Aneta Kania

Dr. Aneta Kania

Silesian University of Technology
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2021 in Coatings
Verified
Journal Article
Open access
PDF file
AKAneta Kania
Aneta Kania
Magdalena Monika SzindlerMagdalena Monika Szindler
Magdalena Monika Szindler
Marek SzindlerMarek Szindler
Marek Szindler
Magnesium alloys have been investigated as temporary biomaterials for orthopedic applications. Despite their high osseointegration and mechanical (bone-like) properties, Mg alloys quickly degrade in simulated physiological media. Surface coatings can be deposited onto Mg alloys to slow the corrosion rate of these biomaterials in chloride-rich environments. TiO2 films show high potential for improving the corrosion resistance of magnesium alloys. This article presents the structural observations and corrosion behavior of TiO2 thin films deposited onto a MgCa2Zn1Gd3 alloy using atomic layer deposition (ALD). Surface morphologies were observed using scanning electron microscopy (SEM) and atomic force microscopy (AFM), and Raman analysis of the deposited TiO2 films was also carried out. The corrosion behavior of the uncoated alloy and the alloy coated with TiO2 was measured in Ringer’s solution at 37 °C using electrochemical and immersion tests. The microscopic observations of the TiO2 thin films with a thickness of about 52.5 and 70 nm showed that the surface morphology was homogeneous without visible defects on the TiO2 surface. The electrochemical and immersion test results showed that the thin films decreased the corrosion rate of the studied Mg-based alloy, and the corrosion resistance was higher in the thicker TiO2 film.

1 May 2020 in Thin Solid Films
Verified
Journal Article
Closed access
AKAneta Kania
Aneta Kania
WPWirginia Pilarczyk
Wirginia Pilarczyk
MSMagdalena M. Szindler
Magdalena M. Szindler

31 May 2019 in Materials
Verified
Journal Article
Open access
PDF file
AKAneta Kania
Aneta Kania
RNRyszard Nowosielski
Ryszard Nowosielski
AGAgnieszka Gawlas-Mucha
Agnieszka Gawlas-Mucha
RBRafał Babilas
Rafał Babilas
Magnesium alloys with rare earth metals are very attractive materials for medical application because of satisfactory mechanical properties. Nevertheless, low corrosion resistance is an obstacle in the use of Mg alloys as resorbable orthopedic implants. The paper presents results of mechanical and corrosion properties of MgCa5-xZn1Gdx (x = 1, 2, and 3 wt. %) alloys. Based on the microscopic observations it was stated that the studied alloys show a dendritic microstructure with interdendritic solute rich regions. The phase analysis reveals an occurrence of α-Mg and Mg2Ca, Ca2Mg6Zn3 phases that are thermodynamic predictions, and stated Mg26Zn59Gd7 phases in MgCa5-xZn1Gdx (x = 1, 2, and 3 wt. %) alloys. The Mg26Zn59Gd7 phases are visible as lamellar precipitations along interdendritic regions. It was confirmed that an increase of Gd content from 1 to 3 wt. % improves ultimate tensile (Rm; from 74 to 89 MPa) and compressive strength (Rc; from 184 to 221 MPa). Moreover, the studied alloys are active in Ringer’s solution. They are characterized by an increase of corrosion potential (Ecorr) of about 150 mV in comparison with values of open circuit potential (EOCP). The best electrochemical parameters (e.g., corrosion current density, icorr, polarization resistance, Rp, and Ecorr) were obtained for the MgCa3Zn1Gd2 alloy.

1 May 2018 in Journal of Non-Crystalline Solids
Verified
Journal Article
Closed access
RBRafał Babilas
Rafał Babilas
Anna BajorekAnna Bajorek
Anna Bajorek
Piotr SakiewiczPiotr Sakiewicz
Piotr Sakiewicz
AKAneta Kania
Aneta Kania
DSDawid Szyba
Dawid Szyba

6 July 2024 in Materials
Verified
Journal Article
Open access
PDF file
AKAneta Kania
Aneta Kania
Magdalena Monika SzindlerMagdalena Monika Szindler
Magdalena Monika Szindler
Marek SzindlerMarek Szindler
Marek Szindler
Zbigniew BrytanZbigniew Brytan
Zbigniew Brytan
WLWojciech Lonski
Wojciech Lonski
Magnesium and its alloys are attractive temporary implants due to their biocompatibility and biodegradability. Moreover, Mg has good mechanical and osteoinductive properties. But magnesium and Mg alloys have one significant disadvantage: poor corrosion resistance in a physiological environment. Hence, a deposition of various layers on the surface of Mg alloys seems to be a good idea. The purpose of the article is to analyze the structure and morphology of two MgCa2Zn1 and MgCa2Zn1Gd3 alloys coated by SnO2 ALD (atomic layer deposition) films of various thickness. The studies were performed using scanning electron microscopy (SEM), X-ray fluorescence (XRF), and an X-ray diffractometer. The corrosion activity of the thin films and substrate alloys in a chloride-rich Ringer’s solution at 37 °C was also observed. The corrosion tests that include electrochemical, immersion measurements, and electrochemical impedance spectroscopy (EIS) were evaluated. The results indicated that SnO2 had a heterogeneous crystal structure. The surfaces of the thin films were rough with visible pores. The corrosion resistance of SnO2 measured in all corrosion tests was higher for the thicker films. The observations of corrosion products after immersion tests indicated that they were lamellar-shaped and mainly contained Mg, O, Ca, and Cl in a lower concentration.

28 February 2020 in Materials
Verified
Journal Article
Open access
PDF file
AKAneta Kania
Aneta Kania
PNPiotr Nolbrzak
Piotr Nolbrzak
ARAdrian Radoń
Adrian Radoń
ANAleksandra Niemiec-Cyganek
Aleksandra Niemiec-Cyganek
RBRafał Babilas
Rafał Babilas
This article discusses the influence of the thickness of TiO2 films deposited onto MgCa2Zn1 and MgCa2Zn1Gd3 alloys on their structure, corrosion behavior, and cytotoxicity. TiO2 layers (about 200 and 400 nm thick) were applied using magnetron sputtering, which provides strong substrate adhesion. Such titanium dioxide films have many attractive properties, such as high corrosion resistance and biocompatibility. These oxide coatings stimulate osteoblast adhesion and proliferation compared to alloys without the protective films. Microscopic observations show that the TiO2 surface morphology is homogeneous, the grains have a spherical shape (with dimensions from 18 to 160 nm). Based on XRD analysis, it can be stated that all the studied TiO2 layers have an anatase structure. The results of electrochemical and immersion studies, performed in Ringer’s solution at 37 °C, show that the corrosion resistance of the studied TiO2 does not always increase proportionally with the thickness of the films. This is a result of grain refinement and differences in the density of the titanium dioxide films applied using the physical vapor deposition (PVD) technique. The results of 24 h immersion tests indicate that the lowest volume of evolved H2 (5.92 mL/cm2) was with the 400 nm thick film deposited onto the MgCa2Zn1Gd3 alloy. This result is in agreement with the good biocompatibility of this TiO2 film, confirmed by cytotoxicity tests.