Simone De Vita

Dr. Simone De Vita

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Roberta GasparroRoberta Gasparro
Roberta Gasparro
FRFabrizio Renno
Fabrizio Renno
SVSimone De Vita
Simone De Vita
Antonio LanzottiAntonio Lanzotti
Antonio Lanzotti
Massimo MartorelliMassimo Martorelli
Massimo Martorelli
PIETRO AUSIELLOPIETRO AUSIELLO
PIETRO AUSIELLO
Background/Objectives: One of the most serious complications following implant placement in the atrophic posterior mandible is injury to the inferior alveolar nerve (IAN), which can also happen during occlusal loading of the implants. This study investigates the effects of 4 mm implant stress transmission to the inferior alveolar nerve during occlusal loading in cases of severe posterior mandibular atrophy. Methods: The computer-aided design (CAD) model was created and modified through Direct Modeling techniques. The structure of cortical and trabecular bones was simplified, and it was modeled as a cylinder block. Finite element analysis (FEA) was carried out in 3D to investigate the pressure distribution over the IAN at different implant-to-nerve distances (1.5 mm, 0.5 mm, and 0.1 mm), and stress and strain deformations were simulated in the mandibular model. Results: The results of the pressure analysis on the inferior alveolar nerve indicate that the pressure distribution at different implant-to-nerve distances (1.5 mm, 0.5 mm, and 0.1 mm) is consistently below 0.026 MPa, which corresponds to the maximum pressure range that may block nerve impulses. This occurs even at the theoretical and simulated distance of 0.1 mm, suggesting that cortical bone stiffness plays a crucial role in mitigating stress at reduced implant-to-nerve proximities. Conclusions: Within the limits of this study, ultra-short implants can be placed even less than 0.5 mm (up to 0.1 mm under the 3D-FEA hypothesis) above the inferior alveolar nerve under the 3D-FEA hypothesis, while maintaining pressure below the threshold value. This is due to the rigidity of the cortical bone, which helps to reduce pressure transmission to the nerve. These findings may expand the indications for ultra-short implants, even in mandibles with a residual bone height of just 4 mm.

2 December 2025 in Oral
Verified
Journal Article
Open access
PDF file
Francesco PuleioFrancesco Puleio
Francesco Puleio
FSFabio Salmeri
Fabio Salmeri
ELEttore Lupi
Ettore Lupi
IUInes Urbano
Ines Urbano
Roberta GasparroRoberta Gasparro
Roberta Gasparro
RGRoberto Lo Giudice
Roberto Lo Giudice
Background: The precision of intraoral scanners (IOSs) is a key factor in ensuring the reliability of digital impressions, particularly in full-arch workflows. Although proprietary metrology tools are generally employed for scanner validation, open-source platforms could provide a cost-effective alternative for clinical research. Methods: This in vivo study compared the precision of two IOSs—3Shape TRIOS 3 and Planmeca Emerald S—using an open-source analytical workflow based on Autodesk Meshmixer and CloudCompare. A single healthy subject underwent five consecutive full-arch scans per device. Digital models were trimmed, aligned by manual landmarking and iterative closest-point refinement, and analyzed at six deviation thresholds (<0.01 mm to <0.4 mm). The percentage of surface points within clinically acceptable limits (<0.3 mm) was compared using paired t-tests. Results: TRIOS 3 exhibited significantly higher repeatability than Planmeca Emerald S (p < 0.001). At the <0.3 mm threshold, 99.3% ± 0.4% of points were within tolerance for TRIOS 3 versus 92.9% ± 6.8% for Planmeca. At the <0.1 mm threshold, values were 89.6% ± 5.7% and 47.3% ± 13.7%, respectively. Colorimetric deviation maps confirmed greater spatial consistency of TRIOS 3, particularly in posterior regions. Conclusions: Both scanners achieved clinically acceptable precision for full-arch impressions; however, TRIOS 3 demonstrated superior repeatability and lower variability. The proposed open-source workflow proved feasible and reliable, offering an accessible and reproducible method for IOS performance assessment in clinical settings.