Pedram Abdolghader

Dr. Pedram Abdolghader


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2021 in Optics Express
Verified
Journal Article
Closed access
PAPedram Abdolghader
Pedram Abdolghader
ARAndrew Ridsdale
Andrew Ridsdale
TGTassos Grammatikopoulos
Tassos Grammatikopoulos
GRGavin Resch
Gavin Resch
FLFrançois Légaré
François Légaré
ITIsaac Tamblyn
Isaac Tamblyn
Hyperspectral stimulated Raman scattering (SRS) microscopy is a label-free technique for biomedical and mineralogical imaging which can suffer from low signal-to-noise ratios. Here we demonstrate the use of an unsupervised deep learning neural network for rapid and automatic denoising of SRS images: UHRED (Unsupervised Hyperspectral Resolution Enhancement and Denoising). UHRED is capable of “one-shot” learning; only one hyperspectral image is needed, with no requirements for training on previously labelled datasets or images. Furthermore, by applying a k-means clustering algorithm to the processed data, we demonstrate automatic, unsupervised image segmentation, yielding, without prior knowledge of the sample, intuitive chemical species maps, as shown here for a lithium ore sample.

17 June 2024 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Open access
MIMaksym Ivanov
Maksym Ivanov
ÉDÉtienne Doiron
Étienne Doiron
MSMarco Scaglia
Marco Scaglia
PAPedram Abdolghader
Pedram Abdolghader
GTGabriel Tempea
Gabriel Tempea
BSBruno E. Schmidt
Bruno E. Schmidt
Ultrafast laser science witnesses a transformative change due to the introduction of robust, high repetition rate Yb based solid state lasers. We prove the ability of hollow-core fiber (HCF) post compression to keep pace with the constantly raising average powers and pulse energies provided by state-of-the-art lasers. Over a wide range of input parameters, HCFs can provide high transmissions in the 80%–90% range with greater than 10-fold compression. First, we describe a double stage HCF setup that compresses 80 W, 2 mJ, 338 fs pulses centered at 1030 nm down to sub-two optical cycles (6 fs FWHM) with 56 W output power. This 56-fold pulse compression is paired with an overall throughput of 70% and very good long term stability (1.5% StDev over 8 hours). Next, power scaling to 300 W with variable pulse energy and repetition rate (from 100 kHz, 3 mJ to 25 kHz, 12 mJ) is presented. We compressed 1.3 ps pulses of down to 100 fs in a single HCF at 300 W level. Finally, we reveal the potential of utilizing the ultrabroadband HCF output as a spectroscopy platform that can provide various, simultaneous outputs covering a wavelength range from 430 nm up to 12 $\mu$ m.

8 May 2025 in Optics Letters
Verified
Journal Article
Closed access
PDF file
AMAlexander R. Meadows
Alexander R. Meadows
KYKiyoshi Yamamoto
Kiyoshi Yamamoto
IGIvan Graumann
Ivan Graumann
FSFrancisco Szlafsztein
Francisco Szlafsztein
Vladimir ChvykovVladimir Chvykov
Vladimir Chvykov
JRJorge J. Rocca
Jorge J. Rocca
We demonstrate the scaling of few-cycle post-compression to the multi-TW regime by producing 15 mJ, 6.9 fs pulses through spectral broadening of 800 nm light in a large-bore (⊘1 mm) hollow-capillary fiber (HCF) of 5 m in length. The good beam quality allows for focusing of the beam to near diffraction limit to achieve a peak intensity of 6.5 · 1018 W/cm2 for relativistic laser–matter interaction studies. The performance of the helium-filled HCF is characterized under various operating conditions. We find that a reverse pressure gradient allows for operation above the critical power for self-focusing with >88% transmission for input energies of 23 mJ.

3 June 2026 in Optics
Verified
Journal Article
Open access
PDF file
PAPedram Abdolghader
Pedram Abdolghader
RJRana Jafari
Rana Jafari
ADAbinash Das
Abinash Das
BBBilol Banerjee
Bilol Banerjee
ECElouan Crews
Elouan Crews
RTRick P. Trebino
Rick P. Trebino
We present a method for quantifying ultrashort pulse-shape instability in a train of pulses using multi-shot second-harmonic-generation frequency-resolved optical gating (SHG FROG). All versions of multi-shot FROG have previously shown the ability to qualitatively distinguish stable from unstable pulse trains, as systematic differences appear between measured and retrieved FROG traces when instability is present. This has proved possible because the recently introduced retrieved-amplitude N-grid algorithmic (RANA) approach provides highly reliable pulse retrieval, even for unstable pulse trains and in the presence of noise, thereby eliminating the possibility that algorithm stagnation, which also yields such systematic differences, could be confused for such instability. In other words, RANA’s excellent performance ensures that any non-random discrepancies between measured and retrieved FROG traces reflect physical pulse-shape instability rather than algorithmic stagnation. To quantify such instability, we now introduce an instability parameter, R. It involves an extension of the well-known statistical “Runs” test, which has been used for decades to test for systematic error in fits to one-dimensional (1D) data. A runs test counts the “runs”—consecutive points in the plot of the difference between the data and fit with the same sign (+ or −), yielding an evaluation of the goodness of the fit, largely independent of random error. Specifically, the more runs, the better the fit. However, because FROG traces are functions of two variables, we must extend the usual 1D runs test to two dimensions, that is, to enumerate the 2D runs—“hills” and “valleys” in the difference between measured and retrieved 2D FROG traces. Many small 2D runs indicate only random noise-like differences, that is, a good fit, and, hence, a stable pulse train, whereas few large runs reflect systematic error, that is, a poor fit, and, hence, pulse-shape instability. Finally, because random noise could contribute numerous meaningless runs in the wings of a FROG trace, where the intensity is near zero, we must also weight each hill and valley by its average measured trace intensity in order to minimize its effects. We show that R is intuitive and reasonable and, in addition, is independent of pulse complexity and trace size. As a result, it provides a clear metric of pulse-shape stability vs. instability.

1 August 2025 in APL Photonics
Verified
Journal Article
Open access
PAPedram Abdolghader
Pedram Abdolghader
MSMarco Scaglia
Marco Scaglia
ÉDÉtienne Doiron
Étienne Doiron
MIMaksym Ivanov
Maksym Ivanov
MBMadhu Beniwal
Madhu Beniwal
BSBruno E. Schmidt
Bruno E. Schmidt
We present a robust approach capable of generating ultrashort pulses in the visible (VIS) spectral range through second-harmonic generation of broadened pulses centered at around 1030 nm. Tunable VIS pulses with durations as short as 10 fs, sub-20 fs, and sub-50 fs across the 420–600 nm range are achieved by spectrally broadening the 1030 nm output employing a dual-stage hollow-core fiber setup, followed by frequency doubling in cascaded beta barium borate (β-BaB2O4, BBO) crystals. The system delivers pulse energies ranging from a few to above hundred microjoules at repetition rates ranging between 10 and 100 kHz, while maintaining excellent beam quality and power stability over several hours of continuous operation. These characteristics make the source highly suitable for applications in ultrafast spectroscopy, nonlinear optics, and strong-field physics.