. Joseph W. Tinapple

Dr. . Joseph W. Tinapple


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
SAShashwat Agarwal
Shashwat Agarwal
JHJacob Cozean Holter
Jacob Cozean Holter
TJTravis Jones
Travis Jones
BFBrendan T Fuller
Brendan T Fuller
.T. Joseph W. Tinapple
. Joseph W. Tinapple
JSJonathan W. Song
Jonathan W. Song
Continuous perfusion is necessary to sustain microphysiological systems and other microfluidic cell cultures. However, most of the established microfluidic perfusion systems, such as syringe pumps, peristaltic pumps, and rocker plates, have several operational challenges and may be cost-prohibitive, especially for laboratories with no microsystems engineering expertise. Here, we address the need for a cost-efficient, easy-to-implement, and reliable microfluidic perfusion system. Our solution is a modular pumpless perfusion assembly (PPA), which is constructed from commercially available, interchangeable, and aseptically packaged syringes and syringe filters. The total cost for the components of each assembled PPA is USD 1–2. The PPA retains the simplicity of gravity-based pumpless flow systems but incorporates high resistance filters that enable slow and sustained flow for extended periods of time (hours to days). The perfusion characteristics of the PPA were determined by theoretical calculations of the total hydraulic resistance of the assembly and experimental characterization of specific filter resistances. We demonstrated that the PPA enabled reliable long-term culture of engineered endothelialized 3-D microvessels for several weeks. Taken together, our novel PPA solution is simply constructed from extremely low-cost and commercially available laboratory supplies and facilitates robust cell culture and compatibility with current microfluidic setups.

7 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SAShashwat Agarwal
Shashwat Agarwal
JHJacob Cozean Holter
Jacob Cozean Holter
TJTravis Jones
Travis Jones
BFBrendan T Fuller
Brendan T Fuller
.T. Joseph W. Tinapple
. Joseph W. Tinapple
JSJonathan W. Song
Jonathan W. Song
Continuous perfusion is necessary to sustain microphysiological systems and other microfluidic cell cultures. However, most of the established microfluidic perfusion systems, such as syringe pumps, peristaltic pumps, and rocker plates, have several operational challenges and may be cost-prohibitive, especially for laboratories with no microsystems engineering expertise. Here, we address the need for a cost-efficient, easy-to-implement, and reliable microfluidic perfusion system. Our solution is a modular pumpless perfusion assembly (PPA), which is constructed from commercially available, interchangeable, and aseptically packaged syringes and syringe filters. The total cost for the components of each assembled PPA is $1-2 USD. The PPA retains the simplicity of gravity-based pumpless flow systems but incorporates high resistance filters that enable slow and sustained flow for extended periods of time (hours to days). The perfusion characteristics of the PPA were determined by theoretical calculations of the total hydraulic resistance of the assembly and experimental characterization of specific filter resistances. We demonstrated that the PPA enabled reliable long-term culture of engineered endothelialized 3-D microvessels for several weeks. Taken together, our novel PPA solution is simply constructed from extremely low cost and commercially available laboratory supplies and facilitates robust cell culture and compatibility with current microfluidic setups.

3 July 2024 in ChemRxiv
Verified
Preprint
Open access
PDF file
JSJonathan W. Song
Jonathan W. Song
SAShashwat Agarwal
Shashwat Agarwal
MCMarcos Cortes-Medina
Marcos Cortes-Medina
JHJacob Cozean Holter
Jacob Cozean Holter
AAAlex Avendano
Alex Avendano
LOLotanna M. Onua
Lotanna M. Onua
Blood and lymphatic vessels in the body are central to molecular and cellular transport, tissue repair, and pathophysiology. Several approaches have been employed for engineering microfabricated blood and lymphatic vessels in vitro, yet these approaches invariably require specialized equipment, facilities, and research training beyond the capabilities of most biomedical laboratories. Here we present xurography as an inexpensive, accessible, and versatile rapid prototyping technique for engineering cylindrical and lumenized microvessels. Using a benchtop xurographer, or a cutting plotter, we fabricated modular multi-layer poly(dimethysiloxane) (PDMS) -based microphysiological systems (MPS) that house endothelial-lined microvessels approximately 260μm in diameter embedded within a user-defined 3-D extracellular matrix (ECM). We validated the vascularized MPS (or vessel-on-a-chip) by quantifying changes in blood vessel permeability due to the pro-angiogenic chemokine CXCL12. Moreover, we demonstrated the reconfigurable versatility of this approach by engineering three different vessel-ECM arrangements, which were obtained by minor adjustments to one or two steps of the fabrication process. Several of these arrangements, such as ones that incorporate close-ended vessel structures and spatially distinct ECM compartments along the same microvessel, cannot be readily achieved with other microfabrication strategies. Therefore, we anticipate that our low-cost and easy-to-implement fabrication approach will facilitate wider accessibility of MPS with tunable vascular architectures and ECM components while reducing the turnaround time required for iterative designs.