Banghao Zhou

Dr. Banghao Zhou


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2024 in arXiv
Verified
Preprint
Open access
PDF file
BZBanghao Zhou
Banghao Zhou
LGLixiang Guo
Lixiang Guo
WLWeiguo Lu
Weiguo Lu
MRMahbubur Rahman
Mahbubur Rahman
RZRongxiao Zhang
Rongxiao Zhang
KWKen Kang-Hsin Wang
Ken Kang-Hsin Wang
Background: FLASH radiotherapy is a treatment regime that delivers therapeutic dose to tumors at an ultra-high dose rate while maintaining adequate normal tissue sparing. However, a comprehensive understanding of the underlying mechanisms, potential late toxicities, and optimal fractionation schemes is important for successful clinical translation. This has necessitated extensive pre-clinical investigations, leading several research institutions to initiate dedicated FLASH research programs. Purpose: This work describes a workflow for establishing an easily accessible electron FLASH (eFLASH) platform. The platform incorporates simplified pulse control, optimized dose rate delivery, and validated Monte Carlo (MC) dose engine for accurate in vivo dosimetry dedicated to FLASH pre-clinical studies. Methods: Adjustment of the automatic frequency control (AFC) module allowed us to optimize the LINAC pulse form to achieve a uniform dose rate. A MC model for the 6 MeV FLASH beam was commissioned to ensure accurate dose calculation necessary for reproducible in vivo studies. Results: Optimizing the AFC module enabled the generation of a uniform pulse form, ensuring consistent dose per pulse and a uniform dose rate throughout FLASH irradiation. The MC model closely agreed with film measurements. MC dose calculations indicated that 6 MeV FLASH is adequate to achieve a uniform dose distribution for mouse whole brain irradiation but may not be optimal for the spinal cord study. Conclusions: We present a novel workflow for establishing a LINAC-based eFLASH research platform, incorporating techniques for optimized dose rate delivery, a simplified pulse control system, and validated MC engine. This work provides researchers with valuable new approaches to facilitate the development of robust and accessible LINAC-based system for FLASH studies.

11 November 2025 in Radiation
Verified
Journal Article
Open access
PDF file
BZBanghao Zhou
Banghao Zhou
LGLixiang Guo
Lixiang Guo
WLWeiguo Lu
Weiguo Lu
MRMahbubur Rahman
Mahbubur Rahman
RZRongxiao Zhang
Rongxiao Zhang
KWKen Kang-Hsin Wang
Ken Kang-Hsin Wang
Background: FLASH radiotherapy delivers ultra-high dose rates with normal tissue sparing, but mechanisms remain unclear. We present a streamlined workflow for establishing a LINAC-based electron FLASH (eFLASH) platform in low-resource settings without requiring vendor-proprietary hardware or software, or vendor-assisted modifications to broaden accessibility for FLASH studies. Methods: A LINAC was converted to eFLASH with pulse control and monitoring. Automatic frequency control (AFC) was optimized to stabilize dose per pulse (DPP). Beam data were measured with EBT-XD films, and a Monte Carlo (MC) model was commissioned for in vivo dose calculation. We demonstrated in vivo dosimetry in planning studies of mouse whole-brain and rat spinal cord (C1–T2) irradiation. We further assessed the impact of AFC optimization on the FLASH spinal cord study. Results: AFC optimization stabilized DPP at ~0.6 Gy/pulse, reducing large fluctuations under the default setting. MC agreed with measurements within 2% for PDDs and profiles. MC planning showed uniform whole-brain irradiation with 6 MeV FLASH, while the spinal cord study exhibited up to 10% dose fall-off within 1 cm along the cord, suggesting potential dose-volume effects confounding FLASH sparing. Following AFC optimization, 50% of the C1–T2 cord reached >133 Gy/s, a 23% increase versus default. Conclusions: We demonstrated a cost-effective eFLASH platform and verified its accuracy for preclinical studies, expanding the accessibility of FLASH research.