Jordan Vincent

Mr. Jordan Vincent

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JVJordan Vincent
Jordan Vincent
HWHui Wang
Hui Wang
ONOmar Nibouche
Omar Nibouche
PMPAUL MAGUIRE
PAUL MAGUIRE
Food fraud, the sale of goods that have in some way been mislabelled or tampered with, is an increasing concern, with a number of high profile documented incidents in recent years. These recent incidents and their scope show that there are gaps in the food chain where food authentication methods are not applied or otherwise not sufficient and more accessible detection methods would be beneficial. This paper investigates the utility of affordable and portable visible range spectroscopy hardware with partial least squares discriminant analysis (PLS-DA) when applied to the differentiation of apple types and organic status. This method has the advantage that it is accessible throughout the supply chain, including at the consumer level. Scans were acquired of 132 apples of three types, half of which are organic and the remaining non-organic. The scans were preprocessed with zero correction, normalisation and smoothing. Two tests were used to determine accuracy, the first using 10-fold cross-validation and the second using a test set collected in different ambient conditions. Overall, the system achieved an accuracy of 94% when predicting the type of apple and 66% when predicting the organic status. Additionally, the resulting models were analysed to find the regions of the spectrum that had the most significance. Then, the accuracy when using three-channel information (RGB) is presented and shows the improvement provided by spectroscopic data.

1 August 2020 in Plasma Sources Science and Technology
Verified
Journal Article
Open access
JVJordan Vincent
Jordan Vincent
HWHui Wang
Hui Wang
ONOmar Nibouche
Omar Nibouche
PMPAUL MAGUIRE
PAUL MAGUIRE
Trace methane detection in the parts per million range is reported using a novel detection scheme based on optical emission spectra from low temperature atmospheric pressure microplasmas. These bright low-cost plasma sources were operated under non-equilibrium conditions, producing spectra with a complex and variable sensitivity to trace levels of added gases. A data-driven machine learning approach based on partial least squares discriminant analysis was implemented for CH4 concentrations up to 100 ppm in He, to provide binary classification of samples above or below a threshold of 2 ppm. With a low-resolution spectrometer and a custom spectral alignment procedure, a prediction accuracy of 98% was achieved, demonstrating the power of machine learning with otherwise prohibitively complex spectral analysis. This work establishes proof of principle for low cost and high-resolution trace gas detection with the potential for field deployment and autonomous remote monitoring.

8 November 2025 in Intelligent Systems with Applications
Verified
Journal Article
Open access
BLBronagh Lanigan
Bronagh Lanigan
ZRZeinab Rezaeifar
Zeinab Rezaeifar
FCFederico Cruciani
Federico Cruciani
MMMichael Milliken
Michael Milliken
JVJordan Vincent
Jordan Vincent
AHAlex Healing
Alex Healing

8 October 2019
Verified
Conference Paper
Open access
HWHui Wang
Hui Wang
WSWeiran Song
Weiran Song
NJNanfeng Jiang
Nanfeng Jiang
JVJordan Vincent
Jordan Vincent
ZSZhiyuan Song
Zhiyuan Song
XWXizhao Wang
Xizhao Wang

26 February 2020 in ChemRxiv
Verified
Preprint
Open access
PDF file
JVJordan Vincent
Jordan Vincent
HWHui Wang
Hui Wang
ONOmar Nibouche
Omar Nibouche
PMPAUL MAGUIRE
PAUL MAGUIRE
Trace methane detection in the parts per million range is reported using a novel detection scheme based on optical emission spectra from low temperature atmospheric pressure microplasmas. These bright low-cost plasma sources were operated under non-equilibrium conditions, producing spectra with a complex and variable sensitivity to trace levels of added gases. A data-driven machine learning approach based on Partial Least Squares Discriminant Analysis (PLS-DA) was implemented for CH4 concentrations up to 100 ppm in He, to provide binary classification of samples above or below a threshold of 2 ppm. With a low-resolution spectrometer and a custom spectral alignment procedure, a prediction accuracy of 98% was achieved, demonstrating the power of machine learning with otherwise prohibitively complex spectral analysis. This work establishes proof of principle for low cost and high-resolution trace gas detection with the potential for field deployment and autonomous remote monitoring.

26 November 2023
Verified
Book Chapter
Closed access
PDF file
JVJordan Vincent
Jordan Vincent
Joseph RaffertyJoseph Rafferty
Joseph Rafferty
MBMatthew Burns
Matthew Burns
Chris NugentChris Nugent
Chris Nugent