Objective: The goal of the present study was to investigate the clinical utility of measurements of ear-canal reflectance (ECR) in a population of patients with conductive hearing loss in the presence of an intact, healthy tympanic membrane and an aerated middle ear. We also sought to compare the diagnostic accuracy of umbo velocity (VU) measurements and measurements of ECR in the same group of patients. Design: This prospective study comprised 31 adult patients with conductive hearing loss, of which 14 had surgically confirmed stapes fixation due to otosclerosis, 6 had surgically confirmed ossicular discontinuity, and 11 had computed tomography and vestibular evoked myogenic potential confirmed superior semicircular canal dehiscence (SCD). Measurements on all 31 ears included pure-tone audiometry for 0.25 to 8 kHz, ECR for 0.2 to 6 kHz using the Mimosa Acoustics HearID system, and VU for 0.3 to 6 kHz using the HLV-1000 laser Doppler vibrometer (Polytec Inc, Waldbronn, Germany). We analyzed power reflectance |ECR|2 as well as the absorbance level = 10 × log10(1 − |ECR|2). All measurements were made before any surgical intervention. The VU and ECR data were plotted against normative data obtained in a companion study of 58 strictly defined normal ears (Rosowski et al., 2011). Results: Small increases in |ECR|2 at low-to-mid frequencies (400–1000 Hz) were observed in cases with stapes fixation, while narrowband decreases were seen for both SCD and ossicular discontinuity. The SCD and ossicular discontinuity differed in that the SCD had smaller decreases at mid-frequency (∼1000 Hz), whereas ossicular discontinuity had larger decreases at lower frequencies (500–800 Hz). SCD tended to have less air-bone gap at high frequencies (1–4 kHz) compared with stapes fixation and ossicular discontinuity. The |ECR|2 measurements, in conjunction with audiometry, could successfully separate 28 of the 31 cases into the three pathologies. By comparison, VU measurements, in conjunction with audiometry, could successfully separate various pathologies in 29 of 31 cases. Conclusions: The combination of |ECR|2 with audiometry showed clinical utility in the differential diagnosis of conductive hearing loss in the presence of an intact tympanic membrane and an aerated middle ear and seems to be of similar sensitivity and specificity to measurements of VU plus audiometry. Additional research is needed to expand upon these promising preliminary results.
Objective: This study compares measurements of ear-canal reflectance (ECR) to other objective measurements of middle ear function including audiometry, umbo velocity (VU), and tympanometry in a population of strictly defined normal-hearing ears. Design: Data were prospectively gathered from 58 ears of 29 normal-hearing subjects, 16 females and 13 males, aged 22 to 64 yr. Subjects met all of the following criteria to be considered as having normal hearing: (1) no history of significant middle ear disease; (2) no history of otologic surgery; (3) normal tympanic membrane on otoscopy; (4) pure-tone audiometric thresholds of 20 dB HL or better for 0.25 to 8 kHz; (5) air-bone gaps no greater than 15 dB at 0.25 kHz and 10 dB for 0.5 to 4 kHz; (6) normal, type-A peaked tympanograms; and (7) all subjects had two “normal” ears (as defined by these criteria). Measurements included pure-tone audiometry for 0.25 to 8 kHz, standard 226 Hz tympanometry, ECR for 0.2 to 6 kHz at 60 dB SPL using the Mimosa Acoustics HearID system, and umbo velocity (VU) for 0.3 to 6 kHz at 70 to 90 dB SPL using the HLV-1000 laser Doppler vibrometer (Polytec Inc). Results: Mean power reflectance (|ECR|2) was near 1.0 at 0.2 to 0.3 kHz, decreased to a broad minimum of 0.3 to 0.4 between 1 and 4 kHz, and then sharply increased to almost 0.8 by 6 kHz. The mean pressure reflectance phase angle (∠ECR) plotted on a linear frequency scale showed a group delay of approximately 0.1 msec for 0.2 to 6 kHz. Small significant differences were observed in |ECR|2 at the lowest frequencies between right and left ears and between males and females at 4 kHz. |ECR|2 decreased with age but reached significance only at 1 kHz. Our ECR measurements were generally similar to previous published reports. Highly significant negative correlations were found between |ECR|2 and VU for frequencies below 1 kHz. Significant correlations were also found between the tympanometrically determined peak total compliance and |ECR|2 and VU at frequencies below 1 kHz. The results suggest that middle ear compliance contributes significantly to the measured power reflectance and umbo velocity at frequencies below 1 kHz but not at higher frequencies. Conclusions: This study has established a database of objective measurements of middle ear function (ECR, umbo velocity, tympanometry) in a population of strictly defined normal-hearing ears. These data will promote our understanding of normal middle ear function and will serve as a control for comparison to similar measurements made in pathological ears.
Objective: Reflectance measured in the ear canal offers a noninvasive method to monitor the acoustic properties of the middle ear, and few systematic measurements exist on the effects of various middle-ear disorders on the reflectance. This work uses a human cadaver-ear preparation and a mathematical middle-ear model to both measure and predict how power reflectance R is affected by the middle-ear disorders of static middle-ear pressures, middle-ear fluid, fixed stapes, disarticulated incudostapedial joint, and tympanic-membrane perforations. Design: R was calculated from ear-canal pressure measurements made on human-cadaver ears in the normal condition and five states: (1) positive and negative pressure in the middle-ear cavity, (2) fluid-filled middle ear, (3) stapes fixed with dental cement, (4) incudostapedial joint disarticulated, and (5) tympanic-membrane perforations. The middle-ear model of Kringlebotn (1988) was modified to represent the middle-ear disorders. Model predictions are compared with measurements. Results: For a given disorder, the general trends of the measurements and model were similar. The changes from normal in R, induced by the simulated disorder, generally depend on frequency and the extent of the disorder (except for the disarticulation). Systematic changes in middle-ear static pressure (up to 6300 daPa) resulted in systematic increases in R. These affects were most pronounced for frequencies up to 1000 to 2000 Hz. Above about 2000 Hz there were some asymmetries in behavior between negative and positive pressures. Results with fluid in the middle-ear air space were highly dependent on the percentage of the air space that was filled. Changes in R were minimal when a smaller fraction of the air space was filled with fluid, and as the air space was filled with more saline, R increased at most frequencies. Fixation of the stapes generally resulted in a relatively small low-frequency increase in R. Disarticulation of the incus with the stapes led to a consistent low-frequency decrease in R with a distinctive minimum below 1000 Hz. Perforations of the tympanic membrane resulted in a decrease in R for frequencies up to about 2000 Hz; at these lower frequencies, smaller perforations led to larger changes from normal when compared with larger perforations. Conclusions: These preliminary measurements help assess the utility of power reflectance as a diagnostic tool for middle-ear disorders. In particular, the measurements document (1) the frequency ranges for which the changes are largest and (2) the extent of the changes from normal for a spectrum of middle-ear disorders.
1 October 2011 in Journal of Speech, Language, and Hearing Research
Purpose: The purpose of this study was to determine whether the relative fundamental frequency (RFF) surrounding a voiceless consonant in patients with hyperfunctionally related voice disorders would normalize after a successful course of voice therapy. Method: Pre- and posttherapy measurements of RFF were compared in 16 subjects undergoing voice therapy for voice disorders associated with vocal hyperfunction. Results: A 2-way analysis of variance showed a statistically significant effect of both cycle of vibration near the consonant and therapy phase (pre- vs. post-), with p < .001. A post hoc paired Student’s t test showed that posttherapy RFF measurements were significantly higher (more typical; p < .0001) than pretherapy measurements. Conclusions: Prior to therapy, participants exhibited lowered RFF values, similar to those found previously (Stepp, Hillman, & Heaton, 2010). After successful completion of voice therapy, RFF values increased toward patterns seen previously in individuals with healthy typical voice. The goal of voice therapy in these patients was to reduce laryngeal muscle tension; therefore, the increase of RFF toward more typical values may be indicative of decreased baseline laryngeal muscle tension resulting from therapy. Results are discussed further in terms of necessary research to incorporate RFF as a clinical measure of vocal hyperfunction.
17 October 2017 in Journal of Speech, Language, and Hearing Research
Purpose: A frequent complaint by older adults is difficulty communicating in challenging acoustic environments. The purpose of this work was to review and summarize information about how speech perception in complex listening situations changes across the adult age range. Method: This article provides a review of age-related changes in speech understanding in complex listening environments and summarizes results from several studies conducted in our laboratory. Results: Both degree of high frequency hearing loss and cognitive test performance limit individuals' ability to understand speech in difficult listening situations as they age. The performance of middle-aged adults is similar to that of younger adults in the presence of noise maskers, but they experience substantially more difficulty when the masker is 1 or 2 competing speech messages. For the most part, middle-aged participants in studies conducted in our laboratory reported as much self-perceived hearing problems as did older adult participants. Conclusions: Research supports the multifactorial nature of listening in real-world environments. Current audiologic assessment practices are often insufficient to identify the true speech understanding struggles that individuals experience in these situations. This points to the importance of giving weight to patients' self-reported difficulties. Presentation Video: http://cred.pubs.asha.org/article.aspx?articleid=2601619
Objectives: The objective of this work is to determine whether there is a systematic effect of middle ear effusion volume on wideband acoustic immittance in children with surgically confirmed otitis media with effusion. Design: Wideband acoustic immittance was measured in 49 ears from children (9 months to 11 years) who had a diagnosis of otitis media with effusion and compared to 14 ears from children (10 months to 10 years) without a recent history of otitis media. For children with otitis media with effusion, wideband acoustic immittance testing took place in the child’s preoperative waiting room before surgical placement of tympanostomy tubes. Testing was completed in a pressurized condition (wideband tympanometry) for all ears as well as in an ambient condition in a subset of ears. Intraoperative findings regarding effusion volume were reported by the surgeons immediately before tube placement and confirmed following myringotomy. This classified the volume of effusion as compared to middle ear volume categorically as either full, partial, or clear of effusion. The type of wideband acoustic immittance explored in this work was absorbance. Absorbance responses were grouped based on effusion volume into one of four groups: full effusions, partial effusions, ears clear of effusion at the time of surgery, and normal control ears. Standard tympanometry was also completed on all ears. Results: Absorbance is systematically reduced as the volume of the middle ear effusion increases. This reduction is present at most frequencies but is greatest in the frequency range from 1 to 5 kHz. A multivariate logistic regression approach was utilized to classify ears based on effusion volume. The regression approach classified ears as effusion present (full and partial ears) or absent (clear ears and normal control ears) with 100% accuracy, ears with effusion present as either partial or full with 100% accuracy, and ears without effusion as either normal control ears or ears clear of effusion with 75% accuracy. Regression performance was also explored when the dataset was split into a training set (70% of the data) and a validation test set (30% of the data) to simulate how this approach would perform on unseen data in a clinical setting. Accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve are reported. Overall, this approach demonstrates high sensitivity and specificity for classifying ears as effusion being present or absent and as present effusions being full or partial with areas under the curve ranging from 1 to 0.944. Despite the lack of effusion present in both clear ears and normal control ears, this approach was able to distinguish between these ears, but with a more moderate sensitivity and specificity. No systematic effect of effusion volume was found on standard tympanometry. Conclusions: Wideband acoustic immittance, and more specifically, absorbance, is a strong and sensitive indicator of the volume of a middle ear effusion in children with otitis media with effusion.