Gabriel Chiritoi

Dr. Gabriel Chiritoi


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2020 in Molecules
Verified
Journal Article
Open access
PDF file
GMGeorge Mogildea
George Mogildea
MMMarian Mogildea
Marian Mogildea
Cristina Popa (Achim)Cristina Popa (Achim)
Cristina Popa (Achim)
GCGabriel Chiritoi
Gabriel Chiritoi
This paper focuses on the dissociation of carbon dioxide (CO2) following the absorption processes of microwave radiation by noncontact metal wire (tungsten). Using a microwave plasma generator (MPG) with a single-mode cavity, we conducted an interaction of microwaves with a noncontact electrode in a CO2 atmosphere. High energy levels of electromagnetic radiation are generated in the focal point of the MPG’s cylindrical cavity. The metal wires are vaporized and ionized from this area, subsequently affecting the dissociation of CO2. The CO2 dissociation is highlighted through plasma characterization and carbon monoxide (CO) quantity determination. For plasma characterization, we used an optical emission spectroscopy method (OES), and for CO quantity determination, we used a gas analyzer instrument. Using an MPG in the CO2 atmosphere, we obtained a high electron temperature of the plasma and a strong dissociation of CO2. After 20 s of the interaction between microwaves and noncontact electrodes, the quantity of CO increased from 3 ppm to 1377 ppm (0.13% CO). This method can be used in space applications to dissociate CO2 and refresh the atmosphere of closed spaces.

Verified
Journal Article
Open access
PDF file
MMMarian Mogildea
Marian Mogildea
GMGeorge Mogildea
George Mogildea
IZIon Sorin Zgura
Ion Sorin Zgura
GCGabriel Chiritoi
Gabriel Chiritoi
CICristian Ionescu
Cristian Ionescu
Catalin-Daniel CONSTANTINESCUCatalin-Daniel CONSTANTINESCU
Catalin-Daniel CONSTANTINESCU
This research highlights the different behaviors of titanium (Ti) wires under the action of 500 W and 800 W microwave power levels. Following the interaction between microwaves and a titanium wire placed in the node of the (TM011—transverse magnetic mode) waveguide in air at atmospheric pressure, plasma was generated. Using optical emission spectroscopy technique it was observed that during plasma generation at 500 W and 800 W microwaves powers, metallic ions, and gas ions were created, and the plasmas fulfilled the local thermodynamic equilibrium (LTE) conditions. The XRD analysis showed that on the surface of the Ti wire exposed to 500 W microwave power a mixture of titanium dioxide (TiO2) and titanium oxide (TiO) grew, while the Ti wire exposed to 800 W microwave power was completely vaporized and a mixture of TiO2 and TiO nanoparticles was synthesized. The SEM analysis showed that the dimensions of the titanium oxide (TiOx) nanoparticles generated by both microwave discharges ranged from 5 nm to 200 nm. The results of EDS analysis showed that the power of microwaves plays an important role in quantitative conversion from Ti wire into a TiOx mixture. The TEM analysis indicates that most of the nanoparticles are either amorphous or nanocrystalline. Using this simple and inexpensive technique one can grow a TiOx layer on the surface of titanium electrodes or can synthetize nanocrystalline TiOx particles.

2 October 2017 in arXiv
Verified
Preprint
Open access
PDF file
GCGabriel Chiritoi
Gabriel Chiritoi
EPE. M. Popescu
E. M. Popescu
ARA. A. Radu
A. A. Radu
ACA. Caramete
A. Caramete
LCL. Caramete
L. Caramete
AEA. Enuica
A. Enuica
We present a novel methodology for the operation of macroscopic Kelvin Probe instruments. The methodology is based on the use of a harmonic backing potential signal to drive the tip-sample variable capacitance and on a Fourier representation of the tip current, allows for the operation of the instrument under full control and improves its scanning performance by a factor of 60 or more over that of currently available commercial instruments.

31 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
GCGabriel Chiritoi
Gabriel Chiritoi
EPEugeniu Mihnea Popescu
Eugeniu Mihnea Popescu
This work presents the development and experimental characterization of a compact ultraviolet (UV) telescope based on silicon photomultipliers (SiPMs) designed for the detection of faint atmospheric optical tracks. Such transient optical phenomena include meteors, transient luminous events (TLEs), space debris reentries, and other faint atmospheric emissions. Nuclearite-induced atmospheric emission is considered as a benchmark case for evaluating the expected signal levels of rare luminous track events. We detail the fabrication, assembly, and testing of the SiPM sensor array, comprising parallel Geiger-mode avalanche diodes with high fill factor and photon detection efficiency, alongside custom readout electronics using self-triggering ASICs, precision optical components, and a stable mechanical mount. This photon-counting telescope provides a compact and mechanically robust alternative to conventional PMT-based systems, with demonstrated capability for detecting low-light atmospheric tracks under controlled laboratory conditions.