Robin Remus

Mr. Robin Remus

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RRRobin Remus
Robin Remus
ALAndreas Lipphaus
Andreas Lipphaus
MNMarc Neumann
Marc Neumann
BBBeate Bender
Beate Bender
In computational biomechanics, two separate types of models have been used predominantly to enhance the understanding of the mechanisms of action of the lumbosacral spine (LSS): Finite element (FE) and musculoskeletal multibody (MB) models. To combine advantages of both models, hybrid FE-MB models are an increasingly used alternative. The aim of this paper is to develop, calibrate, and validate a novel passive hybrid FE-MB open-access simulation model of a ligamentous LSS using ArtiSynth. Based on anatomical data from the Male Visible Human Project, the LSS model is constructed from the L1-S1 rigid vertebrae interconnected with hyperelastic fiber-reinforced FE intervertebral discs, ligaments, and facet joints. A mesh convergence study, sensitivity analyses, and systematic calibration were conducted with the hybrid functional spinal unit (FSU) L4/5. The predicted mechanical responses of the FSU L4/5, the lumbar spine (L1-L5), and the LSS were validated against literature data from in vivo and in vitro measurements and in silico models. Spinal mechanical responses considered when loaded with pure moments and combined loading modes were total and intervertebral range of motions, instantaneous axes and centers of rotation, facet joint contact forces, intradiscal pressures, disc bulges, and stiffnesses. Undesirable correlations with the FE mesh were minimized, the number of crisscrossed collagen fiber rings was reduced to five, and the individual influences of specific anatomical structures were adjusted to in vitro range of motions. Including intervertebral motion couplings for axial rotation and nonlinear stiffening under increasing axial compression, the predicted kinematic and structural mechanics responses were consistent with the comparative data. The results demonstrate that the hybrid simulation model is robust and efficient in reproducing valid mechanical responses to provide a starting point for upcoming optimizations and extensions, such as with active skeletal muscles.

27 September 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
RRRobin Remus
Robin Remus
SSSascha Selkmann
Sascha Selkmann
ALAndreas Lipphaus
Andreas Lipphaus
MNMarc Neumann
Marc Neumann
BBBeate Bender
Beate Bender
Most spine models belong to either the musculoskeletal multibody (MB) or finite element (FE) method. Recently, coupling of MB and FE models has increasingly been used to combine advantages of both methods. Active hybrid FE-MB models, still rarely used in spine research, avoid the interface and convergence problems associated with model coupling. They provide the inherent ability to account for the full interplay of passive and active mechanisms for spinal stability. In this paper, we developed and validated a novel muscle-driven forward dynamic active hybrid FE-MB model of the lumbosacral spine (LSS) in ArtiSynth to simultaneously calculate muscle activation patterns, vertebral movements, and internal mechanical loads. The model consisted of the rigid vertebrae L1-S1 interconnected with hyperelastic fiber-reinforced FE intervertebral discs, ligaments, facet joints, and force actuators representing the muscles. Morphological muscle data were implemented via a semi-automated registration procedure. Four auxiliary bodies were utilized to describe non-linear muscle paths by wrapping and attaching the anterior abdominal muscles. This included an abdominal plate whose kinematics was optimized using motion capture data from upper body movements. Intra-abdominal pressure was calculated from the forces of the abdominal muscles compressing the abdominal cavity. For the muscle-driven approach, forward dynamics assisted data tracking was used to predict muscle activation patterns that generate spinal postures and balance the spine without prescribing accurate spinal kinematics. During calibration, the maximum specific muscle tension and spinal rhythms resulting from the model dynamics were evaluated. To validate the model, load cases were simulated from −10° extension to +30° flexion with weights up to 20 kg in both hands. The biomechanical model responses were compared with in vivo literature data of intradiscal pressures, intra-abdominal pressures, and muscle activities. The results demonstrated high agreement with this data and highlight the advantages of active hybrid modeling for the LSS. Overall, this new self-contained tool provides a robust and efficient estimation of LSS biomechanical responses under in vivo similar loads, for example, to improve pain treatment by spinal stabilization therapies.

5 September 2025 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
LCLinda Carpenedo
Linda Carpenedo
DIDominika Ignasiak
Dominika Ignasiak
RRRobin Remus
Robin Remus
LBLuigi La Barbera
Luigi La Barbera
Understanding spine biomechanics is essential for maintaining posture under static and dynamic conditions, relying on a balance of muscular and gravitational forces. Computational musculoskeletal (MSK) models are increasingly being used in biomechanical research as non-invasive alternatives to in vivo and in vitro methods. Two main MSK modeling strategies are multibody (MB) models, which simplify the spine using rigid vertebrae and intervertebral joints to study muscle recruitment, and finite element (FE) models, which provide detailed tissue representation but often rely on oversimplified loading conditions. Recently, coupled (C) models integrating MB and FE approaches have emerged, though they face technical integration challenges. This literature review examines thoracolumbar MSK modeling methods—MB, FE, and C—to outline current practices, evaluate model capabilities, and inform future research and development. Most reviewed models have been published since 2016, reflecting the growing interest and advances in computational spine biomechanics. While certain modeling choices (e.g., the representation of body weight) are consistent across studies, considerable variability remains in other aspects (e.g., the depiction of muscular architecture, including the selection of muscle groups and the number of fascicles used). Despite being critical for model credibility, validation is often constrained by the limited availability of experimental data. Finally, the review highlights emerging directions such as modeling more complex functional tasks, personalizing anatomical and mechanical properties, and promoting Open Science to enhance reproducibility and collaboration in the field.

24 May 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
RRRobin Remus
Robin Remus
CSChristian Sure
Christian Sure
SSSascha Selkmann
Sascha Selkmann
EUEike Uttich
Eike Uttich
BBBeate Bender
Beate Bender
Simulations of human-technology interaction in the context of product development require comprehensive knowledge of biomechanical in vivo behavior. To obtain this knowledge for the abdomen, we measured the continuous mechanical responses of the abdominal soft tissue of ten healthy participants in different lying positions anteriorly, laterally, and posteriorly under local compression depths of up to 30 mm. An experimental setup consisting of a mechatronic indenter with hemispherical tip and two time-of-flight (ToF) sensors for optical 3D displacement measurement of the surface was developed for this purpose. To account for the impact of muscle tone, experiments were conducted with both controlled activation and relaxation of the trunk muscles. Surface electromyography (sEMG) was used to monitor muscle activation levels. The obtained data sets comprise the continuous force-displacement data of six abdominal measurement regions, each synchronized with the local surface displacements resulting from the macro-indentation, and the bipolar sEMG signals at three key trunk muscles. We used inverse finite element analysis (FEA), to derive sets of nonlinear material parameters that numerically approximate the experimentally determined soft tissue behaviors. The physiological standard values obtained for all participants after data processing served as reference data. The mean stiffness of the abdomen was significantly different when the trunk muscles were activated or relaxed. No significant differences were found between the anterior-lateral measurement regions, with exception of those centered on the linea alba and centered on the muscle belly of the rectus abdominis below the intertubercular plane. The shapes and areas of deformation of the skin depended on the region and muscle activity. Using the hyperelastic Ogden model, we identified unique material parameter sets for all regions. Our findings confirmed that, in addition to the indenter force-displacement data, knowledge about tissue deformation is necessary to reliably determine unique material parameter sets using inverse FEA. The presented results can be used for finite element (FE) models of the abdomen, for example, in the context of orthopedic or biomedical product developments.

1 January 2018 in Proceedings of the Design 2018 15th International Design Conference
Verified
Conference Paper
Closed access
MBMarcel Bartz
Marcel Bartz
RGRainer Gößling
Rainer Gößling
RRRobin Remus
Robin Remus
BBBeate Bender
Beate Bender
In recent years, bioinspired lightweight design has become a high priority in technology. An important source is the musculoskeletal system, which achieves a light construction by the interplay of different effects, which have the aim of minimizing bending stresses. In this paper the potentials for technology and the challenges for a transfer are discussed using kinematic chains as an example. An iterative approach is presented, which represents a solution to integrate the simultaneous optimization process of the musculoskeletal system into the technical product development process.

7 April 2020 in Zeitschrift für wirtschaftlichen Fabrikbetrieb
Verified
Journal Article
Closed access
MNMarc Neumann
Marc Neumann
RRRobin Remus
Robin Remus
MSMaike Sauerhoff
Maike Sauerhoff
Andreas LipphausAndreas Lipphaus
Andreas Lipphaus
EUEike Uttich
Eike Uttich
BBBeate Bender
Beate Bender
Kurzfassung: Der Digitale Zwilling gewinnt in der Produktentwicklung zunehmend an Bedeutung. Während der Fokus bislang auf der digitalen Abbildung von Eigenschaften technischer Produkte oder Prozesse liegt, greift diese Interpretation für solche Systeme zu kurz, die mit dem Menschen interagieren. Im vorliegenden Beitrag werden anhand ausgewählter Forschungsprojekte Potentiale der Kopplung menschbezogener Modelle mit Digitalen Zwillingen aufgezeigt und aktuelle Herausforderungen diskutiert.