In the field of clinical medicine, the real-time monitoring of carbon dioxide (CO2) gas exhaled by the human body is of great significance. At present, the detection devices on the market mainly work by sucking a small amount of gas from the nasal cavity into the detection device, and they present some problems such as overly long sampling tubes, easy blockage or distortion, and an abnormal gas dispersion. In this paper, a micro/nano optical fiber sensor that can directly detect respiration is proposed and is characterized by the relative change in CO2 concentration. The measurement is achieved by using the principle of high evanescent field absorption, and the operating band is 2.004 μm. The sensing effects of micro/nano fibers with different diameters are compared, and the experiment proves that a micro/nano fiber with a diameter of 1 μm can be measured. The light intensity change over 30 s was measured, and the breathing rate was 10–11 times/min. The sensor can achieve a rapid real-time response to CO2 gas detection and is small in size, low-cost, and easy to replace. It has a great application potential in clinical scenarios such as in gastrointestinal endoscopes that require real-time monitoring of human respiration.
Wet etching is the mainstream fabrication method for single-bar quantum cascade lasers (QCLs). Different etching solutions result in varying etching effects on III-V semiconductor materials. In this study, an efficient and nearly ideal etching solution ratio was proposed for simultaneously etching both InP and GaInAs/AlInAs, and the surface chemical reactions induced by each component of the etching solution during the process were investigated. Using univariate and single-component experiments, coupled with various characterization techniques such as atomic force microscopy (AFM), stylus profilometer, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM), we found that the ratio of HBr to hydrogen peroxide significantly determines the etching rate, while the ratio of HCl to hydrogen peroxide affects the interface roughness. The aim of this study was to provide a comprehensive understanding of the effects of different etching solution components, thereby enhancing the understanding of the wet etching process for InP/GaInAs/AlInAs materials. These findings offer valuable insights into efficient QCL fabrication processes and contribute to the advancement of the field.
In the field of clinical medicine, the real-time monitoring of carbon dioxide gas exhaled by the human body is of great significance. At present, the detection devices in the market are mainly detected by sucking a small amount of gas in the nasal cavity to the detection device, and there are some problems such as too long sampling tubes, easy blockage or distortion, and abnormal gas dispersion. In this paper, a micro-nano optical fiber sensor that can directly detect the concentration of end-tidal carbon dioxide is proposed. The measurement is achieved by using the principle of high evanescent field absorption, and the operating band is 2.004 μm. The sensor uses micro-nano optical fiber as the sensing area, and then detects the presence of carbon dioxide gas exhaled by human body through optical power attenuation. The function of micro-nano fiber is to realize the transmission of signal light and also serve as the absorption medium of the gas to be measured. In addition, the variation of light power also reflects the respiratory cycle of the human body. The sensor can realize rapid real-time response to carbon dioxide gas detection, with small size, low cost, and easy to replace. It has great application potential in clinical scenarios such as Gastrointestinal Endoscopes that require real-time monitoring of human respiration.
Wet etching is the mainstream fabrication method for single-bar quantum cascade lasers (QCLs). Different etching solutions result in varying etching effects on III-V semiconductor materials. In this study, an efficient and nearly ideal etching solution ratio was proposed for simultaneously etching both InP and GaInAs/AlInAs, and the surface chemical reactions induced by each component of the etching solution during the process were investigated. Using univariate and single-component experiments, coupled with various characterization techniques such as atomic force microscopy (AFM), stylus profilometer, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM), we found that the ratio of HBr to hydrogen peroxide significantly determines the etching rate, while the ratio of HCl to hydrogen peroxide affects the interface roughness. The aim of this study was to provide a comprehensive understanding of the effects of different etching solution components, thereby enhancing the understanding of the wet etching process for InP/GaInAs/AlInAs materials. These findings offer valuable insights for efficient QCL fabrication processes and contribute to the advancement of the field.