Rana Jafari

Dr. Rana Jafari


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2026 in Optics
Verified
Journal Article
Open access
PDF file
PAPedram Abdolghader
Pedram Abdolghader
RJRana Jafari
Rana Jafari
ADAbinash Das
Abinash Das
BBBilol Banerjee
Bilol Banerjee
ECElouan Crews
Elouan Crews
RTRick P. Trebino
Rick P. Trebino
We present a method for quantifying ultrashort pulse-shape instability in a train of pulses using multi-shot second-harmonic-generation frequency-resolved optical gating (SHG FROG). All versions of multi-shot FROG have previously shown the ability to qualitatively distinguish stable from unstable pulse trains, as systematic differences appear between measured and retrieved FROG traces when instability is present. This has proved possible because the recently introduced retrieved-amplitude N-grid algorithmic (RANA) approach provides highly reliable pulse retrieval, even for unstable pulse trains and in the presence of noise, thereby eliminating the possibility that algorithm stagnation, which also yields such systematic differences, could be confused for such instability. In other words, RANA’s excellent performance ensures that any non-random discrepancies between measured and retrieved FROG traces reflect physical pulse-shape instability rather than algorithmic stagnation. To quantify such instability, we now introduce an instability parameter, R. It involves an extension of the well-known statistical “Runs” test, which has been used for decades to test for systematic error in fits to one-dimensional (1D) data. A runs test counts the “runs”—consecutive points in the plot of the difference between the data and fit with the same sign (+ or −), yielding an evaluation of the goodness of the fit, largely independent of random error. Specifically, the more runs, the better the fit. However, because FROG traces are functions of two variables, we must extend the usual 1D runs test to two dimensions, that is, to enumerate the 2D runs—“hills” and “valleys” in the difference between measured and retrieved 2D FROG traces. Many small 2D runs indicate only random noise-like differences, that is, a good fit, and, hence, a stable pulse train, whereas few large runs reflect systematic error, that is, a poor fit, and, hence, pulse-shape instability. Finally, because random noise could contribute numerous meaningless runs in the wings of a FROG trace, where the intensity is near zero, we must also weight each hill and valley by its average measured trace intensity in order to minimize its effects. We show that R is intuitive and reasonable and, in addition, is independent of pulse complexity and trace size. As a result, it provides a clear metric of pulse-shape stability vs. instability.

28 February 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RJRana Jafari
Rana Jafari
EGElizabeth S. Grace
Elizabeth S. Grace
RTRick P. Trebino
Rick P. Trebino
Devices that measure the presence of instability in the pulse shapes in trains of ultrashort laser pulses do not exist, so this task necessarily falls to pulse-measurement devices, like Frequency-Resolved Optical Gating (FROG) and its variations, which have proven to be a highly reliable class of techniques for measuring stable trains of ultrashort laser pulses. Fortunately, multi-shot versions of FROG have also been shown to sensitively distinguish trains of stable from those of unstable pulse shapes by displaying readily visible systematic discrepancies between the measured and retrieved traces in the presence of unstable pulse trains. However, the effects of pulse-shape instability and algorithm stagnation can be indistinguishable, so a never-stagnating algorithm—even when instability is present—is required and is generally important. In previous work, we demonstrated that our recently introduced Retrieved-Amplitude N-grid Algorithmic (RANA) approach produces highly reliable (100%) pulse-retrieval in the second-harmonic-generation (SHG) version of FROG for thousands of sample trains of pulses with stable pulse shapes. Further, it does so even for trains of unstable pulse shapes and thus both reliably distinguishes between the two cases and provides a rough measure of the degree of instability as well as a reasonable estimate of most typical pulse parameters. Here, we perform the analogous study for the polarization-gating (PG) and transient-grating (TG) versions of FROG, which are often used for higher-energy pulse trains. We conclude that PG and TG FROG, coupled with the RANA approach, also provide reliable indicators of pulse-shape instability. In addition, for PG and TG FROG, the RANA approach provides an even better estimate of a typical pulse in an unstable pulse train than SHG FROG does, even in cases of significant pulse-shape instability.

25 May 2022
Verified
Conference Paper
Closed access
MSMark Schittenhelm
Mark Schittenhelm
RJRana Jafari
Rana Jafari
GGGeorge Gibson
George Gibson
RTRick P. Trebino
Rick P. Trebino
SKSoroush Khosravi
Soroush Khosravi
Ambiguity Removal of Two-Color SHG-FROG Traces by Time Seperation |