1 March 2012 in Ear & Hearing
Objective: Reflectance measured in the ear canal offers a noninvasive method to monitor the acoustic properties of the middle ear, and few systematic measurements exist on the effects of various middle-ear disorders on the reflectance. This work uses a human cadaver-ear preparation and a mathematical middle-ear model to both measure and predict how power reflectance R is affected by the middle-ear disorders of static middle-ear pressures, middle-ear fluid, fixed stapes, disarticulated incudostapedial joint, and tympanic-membrane perforations. Design: R was calculated from ear-canal pressure measurements made on human-cadaver ears in the normal condition and five states: (1) positive and negative pressure in the middle-ear cavity, (2) fluid-filled middle ear, (3) stapes fixed with dental cement, (4) incudostapedial joint disarticulated, and (5) tympanic-membrane perforations. The middle-ear model of Kringlebotn (1988) was modified to represent the middle-ear disorders. Model predictions are compared with measurements. Results: For a given disorder, the general trends of the measurements and model were similar. The changes from normal in R, induced by the simulated disorder, generally depend on frequency and the extent of the disorder (except for the disarticulation). Systematic changes in middle-ear static pressure (up to 6300 daPa) resulted in systematic increases in R. These affects were most pronounced for frequencies up to 1000 to 2000 Hz. Above about 2000 Hz there were some asymmetries in behavior between negative and positive pressures. Results with fluid in the middle-ear air space were highly dependent on the percentage of the air space that was filled. Changes in R were minimal when a smaller fraction of the air space was filled with fluid, and as the air space was filled with more saline, R increased at most frequencies. Fixation of the stapes generally resulted in a relatively small low-frequency increase in R. Disarticulation of the incus with the stapes led to a consistent low-frequency decrease in R with a distinctive minimum below 1000 Hz. Perforations of the tympanic membrane resulted in a decrease in R for frequencies up to about 2000 Hz; at these lower frequencies, smaller perforations led to larger changes from normal when compared with larger perforations. Conclusions: These preliminary measurements help assess the utility of power reflectance as a diagnostic tool for middle-ear disorders. In particular, the measurements document (1) the frequency ranges for which the changes are largest and (2) the extent of the changes from normal for a spectrum of middle-ear disorders.
1 May 2010 in Hearing Research
1 July 2013 in Ear & Hearing
Wide band immittance measures can be useful in analyzing acoustic sound flow through the ear and also have diagnostic potential for the identification of conductive hearing loss as well as causes of conductive hearing loss. In order to interpret individual measurements, the variability in test-retest data must be described and quantified. Contributors to variability in ear-canal absorbance-based measurements are described here. These include: assumptions related to methodologies and issues related to the probe fit within the ear and potential acoustic leaks. Evidence suggests that variations in ear-canal cross sectional area or measurement location are small relative to variability within a population. Data are shown to suggest that the determination of the Thévenin equivalent of the ER-10C probe introduces minimal variability and is independent of the foam eartip itself. It is suggested that acoustic leaks in the coupling of the eartip to the ear canal lead to substantial variations and that this issue needs further work in terms of potential criteria to identify an acoustic leak. Additionally, test-retest data from the literature are reviewed.
1 November 2020 in The Journal of the Acoustical Society of America
Wideband acoustic immittance (WAI) measures are noninvasive diagnostic measurements that require an estimate of the ear canal's area at the measurement location. Yet, physical measurements of the area at WAI probe locations are lacking. Methods to measure ear-canal areas from silicone molds were developed and applied to 169 subjects, ages 18–75 years. The average areas at the canal's first bend and at 12 mm insertion depth, which are likely WAI probe locations, were and , respectively. These areas are substantially larger than those assumed by current FDA-approved WAI measurement devices as well as areas estimated with acoustical methods or measured on cadaver ears. Left and right ears from the same subject had similar areas. Sex, height, and weight were not significant factors in predicting area. Age cohort was a significant predictor of area, with area increasing with decade of life. A subset of areas from the youngest female subjects did not show an effect of race on area (White or Chinese). Areas were also measured as a function of insertion depth of 4.8–13.2 mm from the canal entrance; area was largest closest to the canal entrance and systematically decreased with insertion depth.
29 April 2023 in Hearing Research