Matias Alberto Bossio

Dr. Matias Alberto Bossio

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Alexandre Presas BatlloAlexandre Presas Batllo
Alexandre Presas Batllo
DVDavid Valentin
David Valentin
EEEduard Egusquiza
Eduard Egusquiza
CVCarme Valero
Carme Valero
MEMonica Egusquiza
Monica Egusquiza
MBMatias Alberto Bossio
Matias Alberto Bossio
To accurately determine the dynamic response of a structure is of relevant interest in many engineering applications. Particularly, it is of paramount importance to determine the Frequency Response Function (FRF) for structures subjected to dynamic loads in order to avoid resonance and fatigue problems that can drastically reduce their useful life. One challenging case is the experimental determination of the FRF of submerged and confined structures, such as hydraulic turbines, which are greatly affected by dynamic problems as reported in many cases in the past. The utilization of classical and calibrated exciters such as instrumented hammers or shakers to determine the FRF in such structures can be very complex due to the confinement of the structure and because their use can disturb the boundary conditions affecting the experimental results. For such cases, Piezoelectric Patches (PZTs), which are very light, thin and small, could be a very good option. Nevertheless, the main drawback of these exciters is that the calibration as dynamic force transducers (relationship voltage/force) has not been successfully obtained in the past. Therefore, in this paper, a method to accurately determine the FRF of submerged and confined structures by using PZTs is developed and validated. The method consists of experimentally determining some characteristic parameters that define the FRF, with an uncalibrated PZT exciting the structure. These parameters, which have been experimentally determined, are then introduced in a validated numerical model of the tested structure. In this way, the FRF of the structure can be estimated with good accuracy. With respect to previous studies, where only the natural frequencies and mode shapes were considered, this paper discuss and experimentally proves the best excitation characteristic to obtain also the damping ratios and proposes a procedure to fully determine the FRF. The method proposed here has been validated for the structure vibrating in air comparing the FRF experimentally obtained with a calibrated exciter (impact Hammer) and the FRF obtained with the described method. Finally, the same methodology has been applied for the structure submerged and close to a rigid wall, where it is extremely important to not modify the boundary conditions for an accurate determination of the FRF. As experimentally shown in this paper, in such cases, the use of PZTs combined with the proposed methodology gives much more accurate estimations of the FRF than other calibrated exciters typically used for the same purpose. Therefore, the validated methodology proposed in this paper can be used to obtain the FRF of a generic submerged and confined structure, without a previous calibration of the PZT.

1 August 2017 in Journal of Fluids and Structures
Verified
Journal Article
Open access
MBMatias Alberto Bossio
Matias Alberto Bossio
DVDavid Valentín
David Valentín
Alexandre Presas BatlloAlexandre Presas Batllo
Alexandre Presas Batllo
DMDavid Ramos Martin
David Ramos Martin
EEEduard Egusquiza
Eduard Egusquiza
MEMonica Egusquiza
Monica Egusquiza

1 November 2016 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
DVDavid Valentin
David Valentin
DRDavid Ramos
David Ramos
MBMatias Alberto Bossio
Matias Alberto Bossio
Alexandre Presas BatlloAlexandre Presas Batllo
Alexandre Presas Batllo
EEEduard Egusquiza
Eduard Egusquiza
CVCarme Valero
Carme Valero
Natural frequencies estimation of Francis turbines is of paramount importance in the stage of design in order to avoid vibration and resonance problems especially during transient events. Francis turbine runners are submerged in water and confined with small axial and radial gaps which considerably decrease their natural frequencies in comparison to the same structure in the air. Acoustic-structural FSI simulations have been used to evaluate the influence of these gaps. This model considers an entire prototype of a Francis turbine, including generator, shaft, runner and surrounding water. The radial gap between the runner and the static parts has been changed from the real configuration (about 0.04% the runner diameter) to 1% of the runner diameter to evaluate its influence on the machine natural frequencies. Mode-shapes and natural frequencies of the whole machine are discussed for all the boundary conditions tested.

4 April 2017 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
CVC Valero
C Valero
EEEduard Egusquiza
Eduard Egusquiza
Alexandre Presas BatlloAlexandre Presas Batllo
Alexandre Presas Batllo
DVDavid Valentin
David Valentin
MEMonica Egusquiza
Monica Egusquiza
MBMatias Alberto Bossio
Matias Alberto Bossio
The fast change in new renewable energy is affecting directly the required operating range of hydropower plants. According to the present demand of electricity, it is necessary to generate different levels of power. Because of its ease to regulate and its huge storage capacity of energy, hydropower is the unique energy source that can adapt to the demand. Today, the required operating range of turbine units is expected to extend from part load to overload. These extreme operations points can cause several pressure pulsations, cavitation and vibrations in different parts of the machine. To determine the effects on the machine, vibration measurements are necessary in actual machines. Vibrations can be used for machinery protection and to identify problems in the machine (diagnosis). In this paper, some results obtained in a hydropower plant are presented. The variation of global levels and vibratory signatures has been analysed as function as gross head, transducer location and operating points.

22 November 2023 in Energies
Verified
Journal Article
Open access
PDF file
RBRaquel Busqué
Raquel Busqué
MBMatias Alberto Bossio
Matias Alberto Bossio
ABAlbert Brigido
Albert Brigido
ALAntoni Lara
Antoni Lara
This paper investigates the effects of different channel geometries on the performance of Proton Exchange Membrane Fuel Cells (PEMFCs). The study employs computational fluid dynamics (CFD) coupled with thermal and electrochemical simulations to analyze five channel geometries (cases A to E) of bipolar plates. A thorough study on this topic is not found in the literature and aims to identify designs that optimize performance and align with cost-effective production methods. Among the various studied geometries, case D, featuring a trapezoidal cross-section, exhibited the most favorable performance compared to the others, with a current density value of 2.01 A/cm2 and a maximum temperature of 74.89 °C at 0.3 V, leading to an increase in generated power of 4.46%, compared to base case A. The trapezoidal shape enhanced the contact area with the reacting region, resulting in higher reaction rates and an improved overall performance. However, the study also highlights the relevance of velocity and turbulence, with case B demonstrating an enhanced performance due to its higher velocity, and case E benefiting from localized higher velocity regions and turbulence created by baffles. Case B can increase generated power at its peak by around 3.21%, and case E can improve it by 1.29%, with respect to case A. These findings underscore that contact area has a major impact on the PEMFC performance, but velocity and turbulence also play relevant roles. Additionally, trapezoidal channels can be easily manufactured through sheet metal-forming techniques, aligning well with new market trends of weight and cost reduction on bipolar plates. Fuel and oxygen utilization percentages, 38.14% and 62.96% at 0.3 V, respectively, further confirm the superiority of trapezoidal channels, providing insights into optimizing the PEMFC performance. This exhaustive study contributes valuable information for designing efficient metallic bipolar plates and advancing the development of practical fuel cell technologies.

4 April 2017 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
DVDavid Valentin
David Valentin
Alexandre Presas BatlloAlexandre Presas Batllo
Alexandre Presas Batllo
EEEduard Egusquiza
Eduard Egusquiza
CVCarme Valero
Carme Valero
MBMatias Alberto Bossio
Matias Alberto Bossio
Studying the dynamic response of Francis turbine runners is of paramount importance in order to avoid resonance problems during operating conditions. For this purpose, the natural frequencies as well as their associated mode-shapes and damping ratios of the runner have to be determined. In this paper, an Experimental Modal Analysis (EMA) of the runner of a Francis turbine prototype has been performed. By means of this experimental technique, natural frequencies, mode-shapes and damping ratios have been estimated in air. Results obtained have been compared with a Finite Element Method (FEM) model in order to check the accuracy of the simulation.