Paulo Rocha

Dr. Paulo Rocha

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2016 in Scientific Reports
Verified
Journal Article
Open access
Paulo RochaPaulo Rocha
Paulo Rocha
PSPaul Schlett
Paul Schlett
UKUlrike Kintzel
Ulrike Kintzel
VMVolker Mailänder
Volker Mailänder
LVLode K. J. Vandamme
Lode K. J. Vandamme
DLDago M. de Leeuw
Dago M. de Leeuw
Microelectrode arrays (MEA) record extracellular local field potentials of cells adhered to the electrodes. A disadvantage is the limited signal-to-noise ratio. The state-of-the-art background noise level is about 10 μVpp. Furthermore, in MEAs low frequency events are filtered out. Here, we quantitatively analyze Au electrode/electrolyte interfaces with impedance spectroscopy and noise measurements. The equivalent circuit is the charge transfer resistance in parallel with a constant phase element that describes the double layer capacitance, in series with a spreading resistance. This equivalent circuit leads to a Maxwell-Wagner relaxation frequency, the value of which is determined as a function of electrode area and molarity of an aqueous KCl electrolyte solution. The electrochemical voltage and current noise is measured as a function of electrode area and frequency and follow unambiguously from the measured impedance. By using large area electrodes the noise floor can be as low as 0.3 μVpp. The resulting high sensitivity is demonstrated by the extracellular detection of C6 glioma cell populations. Their minute electrical activity can be clearly detected at a frequency below about 10 Hz, which shows that the methodology can be used to monitor slow cooperative biological signals in cell populations.

20 May 2020 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
ZSZoe Schofield
Zoe Schofield
GMGabriel N. Meloni
Gabriel N. Meloni
PTPeter Tran
Peter Tran
CZChristian Zerfass
Christian Zerfass
GSGiovanni Sena
Giovanni Sena
OSOrkun S. Soyer
Orkun S. Soyer
The last five decades of molecular and systems biology research have provided unprecedented insights into the molecular and genetic basis of many cellular processes. Despite these insights, however, it is arguable that there is still only limited predictive understanding of cell behaviours. In particular, the basis of heterogeneity in single-cell behaviour and the initiation of many different metabolic, transcriptional or mechanical responses to environmental stimuli remain largely unexplained. To go beyond thestatus quo, the understanding of cell behaviours emerging from molecular genetics must be complemented with physical and physiological ones, focusing on the intracellular and extracellular conditions within and around cells. Here, we argue that such a combination of genetics, physics and physiology can be grounded on a bioelectrical conceptualization of cells. We motivate the reasoning behind such a proposal and describe examples where a bioelectrical view has been shown to, or can, provide predictive biological understanding. In addition, we discuss how this view opens up novel ways to control cell behaviours by electrical and electrochemical means, setting the stage for the emergence of bioelectrical engineering.

30 April 2020 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
MRMafalda Ribeiro
Mafalda Ribeiro
AEAya Elghajiji
Aya Elghajiji
SFScott P. Fraser
Scott P. Fraser
ZBZoë D. Burke
Zoë D. Burke
DTDavid Tosh
David Tosh
Paulo RochaPaulo Rocha
Paulo Rocha
Breast cancer is one of the most prevalent types of cancers worldwide and yet, its pathophysiology is poorly understood. Single-cell electrophysiological studies have provided evidence that membrane depolarization is implicated in the proliferation and metastasis of breast cancer. However, metastatic breast cancer cells are highly dynamic microscopic systems with complexities beyond a single-cell level. There is an urgent need for electrophysiological studies and technologies capable of decoding the intercellular signaling pathways and networks that control proliferation and metastasis, particularly at a population level. Hence, we present for the first time non-invasive in vitro electrical recordings of strongly metastatic MDA-MB-231 and weakly/non-metastatic MCF-7 breast cancer cell lines. To accomplish this, we fabricated an ultra-low noise sensor that exploits large-area electrodes, of 2 mm2, which maximizes the double-layer capacitance and concomitant detection sensitivity. We show that the current recorded after adherence of the cells is dominated by the opening of voltage-gated sodium channels (VGSCs), confirmed by application of the highly specific inhibitor, tetrodotoxin (TTX). The electrical activity of MDA-MB-231 cells surpasses that of the MCF-7 cells, suggesting a link between the cells’ bioelectricity and invasiveness. We also recorded an activity pattern with characteristics similar to that of Random Telegraph Signal (RTS) noise. RTS patterns were less frequent than the asynchronous VGSC signals. The RTS noise power spectral density showed a Lorentzian shape, which revealed the presence of a low-frequency signal across MDA-MB-231 cell populations with propagation speeds of the same order as those reported for intercellular Ca2+ waves. Our recording platform paves the way for real-time investigations of the bioelectricity of cancer cells, their ionic/pharmacological properties and relationship to metastatic potential.

3 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MCMiguel Cabello
Miguel Cabello
HGHaobo Ge
Haobo Ge
CACarmen Aracil
Carmen Aracil
DMDespina Moschou
Despina Moschou
Pedro EstrelaPedro Estrela
Pedro Estrela
Paulo RochaPaulo Rocha
Paulo Rocha
Although prostate cancer is one of the most common cancers in the male population, its basic biological function at a cellular level remains to be fully understood. This lack of in depth understanding of its physiology significantly hinders the development of new, targeted and more effective treatment strategies. Whilst electrophysiological studies can provide in depth analysis, the possibility of recording electrical activity in large populations of non-neuronal cells remains a significant challenge, even harder to address in the picoAmpere-range, which is typical of cellular level electrical activities. In this paper, we present the measurement and characterization of electrical activity of populations of prostate cancer cells PC-3, demonstrating for the first time a meaningful electrical pattern. The low noise system used comprises a multi-electrode array (MEA) with circular gold electrodes on silicon oxide substrates. The extracellular capacitive currents present two standard patterns: an asynchronous sporadic pattern and a synchronous quasi-periodic biphasic spike pattern. An amplitude of ±150 pA, a width between 50–300 ms and an inter-spike interval around 0.5 Hz characterize the quasi-periodic spikes. Our experiments using treatment of cells with Gd3⁺, known as an inhibitor for the Ca2⁺ exchanges, suggest that the quasi-periodic signals originate from Ca2⁺ channels. After adding the Gd3⁺ to a population of living PC-3 cells, their electrical activity considerably decreased; once the culture was washed, thus eliminating the Gd3⁺ containing medium and addition of fresh cellular growth medium, the PC-3 cells recovered their normal electrical activity. Cellular viability plots have been carried out, demonstrating that the PC-3 cells remain viable after the use of Gd3⁺, on the timescale of this experiment. Hence, this experimental work suggests that Ca2⁺ is significantly affecting the electrophysiological communication pattern among PC-3 cell populations. Our measuring platform opens up new avenues for real time and highly sensitive investigations of prostate cancer signalling pathways.

2 December 2016 in Science Advances
Verified
Journal Article
Open access
PDF file
Paulo RochaPaulo Rocha
Paulo Rocha
MMMaria Medeiros
Maria Medeiros
UKUlrike Kintzel
Ulrike Kintzel
JVJohannes Vogt
Johannes Vogt
Inês AraújoInês Araújo
Inês Araújo
Henrique Leonel GomesHenrique Leonel Gomes
Henrique Leonel Gomes
Glioma patients often suffer from epileptic seizures because of the tumor’s impact on the brain physiology. Using the rat glioma cell line C6 as a model system, we performed long-term live recordings of the electrical activity of glioma populations in an ultrasensitive detection method. The transducer exploits large-area electrodes that maximize double-layer capacitance, thus increasing the sensitivity. This strategy allowed us to record glioma electrical activity. We show that although glioma cells are nonelectrogenic, they display a remarkable electrical burst activity in time. The low-frequency current noise after cell adhesion is dominated by the flow of Na+ ions through voltage-gated ion channels. However, after an incubation period of many hours, the current noise markedly increased. This electric bursting phenomenon was not associated with apoptosis because the cells were viable and proliferative during the period of increased electric activity. We detected a rapid cell culture medium acidification accompanying this event. By using specific inhibitors, we showed that the electrical bursting activity was prompted by extracellular pH changes, which enhanced Na+ ion flux through the psalmotoxin 1–sensitive acid-sensing ion channels. Our model of pH-triggered bursting was unambiguously supported by deliberate, external acidification of the cell culture medium. This unexpected, acidosis-driven electrical activity is likely to directly perturb, in vivo, the functionality of the healthy neuronal network in the vicinity of the tumor bulk and may contribute to seizures in glioma patients.

1 September 2016 in Sensing and Bio-Sensing Research
Verified
Journal Article
Open access
MMMaria Medeiros
Maria Medeiros
AMAna Mestre
Ana Mestre
PEDRO INÁCIOPEDRO INÁCIO
PEDRO INÁCIO
SASanaz Asgarif
Sanaz Asgarif
Inês AraújoInês Araújo
Inês Araújo
Henrique Leonel GomesHenrique Leonel Gomes
Henrique Leonel Gomes
An electrical method to measure extracellular bioelectrical activity in vitro is presented. This method exploits the Helmholtz capacitive double-layer established at the electrode surface. Small extracellular voltage variations in the order of μVs induce through the double-layer capacitor a displacement current that is measured. This current is then enhanced by a gain factor proportional to the electrode capacitance. In addition, when measurements are carried out at low frequencies in current mode the electrode contribution to the noise can be minimized. The performance of the electrodes and the method is demonstrated using zebrafish hearts and glioma cell cultures. We propose that this electrical method is an ideal tool to measure in vitro slow and temporally synchronized events that are often involved in long range intracellular signaling