Climatic hazards, such as hurricanes and ice-storms, pose a top threat to power distribution systems. This paper proposes a resilience-enhancing strategy to make distribution systems more resilient to climatic hazards. The proposed strategy consists of three resilience-oriented design (ROD) measures, namely line hardening, installing backup distributed generators (DGs), and adding automatic switches. The main challenges of this problem are i) modeling the spatio-temporal correlation among ROD decisions and uncertainties, ii) capturing the entire failure-recovery-cost process, and iii) solving the resultant largescale mixed-integer stochastic problem efficiently. To deal with these challenges, we propose a hybrid stochastic process with deterministic casual structure to model the spatio-temporal correlations of uncertainties. A new two-stage stochastic mixed-integer linear program (MILP) is formulated to capture the impacts of ROD decisions and uncertainties on system's responses to climatic hazards. The objective is to minimize the ROD investment cost in the first stage and the expected costs of loss of load, DG operation, and damage repairs in the second stage. A dual decomposition (DD) algorithm with branch-and-bound is developed to solve the proposed model with binary variables in both stages. Case studies on the IEEE 123-bus test feeder show the proposed approach can improve the system resilience at minimum costs.
Transient stability boundary is an important tool for the security and stability analysis of power systems, but typically, obtaining it will result in a high computational burden. Existing methods for obtaining transient stability boundary often involve grid scanning, which generates a large number of dense operating points, followed by transient simulation, which incurs substantial time costs. This paper proposes a method for transient stability boundary exploration based on a Support Vector Machine (SVM), which uses a small number of operating points to obtain a more precise stability boundary while efficiently and accurately acquiring stable operating points near the stability boundary. Firstly, the SVM is employed to classify the initial samples and determine the transient stability boundary under the N-1 fault. Secondly, re-sampling is conducted for operating points near the stability boundary determined by the initial samples. After updating the sample set, SVM classification is performed again. This process is iterated multiple times, and the operating points are continuously generated in the direction oriented toward the actual stability boundary while obtaining a more precise transient stability boundary under the N-1 fault. Finally, the proposed method is validated using actual operational data from a regional power grid of China Southern Power Grid (Guangzhou, China), demonstrating the accuracy and efficiency of the proposed approach.
Online power-system defense increasingly depends on automated assessment, strategy generation, and real-time implementation. However, the accuracy of a single model or controller does not establish the trustworthiness of the complete closed loop. This paper proposes a mission-level framework for closed-loop trustworthiness under physical, informational, and temporal uncertainty. Trustworthiness is defined as the lowest finite-horizon mission-success probability over all probability laws consistent with available evidence. The resulting trustworthiness viability domain contains the joint physical, evidence, dependence, and response-time states from which a required trustworthiness level remains achievable. A recursive characterization supports model-conditional certification and boundary warning. Additional evidence can reduce maintainable trustworthiness when its acquisition delay removes feasible recovery actions. Safe abnormality identifiability requires diagnostic actions to remain inside the viability domain, while a counterfactual deficit measure locates abnormalities with the largest mission-level effect. Conditions are also derived for heterogeneous redundancy and certified fallback. On a modified Reliability Test System–Grid Modernization Lab Consortium (RTS-GMLC) system, 14.3% of test states were physically secure but were not certified at the required trustworthiness level. Under the scenario-based model, 94.6% of abnormal cases met the 0.95 trustworthiness threshold with runtime selection. Texas2k tests quantified the accuracy–runtime tradeoff at a larger network scale.