Jiho Nam

Jiho Nam

Auto-generated profile, based on publicly available information

Jiho Nam

Department of Radiation Oncology, Pusan National University Hospital, Busan, Korea

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
YKYongkan Ki
Yongkan Ki
WKWontaek Kim
Wontaek Kim
YKYong Ho Kim
Yong Ho Kim
DKDonghyun Kim
Donghyun Kim
JBJin Sook Bae
Jin Sook Bae
JNJiho Nam
Jiho Nam
Ki Y, et al. J Korean Med Sci. 2017 May;32(5):757-763. https://doi.org/10.3346/jkms.2017.32.5.757

28 July 2015 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
HJHosang Jeon
Hosang Jeon
MCMyung Jin Chung
Myung Jin Chung
SYSeungman Youn
Seungman Youn
JNJiho Nam
Jiho Nam
JLJayoung Lee
Jayoung Lee
HKHo Kyung Kim
Ho Kyung Kim
One of the emerging issues in radiography is low-dose imaging to minimize patient’s exposure. The scintillating materials employed in most indirect flat-panel detectors show a drastic change of X-ray photon absorption efficiency around their K-edge energies that consequently affects image quality. Using various tube voltages, we investigated the imaging performance of most popular scintillators: cesium iodide (CsI) and gadolinium oxysulfide (Gd2O2S). The integrated detective quantum efficiencies (iDQE) of four detectors installed in the same hospital were evaluated according to the standardized procedure IEC 62220-1 at tube voltages of 40 - 120 kVp. The iDQE values of the Gd2O2S detectors were normalized by those of CsI detectors to exclude the effects of image postprocessing. The contrast-to-noise ratios (CNR) were also evaluated by using an anthropomorphic chest phantom. The iDQE of the CsI detector outperformed that of the Gd2O2S detector over all tube voltages. Moreover, we noted that the iDQE of the Gd2O2S detectors quickly rolled off with decreasing tube voltage under 70 kVp. The CNRs of the two scintillators were similar at 120 kVp. At 60 kVp, however, the CNR of Gd2O2S was about half that of CsI. Compared to the Gd2O2S detectors, variations in the DQE performance of the CsI detectors were relatively immune to variations in the applied tube voltages. Therefore, we claim that Gd2O2S detectors are inappropriate for use in low-tube-voltage imaging (e.g., extremities and pediatrics) with low patient exposure.

12 June 2023 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
HJHosang Jeon
Hosang Jeon
JJJi Hyeon Joo
Ji Hyeon Joo
YKYongkan Ki
Yongkan Ki
WKWontaek Kim
Wontaek Kim
DPDahl Park
Dahl Park
DKDonghyun Kim
Donghyun Kim

31 December 2022 in Progress in Medical Physics
Verified
Journal Article
Open access
PDF file
HLHojeong Lee
Hojeong Lee
JJJi Hyeon Joo
Ji Hyeon Joo
YKYongkan Ki
Yongkan Ki
WKWontaek Kim
Wontaek Kim
DPDahl Park
Dahl Park
HJHosang Jeon
Hosang Jeon
Hojeong Lee, Dong Woon Kim, Ji Hyeon Joo, Yongkan Ki, Wontaek Kim , Dahl Park, Jiho Nam, Dong Hyeon Kim, Hosang Jeon. Progress in Medical Physics 2022;33:101-7. https://doi.org/10.14316/pmp.2022.33.4.101

2 June 2022 in Asia-Pacific Journal of Clinical Oncology
Verified
Journal Article
Closed access
HJHosang Jeon
Hosang Jeon
YKYongkan Ki
Yongkan Ki
DKDong Woon Kim
Dong Woon Kim
WKWontaek Kim
Wontaek Kim
JNJiho Nam
Jiho Nam
JJJi Hyeon Joo
Ji Hyeon Joo

30 June 2024 in Progress in Medical Physics
Verified
Journal Article
Open access
PDF file
HLHojeong Lee
Hojeong Lee
JJJi Hyeon Joo
Ji Hyeon Joo
YKYongkan Ki
Yongkan Ki
WKWontaek Kim
Wontaek Kim
DPDahl Park
Dahl Park
HJHosang Jeon
Hosang Jeon
Hojeong Lee, Dong Woon Kim, Ji Hyeon Joo, Yongkan Ki, Wontaek Kim, Dahl Park, Jiho Nam, Dong Hyeon Kim, Hosang Jeon. Progress in Medical Physics 2024;35:52-7. https://doi.org/10.14316/pmp.2024.35.2.52