Purpose: The relationship between retinal morphology, as assessed by optical coherence tomography (OCT), and retinal function in microperimetry (MP) has not been well studied, despite its increasing importance as an essential functional endpoint for clinical trials and emerging therapies in retinal diseases. Normative databases of healthy ageing eyes are largely missing from literature.Methods: Healthy subjects above 50 years were examined using two MP devices, MP‐3 (NIDEK) and MAIA (iCare). An identical grid, encompassing 45 stimuli was used for retinal sensitivity (RS) assessment. Deep‐learning‐based algorithms performed automated segmentation of ellipsoid zone (EZ), outer nuclear layer (ONL), ganglion cell layer (GCL) and retinal nerve fibre layer (RNFL) from OCT volumes (Spectralis, Heidelberg). Pointwise co‐registration between each MP stimulus and corresponding location on OCT was performed via registration algorithm. Effect of age, eccentricity and layer thickness on RS was assessed by mixed effect models.Results: Three thousand six hundred stimuli from twenty eyes of twenty patients were included. Mean patient age was 68.9 ± 10.9 years. Mean RS for the first exam was 28.65 ± 2.49 dB and 25.5 ± 2.81 dB for MP‐3 and MAIA, respectively. Increased EZ thickness, ONL thickness and GCL thickness were significantly correlated with increased RS (all p < 0.001). Univariate models showed lower RS with advanced age and higher eccentricity (both p < 0.05).Conclusion: This work provides reference values for healthy age‐related EZ and ONL‐thicknesses without impairment of visual function and evidence for RS decrease with eccentricity and increasing age. This information is crucial for interpretation of future clinical trials in disease.
Age-related macular degeneration (AMD) is a leading cause of blindness in the developed world. Due to an aging population, its prevalence is expected to increase, making novel and optimized therapy options imperative. However, both late-stage forms of the disease, neovascular AMD (nAMD) and geographic atrophy (GA), exhibit considerable variability in disease progression and treatment response, complicating the evaluation of therapeutic efficacy and making it difficult to design clinical trials that are both inclusive and statistically robust. Traditional trial designs frequently rely on generalized endpoints that may not fully capture the nuanced benefits of treatment, particularly in diseases like GA, where functional improvements can be gradual or subtle. Artificial intelligence (AI) has the potential to address these issues by identifying novel, condition-specific biomarkers or endpoints, enabling precise patient stratification and improving recruitment strategies. By providing an overview of the advances and application of AI-based optical coherence tomography analysis in the context of AMD clinical trials, this review highlights the transformative potential of AI in optimizing clinical trial outcomes for patients with nAMD or GA secondary to AMD.
Microperimetry (MP) has emerged as a clinical functional endpoint in nonexudative age-related macular degeneration (AMD). In this study, we aim to provide reference values for test-retest outcomes on two MP devices in intermediate AMD (iAMD). Prospective, cross-sectional study. 3 600 stimuli from 20 eyes in 20 subjects. Patients diagnosed with iAMD underwent consecutive testing on MP-3 (NIKED, Gamagori, Japan) and MAIA (CenterVue Icare, Padova, Italy). The obtained point-wise sensitivity (PWS) measurements were superimposed with optical coherence tomography (OCT) (Spectralis, Heildelberg Engineering) acquired. Hyperreflective foci (HRF), drusen volume, ellipsoid zone (EZ)-thickness and outer nuclear layer (ONL)-thickness were quantified with deep-learning algorithms. Subretinal drusenoid deposits (SDD) were manually annotated. We assessed test-retest repeatability at the location of these biomarkers using Bland-Altmann coefficients of repeatability. Furthermore, interdevice correlation, fixation stabilities, and examination durations were evaluated. Comparable overall point-wise retest variances were detected for MP-3 (±4.54 dB) and MAIA (±5.24 dB). SDDs led to significantly worse repeatability in the MAIA device (p = 0.03). Drusen, HRF, EZ-thickness, and ONL thickness had no significant impact on test-retest variance. A good intradevice correlation (MP-3: 0.869 [0.851 - 0.886] MAIA 0.848 [0.827 - 0.867]), and a good mean interdevice correlation (0.841 [0.819 - 0.861]) was observed. Intradevice and interdevice repeatability for MP examinations with MP-3 and MAIA in patients with iAMD can be considered as good. Biomarkers except for SDD show no significant impact in repeatability in both devices. This supports MP as a reliable functional endpoint in clinical trials in iAMD.
To compare functional parameters between healthy aged eyes and different stages of age-related macular degeneration (AMD) based on functional parameters in microperimetry (MP) in 2 commonly used MP devices. A prospective, cross-sectional study. From 80 eyes from 80 subjects, 14 400 stimuli points were included. Subjects classified as healthy, intermediate AMD, neovascular AMD (nAMD), or geographic atrophy (GA) secondary to AMD were imaged with Spectralis HRA+OCT (Heidelberg Engineering) and underwent 2 consecutive examinations each, using the MP-3 (NIDEK) under photopic conditions and the MAIA (Centervue) under mesopic conditions. Pointwise sensitivity (PWS), mean sensitivity, range between highest and lowest PWS, fixation stability, and examination duration were compared between all 4 groups in both devices. Group comparison was performed using linear mixed-effects models and a discriminant analysis to find the parameters that best discriminated the respective AMD stage. Pointwise sensitivity, range of the PWS, fixation metrics, and durations of the examinations. The groups exhibited significant differences in PWS (P < 0.001) and mean sensitivity (P < 0.001), with healthy eyes showing the highest and late stages of AMD showing the lowest sensitivity values. In addition, GA showed significantly greater fixation stability compared with nAMD in the MP-3 at 2° and 4° (P = 0.014 and P = 0.008, respectively). The examination duration in healthy patients was significantly shorter compared with patients with GA (P = 0.041) in MP-3. No significant differences in fixation stability and duration between groups were observed with the MAIA device. The range between the highest and lowest PWS was the most effective parameter for discrimination, with a classification accuracy of 52.5% and 50.6% in the MP-3 and MAIA, respectively. Retinal sensitivity declines with disease progression in AMD in both mesopic and photopic background illumination. The lowest retinal sensitivity was observed in patients with GA. Background illumination should be considered when selecting an MP device for a clinical trial. Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Purpose: To define interdevice differences in quantitative outer retinal biomarkers across three spectral‐domain (SD) optical coherence tomography (OCT) devices in geographic atrophy (GA). Methods: Patients with GA prospectively underwent imaging using Spectralis (Heidelberg Engineering), Cirrus (Zeiss) and Maestro (Topcon) OCT devices. Ellipsoid zone (EZ) and outer nuclear layer (ONL) thickness, as well as EZ and retinal pigment epithelium (RPE) loss, were automatically pre‐segmented and manually corrected. Quantitative measurements were compared between OCT devices using anova or Friedman tests. Bland–Altman analysis determined mean differences and 95% limits of agreement (LoA). Results: A total of 7080 B‐scans from 120 OCT volumes of 40 eyes were analysed. Mean patient age was 80 ± 7 years. Mean EZ thickness in the 6‐mm macular cube was 34.8 ± 4.6, 33.4 ± 4.1 and 31.0 ± 4.8 μm for Spectralis, Cirrus and Maestro, respectively, while mean ONL thickness was 77.8 ± 9.2, 78.5 ± 9.4 and 75.8 ± 9.6 μm. Interdevice differences were significant for EZ and ONL‐thickness (all p < 0.05). Mean EZ thickness bias ranged from 1.5 to 3.8 μm, with the widest LoA between Spectralis and Maestro. Mean ONL‐thickness bias ranged from −0.7 to 2.7 μm, with the widest LoA between Cirrus and Maestro. EZ‐loss and EZ/RPE‐loss‐area also differed significantly (both p < 0.01). Conclusion: Visualization and quantification of atrophic features at the level of the photoreceptors, including EZ thickness, EZ loss and ONL thickness, are influenced by the implemented OCT machine. Consistency in the OCT device during patient monitoring allows for the highest precision and eliminates interdevice differences in quantitative outcome measures.