OBJECTIVES: Our goal was to analyse the initial results of the first 50 transapical transcatheter mitral valve-in-valve procedures performed in a single Latin American centre. METHODS: A prospective, single centre, database analysis was conducted to evaluate immediate, 30-day and 1-year postoperative results of 50 consecutive patients who had a transcatheter mitral valve-in-valve procedure from May 2015 to June 2018. All patients were operated on in a hybrid operating room and received a balloon-expandable valve via the transapical approach. Preoperative and postoperative characteristics were analysed and compared between the first 25 and the second 25 patients to evaluate the impact of the learning curve. Twenty patients had a follow-up examination at 1 year. RESULTS: There was a 98% device success rate. The patients had a mean age of 64.8 years; 72% were women; 80% were in New York Heart Association functional class ≥III preoperatively; and 36% of the procedures were urgent. The mean Society of Thoracic Surgeons scores and EuroSCORE II were 8.3% and 12.4%, respectively. Patients had a median of 2 previous operations; valve durability was 12.1 years; and 64% mitral valve disease of rheumatic fever aetiology. Echocardiography showed decreases in the maximum and mean mitral gradients from 23.5 to 14.6 and 11.5 to 6.4 mmHg postoperatively; the overall mean hospitalization period was 15 days. The overall mortality rate at 30 days was 14%, with 1 intraprocedural death. Further subanalyses between the first and the second half of the cases showed a drop in the mortality rate from 20% to 8% (P < 0.01). CONCLUSION: The transcatheter mitral valve-in-valve procedure was shown to be a safe and effective procedure to treat bioprosthetic dysfunction, with potential benefits in patients with rheumatic disease.
1 January 2018 in Brazilian Journal of Cardiovascular Surgery
Objective: To analyze the behavior of platelets after transcatheter valve-in-valve implantation for the treatment of degenerated bioprosthesis and how they correlate with adverse events upon follow-up. Methods: Retrospective analysis of 28 patients who received a valve-in-valve implant, 5 in aortic, 18 in mitral and 5 in tricuspid positions. Data were compared with 74 patients submitted to conventional redo valvular replacements during the same period, and both groups' platelet curves were analyzed. Statistical analysis was conducted using the IBM SPSS Statistics (R) 20 for Windows. Results: All patients in the valve-in-valve group developed thrombocytopenia, 25% presenting mild (<150.000/mu L), 54% moderate (<100.000/mu L) and 21% severe (50%. Conclusion: Although thrombocytopenia is an extremely common finding after valve-in-valve procedures, the degree of platelet count drop did not correlate with greater incidence of postoperative adverse outcomes in our study population.
8 September 2020 in Interactive CardioVascular and Thoracic Surgery
OBJECTIVES: Concomitant valvular heart valve disease is a frequent finding, with higher morbidity and mortality among patients undergoing redo surgical procedures. Our goal was to report our initial experience with combined transcatheter Inovare bioprosthesis implants for severe valve dysfunction. METHODS: Among 300 transcatheter procedures, a total of 6 patients had concurrent simultaneous transcatheter bioprosthesis implants for severe mitral bioprosthesis failure (valve-in-valve), with a second valve procedure that included native aortic (n = 2) or degenerated bioprostheses in the aortic position (n = 4). During the procedures, all patients were treated with a balloon-expandable Inovare transcatheter valve, using the transapical approach. RESULTS: Patients were highly symptomatic [New York Heart Association (NYHA) functional class IV: 100%], with a mean age of 62 ± 5 years, yielding a mean European System for Cardiac Operative Risk II (EuroSCORE II) of 24.0 ± 10.1%. There was a mean of 1.6 ± 0.4 prior valve operations/patient, with a median time from prior mitral bioprosthesis surgery of 13.0 (9.2–20.0) years. Device success was 100% according to the Mitral Valve Academic Research Consortium and the Valve Academic Research Consortium-2 criteria. During the hospital stay, only 1 patient required dialysis, and the median intensive care unit and hospital lengths of stay were 5.0 (3.2–6.7) days and 16.0 (12.2–21.2) days, respectively. No deaths occurred at 30 days; at a median follow-up of 287 (194–437) days, 1 patient died of a non-cardiac cause and the rest of patients were in NYHA functional class I or II, with normofunctioning bioprostheses. CONCLUSIONS: Transcatheter double valve interventions using the Inovare bioprosthesis in this initial series were shown to be a reasonable alternative to redo surgical operations. The short- and mid-term clinical and echocardiographic outcomes demonstrate promising results, although future studies with a larger number of patients and longer follow-up are warranted.
3 March 2026 in Annals of Thoracic Surgery Short Reports
Background: Repeat cardiac operations carry increased risk of morbidity and mortality due to adhesions between the heart and adjacent structures, which increase the complexity of redo sternotomy and the potential for reentry injury. Preoperative CT imaging has been associated with a decreased risk for reentry injury. Methods: We present a series of two cases of complex thorax reentry in which a stepwise sternotomy approach enabled safe reentry. Results: Both patients tolerated the procedure well, with successful orthotopic heart transplantation in each case. A thorough review of the preoperative CT imaging enabled surgical planning to safely navigate structures at high risk for reentry injury. Conclusions: This series demonstrates the utility of two-stage sternotomy in complex thorax reentry cases and the importance of preoperative imaging for the safe surgical planning of such an approach.
1 January 2017 in Brazilian Journal of Cardiovascular Surgery
Objective: To present the results of a new experimental device developed to facilitate the transapical access in endovascular treatment of structural heart diseases. It aims to reduce the risk of bleeding and complications in this type of access and demonstrate the device as a safe, fast and effective alternative. Methods: CorPoint is composed of three parts: introducer, base with coiled spring, and closing capsule. By rotating movements, the spring is introduced into the myocardium and progressively approaches the base to the surface of the heart. Guidewires and catheters are inserted through the hollow central part and, at the end of the procedure, the capsule is screwed over the base, therefore stopping any bleeding. Results: The device was implanted in 15 pigs, weighing 60 kg each, through an anterolateral thoracotomy, while catheters were introduced and guided by fluoroscopy. All animals had minimal bleeding; introducers with diameter up to 22 Fr were used and various catheters and guidewires were easily handled. After finishing the procedure, the closing capsule was attached and no bleeding was observed at the site. Conclusion: This new device has proved effective, fast and secure for the transapical access. This shows great potential for use, especially by ensuring an easier and direct access to the mitral and aortic valves; the shortest distance to be traveled by catheters; access to the ascending and descending aorta; decreased bleeding complications; decreased surgical time; and the possibility of allowing the technique to evolve and become totally percutaneous.