefano Papa
Stefano Papa
SPStanislao Patalano
Stanislao Patalano
FRFabrizio Renno
Fabrizio Renno

Verified
Journal Article
Open access
PDF file
Roberta GasparroRoberta Gasparro
Roberta Gasparro
FRFabrizio Renno
Fabrizio Renno
SVSimone De Vita
Simone De Vita
Antonio LanzottiAntonio Lanzotti
Antonio Lanzotti
Massimo MartorelliMassimo Martorelli
Massimo Martorelli
PIETRO AUSIELLOPIETRO AUSIELLO
PIETRO AUSIELLO
Background/Objectives: One of the most serious complications following implant placement in the atrophic posterior mandible is injury to the inferior alveolar nerve (IAN), which can also happen during occlusal loading of the implants. This study investigates the effects of 4 mm implant stress transmission to the inferior alveolar nerve during occlusal loading in cases of severe posterior mandibular atrophy. Methods: The computer-aided design (CAD) model was created and modified through Direct Modeling techniques. The structure of cortical and trabecular bones was simplified, and it was modeled as a cylinder block. Finite element analysis (FEA) was carried out in 3D to investigate the pressure distribution over the IAN at different implant-to-nerve distances (1.5 mm, 0.5 mm, and 0.1 mm), and stress and strain deformations were simulated in the mandibular model. Results: The results of the pressure analysis on the inferior alveolar nerve indicate that the pressure distribution at different implant-to-nerve distances (1.5 mm, 0.5 mm, and 0.1 mm) is consistently below 0.026 MPa, which corresponds to the maximum pressure range that may block nerve impulses. This occurs even at the theoretical and simulated distance of 0.1 mm, suggesting that cortical bone stiffness plays a crucial role in mitigating stress at reduced implant-to-nerve proximities. Conclusions: Within the limits of this study, ultra-short implants can be placed even less than 0.5 mm (up to 0.1 mm under the 3D-FEA hypothesis) above the inferior alveolar nerve under the 3D-FEA hypothesis, while maintaining pressure below the threshold value. This is due to the rigidity of the cortical bone, which helps to reduce pressure transmission to the nerve. These findings may expand the indications for ultra-short implants, even in mandibles with a residual bone height of just 4 mm.

12 October 2020 in International Journal on Interactive Design and Manufacturing (IJIDeM)
Verified
Journal Article
Open access
PDF file
FRFabrizio Renno
Fabrizio Renno
FBF. Barbato
F. Barbato
GBG. Barbarino
G. Barbarino
DMDomenico Marzullo
Domenico Marzullo
RGR. Guida
R. Guida
SPS. Papa
S. Papa
Main targets of this activity research are the making and the optimization of new detectors by means of the Systems Engineering methods. With the observation of the gravitational wave event of August 17th, 2017 and then with those of the extragalactic neutrino of September 22nd, the Multimessenger Astrophysics era began. It is a new way of exploring the Universe, powered by globally coordinated observations of several experiments. So, new X and gamma rays’ detectors solutions are needed in order to provide competitive results in the energy range 10 keV–10 meV. Here is briefly described how the Systems Engineering can improve the development of the proposal of a new technique: The Crystal Eye, a wide field of view detector with a good spatial resolution obtained thanks to a high pixelation.

25 September 2022
Verified
Book Chapter
Closed access
PDF file
FRFabrizio Renno
Fabrizio Renno
SPStefano Papa
Stefano Papa
RPRosario Polichetti
Rosario Polichetti
DCDomenico Coccorese
Domenico Coccorese
RDRaffaele D’aNgelo
Raffaele D’aNgelo
Antonio LanzottiAntonio Lanzotti
Antonio Lanzotti

1 December 2021
Verified
Book Chapter
Closed access
PDF file
FRFabrizio Renno
Fabrizio Renno
SPStefano Papa
Stefano Papa
DMDomenico Marzullo
Domenico Marzullo
FBFelicia Carla Tiziana Barbato
Felicia Carla Tiziana Barbato
GBGiancarlo Barbarino
Giancarlo Barbarino