The paper focuses on the analysis of initiation and propagation of CO2 corrosion in several samples of low-alloy steel with different microstructures using scanning electrochemical microscopy (SECM) and other microscopy techniques. It is found that the corrosion rate and the mode of corrosion are highly sensitive to the microstructure. The overall current density is much higher and more uniformly distributed for the tempered martensite structure than for samples having either a ferritic-pearlitic microstructure or a microstructure combining ferritic, bainitic and martensitic-austenitic regions. As a result, the sample with the tempered martensite structure undergoes uniform corrosion, while the other two samples undergo selective corrosion. The SECM maps show that regions of polygonal ferrite generate larger anodic currents than the pearlitic structure in the early stages of corrosion. The residual cementite provides greater cathodic surface areas after the initial dissolution of ferritic lamellae within pearlite, promoting galvanic corrosion and subsequently enhanced dissolution of ferritic lamellae. According to SECM data, the dissolution of iron in polygonal ferritic grains is 2.4 times faster than that of ferritic lamellae in pearlitic regions.
Low alloy steel samples with different Cr content (0‒3 wt%) have been exposed to simulated well environment. It is revealed that the 3%Cr sample initially has the highest corrosion resistance. However, due to faster formation of a FexCayCO3 protective scale in the 0%Cr sample, this sample demonstrates the highest corrosion resistance after 2 days of exposure. While the FexCayCO3 scale is also formed in the 1%Cr sample, the scale is weakly adhered and porous, which does not enable good corrosion resistance. Although the scale formation is delayed in a sample with 3 wt%Cr, once it is formed, the presence of Cr-rich phase in this scale provides greater long-term corrosion protection. Localized corrosion attack is observed in the samples with 0% Cr and 1%Cr, whereas the 3%Cr sample shows no sign of localized attack due to initial pre-passivation and the ability to rebuild the protective scale.