Jianxin Zhang

Mr. Jianxin Zhang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
GXGuanghu Xu
Guanghu Xu
JQJian Qiu
Jian Qiu
JZJianxin Zhang
Jianxin Zhang
HYHuanhuan Yang
Huanhuan Yang
QGQin Gao
Qin Gao
YWYuan Wang
Yuan Wang
The large-scale integration of wind power significantly alters the voltage dynamic characteristics of power systems. Wind turbines have a weak ability to withstand grid disturbances and have difficulty in providing effective reactive power support during transient periods. The sensitivity of wind turbines to the grid voltage significantly increases the probability of large-scale, cascading off-grid events. This paper proposes a coordinated control strategy to enhance the transient reactive power support capability of doubly fed wind farms. The additional stator current demagnetization control reduces the risk of a crowbar protection action after a fault and ensures that the unit power is controllable. Based on the voltage–reactive power coupling relationship, each unit can produce reactive power according to the voltage–reactive power sensitivity matrix during the transient period. After the reactive power output of the unit reaches the limit, transient active and reactive combined control is further adopted to reduce the active power output of the unit to a certain extent and improve the reactive power support capability. Finally, two cases are built in the PSCAD to verify the effectiveness of the proposed control strategy. The results show that the proposed control strategy can enable the wind farm to output more reactive power to the grid during the transient period, effectively supporting the system voltage during the transient process and avoiding further deterioration of the fault.

21 July 2026 in Energies
Verified
Journal Article
Open access
PDF file
JZJianxin Zhang
Jianxin Zhang
HYHuanhuan Yang
Huanhuan Yang
HHHe Huang
He Huang
TJTuo Jiang
Tuo Jiang
HZHongxuan Zhang
Hongxuan Zhang
Siyang LiaoSiyang Liao
Siyang Liao
To address the low accuracy and poor reliability of short-term photovoltaic (PV) power forecasting under complex weather conditions, this study proposes a multi-strategy synergistic optimization framework for point-interval prediction. The methodology integrates similar day classification (SDC) via RDP-DTW-DBA-K-means, a hybrid BiTCN-MAOBiGRU-AM model with a mutation-aware mechanism, and Dream Optimization Algorithm (DOA) for global hyperparameter tuning of six key parameters. For interval prediction, an adaptive bandwidth kernel density estimation (ABKDE) dynamically adjusts bandwidth based on local error density and weather scenarios. Experiments using data from a Guangxi PV station demonstrate that the synergistic model reduces RMSE by 29.58% (cloudy) and 32.37% (overcast/rainy) versus the baseline, and cuts RMSE by 16.2–19.0% under abrupt weather events and 22.4–40.2% under non-ideal input data. At the 95% confidence level, ABKDE improves prediction interval coverage probability by 3.9–5.4 percentage points and reduces normalized average width by 20.8–23.6% compared to conventional KDE. The proposed framework significantly enhances prediction accuracy, robustness, and generalization, offering a reliable solution for PV power forecasting in highly variable meteorological scenarios.

8 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
HYHuanhuan Yang
Huanhuan Yang
HHHe Huang
He Huang
JZJianxin Zhang
Jianxin Zhang
TJTuo Jiang
Tuo Jiang
HZHongxuan Zhang
Hongxuan Zhang
ZZZhe Zhang
Zhe Zhang
The high penetration of renewable energy has posed significant challenges to frequency regulation, primarily due to the scarcity of traditional regulation resources in these regions. To address this, a novel secondary frequency regulation control method utilizing voltage-sensitive flexible load (VSFL) clusters is proposed. The strategy leverages the voltage-active power coupling characteristics of composite loads. By regulating the load voltage, composite loads under 110/10 kV substations are transformed into controllable loads, which are then aggregated to collaborate with Automatic Generation Control (AGC) units in SFR. To tackle the inherent uncertainty in load regulation capacity, a load control signal correction strategy based on Tube-based Model Predictive Control (T-MPC) is designed. This strategy effectively compensates for calculation errors in control objectives caused by load uncertainty, achieving optimal control with minimal cost. Simulation results demonstrate that the proposed scheme enables the large-scale mining and flexible utilization of load-side regulation resources. Furthermore, the T-MPC approach exhibits superior robustness and frequency regulation performance compared to traditional MPC methods.

4 November 2026 in Modelling
Verified
Journal Article
Open access
PDF file
WTWei Tai
Wei Tai
JCJinchang Chen
Jinchang Chen
JZJianxin Zhang
Jianxin Zhang
SLShiyang Li
Shiyang Li
QWQi Wang
Qi Wang
LTLian Tu
Lian Tu
Online power-system defense increasingly depends on automated assessment, strategy generation, and real-time implementation. However, the accuracy of a single model or controller does not establish the trustworthiness of the complete closed loop. This paper proposes a mission-level framework for closed-loop trustworthiness under physical, informational, and temporal uncertainty. Trustworthiness is defined as the lowest finite-horizon mission-success probability over all probability laws consistent with available evidence. The resulting trustworthiness viability domain contains the joint physical, evidence, dependence, and response-time states from which a required trustworthiness level remains achievable. A recursive characterization supports model-conditional certification and boundary warning. Additional evidence can reduce maintainable trustworthiness when its acquisition delay removes feasible recovery actions. Safe abnormality identifiability requires diagnostic actions to remain inside the viability domain, while a counterfactual deficit measure locates abnormalities with the largest mission-level effect. Conditions are also derived for heterogeneous redundancy and certified fallback. On a modified Reliability Test System–Grid Modernization Lab Consortium (RTS-GMLC) system, 14.3% of test states were physically secure but were not certified at the required trustworthiness level. Under the scenario-based model, 94.6% of abnormal cases met the 0.95 trustworthiness threshold with runtime selection. Texas2k tests quantified the accuracy–runtime tradeoff at a larger network scale.

6 January 2026
Verified
Book Chapter
Closed access
PDF file
JZJianxin Zhang
Jianxin Zhang
QGQin Gao
Qin Gao
KLKexin Li
Kexin Li
JAJun An
Jun An
HYHuanhuan Yang
Huanhuan Yang
YZYibo Zhou
Yibo Zhou

14 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
JZJianxin Zhang
Jianxin Zhang
HYHuanhuan Yang
Huanhuan Yang
HHHe Huang
He Huang
TJTuo Jiang
Tuo Jiang
HZHongxuan Zhang
Hongxuan Zhang
Siyang LiaoSiyang Liao
Siyang Liao
A total of three revisions are needed to the original manuscript