Travis Jones

Dr. Travis Jones

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2019 in Communications Biology
Verified
Journal Article
Open access
PDF file
AGAyush Arpit Garg
Ayush Arpit Garg
TJTravis Jones
Travis Jones
SMSarah M. Moss
Sarah M. Moss
SMSanjay Mishra
Sanjay Mishra
KKKirti Kaul
Kirti Kaul
JSJonathan W. Song
Jonathan W. Song
Interactions between cells and their environment influence key physiologic processes such as their propensity to migrate. However, directed migration controlled by extrinsically applied electrical signals is poorly understood. Using a novel microfluidic platform, we found that metastatic breast cancer cells sense and respond to the net direction of weak (∼100 µV cm−1), asymmetric, non-contact induced Electric Fields (iEFs). iEFs inhibited EGFR (Epidermal Growth Factor Receptor) activation, prevented formation of actin-rich filopodia, and hindered the motility of EGF-treated breast cancer cells. The directional effects of iEFs were nullified by inhibition of Akt phosphorylation. Moreover, iEFs in combination with Akt inhibitor reduced EGF-promoted motility below the level of untreated controls. These results represent a step towards isolating the coupling mechanism between cell motility and iEFs, provide valuable insights into how iEFs target multiple diverging cancer cell signaling mechanisms, and demonstrate that electrical signals are a fundamental regulator of cancer cell migration.

9 June 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DADinesh K. Ahirwar
Dinesh K. Ahirwar
Mohd NasserMohd Nasser
Mohd Nasser
TJTravis Jones
Travis Jones
ESEmily K. Sequin
Emily K. Sequin
JWJoseph D. West
Joseph D. West
VSVish Subramaniam
Vish Subramaniam
We present a method to induce electric fields and drive electrotaxis (galvanotaxis) without the need for electrodes to be in contact with the media containing the cell cultures. We report experimental results using a modification of the transmembrane assay, demonstrating the hindrance of migration of breast cancer cells (SCP2) when an induced a.c. electric field is present in the appropriate direction (i.e. in the direction of migration). Of significance is that migration of these cells is hindered at electric field strengths many orders of magnitude (5 to 6) below those previously reported for d.c. electrotaxis and even in the presence of a chemokine (SDF-1α) or a growth factor (EGF). Induced a.c. electric fields applied in the direction of migration are also shown to hinder motility of non-transformed human mammary epithelial cells (MCF10A) in the presence of the growth factor EGF. In addition, we also show how our method can be applied to other cell migration assays (scratch assay) and by changing the coil design and holder, that it is also compatible with commercially available multi-well culture plates.

19 March 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
SAShashwat Agarwal
Shashwat Agarwal
JHJacob Cozean Holter
Jacob Cozean Holter
TJTravis Jones
Travis Jones
BFBrendan T Fuller
Brendan T Fuller
.T. Joseph W. Tinapple
. Joseph W. Tinapple
JSJonathan W. Song
Jonathan W. Song
Continuous perfusion is necessary to sustain microphysiological systems and other microfluidic cell cultures. However, most of the established microfluidic perfusion systems, such as syringe pumps, peristaltic pumps, and rocker plates, have several operational challenges and may be cost-prohibitive, especially for laboratories with no microsystems engineering expertise. Here, we address the need for a cost-efficient, easy-to-implement, and reliable microfluidic perfusion system. Our solution is a modular pumpless perfusion assembly (PPA), which is constructed from commercially available, interchangeable, and aseptically packaged syringes and syringe filters. The total cost for the components of each assembled PPA is USD 1–2. The PPA retains the simplicity of gravity-based pumpless flow systems but incorporates high resistance filters that enable slow and sustained flow for extended periods of time (hours to days). The perfusion characteristics of the PPA were determined by theoretical calculations of the total hydraulic resistance of the assembly and experimental characterization of specific filter resistances. We demonstrated that the PPA enabled reliable long-term culture of engineered endothelialized 3-D microvessels for several weeks. Taken together, our novel PPA solution is simply constructed from extremely low-cost and commercially available laboratory supplies and facilitates robust cell culture and compatibility with current microfluidic setups.

7 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SAShashwat Agarwal
Shashwat Agarwal
JHJacob Cozean Holter
Jacob Cozean Holter
TJTravis Jones
Travis Jones
BFBrendan T Fuller
Brendan T Fuller
.T. Joseph W. Tinapple
. Joseph W. Tinapple
JSJonathan W. Song
Jonathan W. Song
Continuous perfusion is necessary to sustain microphysiological systems and other microfluidic cell cultures. However, most of the established microfluidic perfusion systems, such as syringe pumps, peristaltic pumps, and rocker plates, have several operational challenges and may be cost-prohibitive, especially for laboratories with no microsystems engineering expertise. Here, we address the need for a cost-efficient, easy-to-implement, and reliable microfluidic perfusion system. Our solution is a modular pumpless perfusion assembly (PPA), which is constructed from commercially available, interchangeable, and aseptically packaged syringes and syringe filters. The total cost for the components of each assembled PPA is $1-2 USD. The PPA retains the simplicity of gravity-based pumpless flow systems but incorporates high resistance filters that enable slow and sustained flow for extended periods of time (hours to days). The perfusion characteristics of the PPA were determined by theoretical calculations of the total hydraulic resistance of the assembly and experimental characterization of specific filter resistances. We demonstrated that the PPA enabled reliable long-term culture of engineered endothelialized 3-D microvessels for several weeks. Taken together, our novel PPA solution is simply constructed from extremely low cost and commercially available laboratory supplies and facilitates robust cell culture and compatibility with current microfluidic setups.

1 August 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
TJTravis Jones
Travis Jones
JJJ. Javor
J. Javor
ESE. K. Sequin
E. K. Sequin
JWJ. D. West
J. D. West
SPShaurya Prakash
Shaurya Prakash
VSV. V. Subramaniam
V. V. Subramaniam
We present a method for designing and optimizing an in-house designed electromagnetic probe for distinguishing morphological differences in biological tissues. The probe comprises concentric multi-wound coils, the inner being the primary coil and the outer being the detector coil. A time-varying voltage is imposed on the primary coil, resulting in an induced current in the detector coil. For highly conductive samples, eddy currents are induced in the sample and inductively couple with the electromagnetic probe. However, in weakly conducting samples, the primary coupling mechanism is found to be capacitive though there can be a non-negligible inductive component. Both the mutual inductive coupling and the capacitive coupling between the sample and the probe are detected as a change in the induced voltage of the detector coil using lock-in detection. The induced voltage in the detector coil is influenced more by the morphological structure of the specimen rather than by changes in electrical conductivity within different regions of the sample. The instrument response of the lock-in amplifier is also examined with simulated input voltage signals to relate its output to specific changes in inductive and capacitive coupling, in order to relate sample characteristics to a single voltage output. A circuit element model is used to interpret the experimental measurements. It is found that the sensitivity of the measurement for a given set of probe characteristics (resistances, inductances, and capacitances) can be optimized by adding a small amount of capacitance in the external circuit in parallel with the detector coil. Illustrative measurements are presented on animal (porcine and bovine) tissue and on human liver tissue containing a metastatic tumor to demonstrate the capabilities of the probe and measurement method in distinguishing different tissue types despite having similar electrical conductivities. Since biological tissues are multi-scale, heterogeneous materials comprising regions of differing conductivity, permittivity, and morphological structure, the electromagnetic method presented here has the potential to examine structural variations in tissue undergoing physical changes due to healing or disease.

23 October 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
ECEmily T. Chan
Emily T. Chan
TJTravis Jones
Travis Jones
CTCristopher M. Thompson
Cristopher M. Thompson
HKHariharan Kannan
Hariharan Kannan
MDMalcolm D'Souza
Malcolm D'Souza
JSJonathan W. Song
Jonathan W. Song
Cell migration through confined spaces is a critical step in cancer metastasis, yet the spatial regulation of endocytosis and adhesion dynamics during this process remains poorly understood. To investigate this, we adapted a microfluidic platform that generates stable, spatially linear biochemical gradients across 5 μm-tall migration channels. COMSOL simulations and optical calibration using FITC-dextran confirmed that gradients form reliably within 5 min. The microdevice also supports long-term live imaging and is compatible with both spinning disk confocal and total internal reflection fluorescence structured illumination microscopy modalities, enabling high-resolution visualization of adhesion and endocytic structures. By leveraging this platform for spatially restricted drug delivery, we locally applied the endocytic inhibitor Dyngo-4a to either the front or rear of migrating cells. This revealed that front-targeted endocytic inhibition preserved or increased leading-edge enrichment of paxillin and the clathrin adaptor AP-2, whereas rear-targeted inhibition eliminated paxillin polarity and reduced AP-2 polarity. These changes were accompanied by a significant increase in cell migration speed under front-targeted inhibition, while rear-targeted inhibition had no significant effect on speed and neither treatment altered persistence. Together, these findings suggest that endocytic polarity regulates adhesion dynamics and cell migration under confinement, offering a mechanistic insight into processes relevant to cancer cell invasion.