16 September 2024 in Medical Physics
Verified
Journal Article
Open access
LGLixiang Guo
Lixiang Guo
PMPaul M. Medin
Paul M. Medin
KWKen Kang-Hsin Wang
Ken Kang-Hsin Wang
Background: Ultra‐high dose rate irradiation (≥40 Gy/s, FLASH) has been shown to reduce normal tissue toxicity, while maintaining tumor control compared to conventional dose‐rate radiotherapy. The radiolytic oxygen (O2) depletion (ROD) resulting from FLASH has been proposed to explain the normal tissue protection effect; however, in vivo experiments have not confirmed that FLASH induced global tissue hypoxia. Nonetheless, the experiments reported are based on volume‐averaged measurement, which have inherent limitations in detecting microscopic phenomena, including the potential preservation of stem cells niches due to local FLASH‐induced O2 depletion. Computational modeling offers a complementary approach to understand the ROD caused by FLASH at the microscopic level.Purpose: We developed a comprehensive model to describe the spatial and temporal dynamics of O2 consumption and transport in response to irradiation in vivo. The change of oxygen enhancement ratio (OER) was used to quantify and investigate the FLASH effect as a function of physiological and radiation parameters at microscopic scale.Methods: We considered time‐dependent O2 supply and consumption in a 3D cylindrical geometry, incorporating blood flow linking the O2 concentration ([O2]) in the capillary to that within the tissue through the Hill equation, radial and axial diffusion of O2, metabolic and zero‐order radiolytic O2 consumption, and a pulsed radiation structure. Time‐evolved distributions of [O2] were obtained by numerically solving perfusion‐diffusion equations. The model enables the computation of dynamic O2 distribution and the relative change of OER (δROD) under various physiological and radiation conditions in vivo.Results: Initial [O2] level and the subsequent changes during irradiation determined δROD distribution, which strongly depends on physiological parameters, i.e., intercapillary spacing, ultimately determining the tissue area with enhanced radioresistance. We observed that the δROD/FLASH effect is affected by and sensitive to the interplay effect among physiological and radiation parameters. It renders that the FLASH effect can be tissue environment dependent. The saturation of FLASH normal tissue protection upon dose and dose rate was shown. Beyond ∼60 Gy/s, no significant decrease in radiosensitivity within tissue region was observed. In turn, for a given dose rate, the change of radiosensitivity became saturated after a certain dose level. Pulse structures with the same dose and instantaneous dose rate but with different delivery times were shown to have distinguishable δROD thus tissue sparing, suggesting the average dose rate could be a metric assessing the FLASH effect and demonstrating the capability of our model to support experimental findings.Conclusion: On a macroscopic scale, the modeling results align with the experimental findings in terms of dose and dose rate thresholds, and it also indicates that pulse structure can vary the FLASH effect. At the microscopic level, this model enables us to examine the spatially resolved FLASH effect based on physiological and irradiation parameters. Our model thus provides a complementary approach to experimental methods for understanding the underlying mechanism of FLASH radiotherapy. Our results show that physiological conditions can potentially determine the FLASH efficacy in tissue protection. The FLASH effect may be observed under optimal combination of physiological parameters, not limited to radiation conditions alone.

22 September 2025 in Medical Physics
Verified
Journal Article
Open access
LGLixiang Guo
Lixiang Guo
BZBanghao Zhou
Banghao Zhou
YTYi‐Chun Tsai
Yi‐Chun Tsai
KJKai Jiang
Kai Jiang
VIViktor Iakovenko
Viktor Iakovenko
KWKen Kang-Hsin Wang
Ken Kang-Hsin Wang
Background: The normal tissue sparing effect of ultra‐high dose rate irradiation (≥40 Gy/s, UHDR), as compared to conventional dose rate (CONV), has attracted significant research interest for FLASH radiotherapy (RT). Accurate, dose rate independent, fast‐responding dosimeters capable of resolving the spatiotemporal characteristics of UHDR beams are urgently needed to facilitate FLASH research and support its clinical translation. Tissue‐equivalent scintillators, with millimeter‐level spatial resolution and millisecond‐level temporal resolution, possess these required characteristics and show strong potential for use in UHDR dosimetry. Purpose: We investigated the performance of the HYPERSCINT RP‐FLASH scintillator system at up to 1000 Hz sampling frequency ( f s ) for UHDR electron beam dosimetry. Methods: The scintillator was exposed to CONV and UHDR electron irradiation using a LINAC‐based FLASH platform. Its spectral characteristics were delineated with a four‐component calibration, followed by a signal‐to‐dose calibration using 18 MeV CONV electron beam. The dose linearity and dosimetric accuracy in response to CONV and UHDR irradiation at 1 and 1000 Hz f s were quantified against ion chamber and EBT‐XD film measurements. The response of the scintillator system was investigated as a function of beam energy (6 and 18 MeV), field size (2 × 2 to 25 × 25 cm 2 ), dose per pulse (DPP, 0.8–2.3 Gy/pulse), and pulse repetition frequency (PRF, 30–180 Hz). Relative signal sensitivity was quantified against accumulated dose to account for the scintillator's radiation degradation. Pulse‐resolved dose measurements at 18 MeV UHDR, obtained using the scintillator with 1000 Hz f s for a train of 10 pulses at 180 Hz PRF, were validated with a PMT‐fiber optic scattered radiation detector. Results: The scintillator system at 1 Hz f s demonstrated high accuracy in dose measurements, remaining within 0.5% of ion chamber measurements over the dose range of 0.1–35 Gy under CONV irradiation. For the UHDR irradiation, the scintillator showed <3% dose error compared to film measurements up to 40 Gy at 1000 Hz f s . Its response was found to be minimally dependent on energy, field size, and PRF. The scintillator under‐responded by ∼4% over the 0.8–2.3 Gy/pulse range, although the dose difference relative to film remained within 2%. The radiation degradation of the scintillation detector followed a 2 nd ‐order polynomial fit between 0 and 10 kGy, and a linear fit with a slope of −2.6%/kGy in the range of 0–2 kGy. The pulse‐resolved dose measured by the scintillator was verified to be within 3% accuracy when compared to the measurements obtained using the PMT‐fiber optic detector. Conclusions: With routine dose calibration to account for radiation induced degradation, the fast‐responding scintillator system can accurately provide millisecond‐resolved inter‐pulse measurements for electron beams at conventional and ultra‐high dose rates, with minimal dependence on beam parameters. This suggests that the HYPERSCINT RP‐FLASH scintillator system could serve as a detector of choice for electron FLASH research.

11 November 2025 in Radiation
Verified
Journal Article
Open access
PDF file
BZBanghao Zhou
Banghao Zhou
LGLixiang Guo
Lixiang Guo
WLWeiguo Lu
Weiguo Lu
MRMahbubur Rahman
Mahbubur Rahman
RZRongxiao Zhang
Rongxiao Zhang
KWKen Kang-Hsin Wang
Ken Kang-Hsin Wang
Background: FLASH radiotherapy delivers ultra-high dose rates with normal tissue sparing, but mechanisms remain unclear. We present a streamlined workflow for establishing a LINAC-based electron FLASH (eFLASH) platform in low-resource settings without requiring vendor-proprietary hardware or software, or vendor-assisted modifications to broaden accessibility for FLASH studies. Methods: A LINAC was converted to eFLASH with pulse control and monitoring. Automatic frequency control (AFC) was optimized to stabilize dose per pulse (DPP). Beam data were measured with EBT-XD films, and a Monte Carlo (MC) model was commissioned for in vivo dose calculation. We demonstrated in vivo dosimetry in planning studies of mouse whole-brain and rat spinal cord (C1–T2) irradiation. We further assessed the impact of AFC optimization on the FLASH spinal cord study. Results: AFC optimization stabilized DPP at ~0.6 Gy/pulse, reducing large fluctuations under the default setting. MC agreed with measurements within 2% for PDDs and profiles. MC planning showed uniform whole-brain irradiation with 6 MeV FLASH, while the spinal cord study exhibited up to 10% dose fall-off within 1 cm along the cord, suggesting potential dose-volume effects confounding FLASH sparing. Following AFC optimization, 50% of the C1–T2 cord reached >133 Gy/s, a 23% increase versus default. Conclusions: We demonstrated a cost-effective eFLASH platform and verified its accuracy for preclinical studies, expanding the accessibility of FLASH research.

24 March 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
BZBanghao Zhou
Banghao Zhou
LGLixiang Guo
Lixiang Guo
YTYi-Chun Tsai
Yi-Chun Tsai
AKAlbert van der Kogel
Albert van der Kogel
JWJohn W Wong
John W Wong
KWKen Kang-Hsin Wang
Ken Kang-Hsin Wang
Objective: While FLASH radiotherapy (FLASH-RT) is recognized for normal tissue sparing, its effect in mitigating the toxicity of late-responding organs remains uncertain, limiting clinical adoption. With its clinical importance and steep dose-response, spinal cord is an ideal model for evaluating the FLASH effect on late toxicity. This work introduces a robust image-guided research platform for high-precision irradiation at both conventional (CONV) and ultra-high dose rates (UHDR) to enable FLASH late toxicity studies using a rat spinal cord model. Approach: A modified LINAC was employed to irradiate the C1-T2 rat spinal cord with 18 MeV UHDR and CONV beams. A custom rat immobilization device, a portable X-ray imaging system, and an ion-chamber-based UHDR output monitoring system were integrated to ensure accurate C1-T2 localization and precise dose delivery. A Monte Carlo (MC) dose engine was developed to provide accurate dosimetry and support the interpretation of in vivo results. Scintillator measurements at UHDR were performed within the spinal cord to verify MC results and the precision of our platform. Results: We observed submillimeter deviation in C1–T2 localization between 2D X-ray and 3D CBCT imaging, as well as between pre- and post-irradiation 2D X-ray assessments. Ion chamber readings showed linear correlation with UHDR output (R 2 =1).MC calculations indicated uniform irradiation (<5% non-uniformity) along the central ~13 mm cord, avoiding dose-volume effect. Our CONV beam exhibited dose distribution close to that of the UHDR beam, with difference <3%, isolating dose rate as the only variable. Scintillator measured dose agreed with MC within 4%, with a 100% gamma passing rate (2%/2 mm), confirming both MC accuracy and the platform's high-precision delivery. Significance: We developed the first comprehensive, image-guided preclinical platform for accurate UHDR and CONV irradiation to investigate FLASH-mitigated spinal cord toxicity in rats. This work thus establishes a robust foundation for systematic evaluation of the FLASH effect in late-responding organs and for assessing relevant clinical applicability of FLASH-RT.