This work develops a needle insertion force model based on fracture mechanics, which incorporates the fracture toughness, shear modulus, and friction force of the needle and tissue. Ex vivo tissue experiments were performed to determine these mechanical tissue properties. A double insertion of the needle into the tissue was utilized to determine the fracture toughness. The shear modulus was found by applying an Ogden fit to the stress–strain curve of the tissue achieved through tension experiments. The frictional force was measured by inserting the needle through precut tissue. Results show that the force model predicts within 0.2 N of experimental needle insertion force and the fracture toughness is primarily affected by the needle diameter and needle edge geometry. On average, the tearing force was found to account for 61% of the total insertion force, the spreading force to account for 18%, and the friction force to account for the remaining 21%.

12 December 2011 in Medical Physics
Verified
Journal Article
Closed access
JMJason Z. Moore
Jason Z. Moore
PMPatrick W. McLaughlin
Patrick W. McLaughlin
ASAlbert J. Shih
Albert J. Shih

1 November 2017 in Journal of Surgical Education
Verified
Journal Article
Closed access
DPDavid F. Pepley
David F. Pepley
AGAdam B. Gordon
Adam B. Gordon
MYMary A. Yovanoff
Mary A. Yovanoff
KMKatelin A. Mirkin
Katelin A. Mirkin
SMScarlett R. Miller
Scarlett R. Miller
JMJason Z. Moore
Jason Z. Moore

1 June 2018 in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
Verified
Journal Article
Closed access
DPDavid Frederick Pepley
David Frederick Pepley
CSCheyenne Cassel Sonntag
Cheyenne Cassel Sonntag
RPRohan Sunil Bs Prabhu
Rohan Sunil Bs Prabhu
MYMary Alice Yovanoff
Mary Alice Yovanoff
DHDavid C. Han
David C. Han
JMJason Z. Moore
Jason Z. Moore
Introduction: Training using ultrasound phantoms allows for safe introduction to clinical skills and is associated with improved in-hospital performance. Many materials have been used to simulate human tissue in phantoms including commercial manikins, agar, gelatin, and Ballistics Gel; however, phantom tissues could be improved to provide higher-fidelity ultrasound images or tactile sensation. This article describes a novel phantom tissue mixture of a modified polyvinyl chloride (PVC) polymer, mineral oil, and chalk powder and evaluates needle cutting and ultrasonic properties of the modified PVC polymer mixture compared with a variety of phantom tissues. Methods: The first experiment measured axial needle forces of a needle insertion into nine phantom materials, including three formulations of modified PVC. The second experiment used a pairwise comparison survey of ultrasound images to determine the perceived realism of phantom ultrasound images. Results: It was found that the materials of Ballistics Gel and one of the PVC mixtures provide stiff force feedback similar to cadaver tissue. Other phantom materials including agar and gelatin provide very weak unrealistic force feedback. The survey results showed the PVC mixtures being viewed as the most realistic by the survey participants, whereas agar and Ballistics Gel were seen as the least realistic. Conclusions: The realism in cutting force and ultrasound visualization was determined for a variety of phantom materials. Novel modified PVC polymer has great potential for use in ultrasound phantoms because of its realistic ultrasound imaging and modifiable stiffness. This customizability allows for easy creation of multilayer tissue phantoms.

24 June 2016 in Journal of Manufacturing Science and Engineering
Verified
Journal Article
Open access
PDF file
ABAndrew C. Barnett
Andrew C. Barnett
JJJustin A. Jones
Justin A. Jones
YLYuan-Shin Lee
Yuan-Shin Lee
JMJason Z. Moore
Jason Z. Moore
This work investigates the performance of a novel compliant needle for cutting tissue. The novel cutting geometry transfers axial vibration to transverse motion at the tip. The cutting edge of the geometry is defined in terms of the time-dependent inclination and rake angle. Finite element analysis was performed to determine the compliant geometry effect on the axial vibration modes of the needles. An ultrasonic transducer is used to apply the axial vibration. An ultrasonic horn was developed to increase the amplitude of vibration. Experiments were performed to determine the effectiveness of the compliant needle geometry. The motion of the compliant needle is measured with a stereomicroscope. The two compliant geometries developed transverse motion of 4.5 μm and 16.0 μm. The control needle with fixed geometry developed no measured transverse motion. The insertion force was recorded for two different compliant geometries and a control geometry inserted into a polyurethane sheet. The puncture force of the control needle with applied vibration and the two compliant needles was up to 29.5% lower than the control insertion without applied vibration. The compliant needles reduced the friction force up to 71.0%. The significant reduction of the friction force is explained by the compliant needles' ability to create a larger crack in the material because of their transverse motion.

13 March 2020 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
ASAnkit Saxena
Ankit Saxena
EPEric M. Pauli
Eric M. Pauli
RHRandy S. Haluck
Randy S. Haluck
BFBarry Fell
Barry Fell
JMJason Z. Moore
Jason Z. Moore
Colonoscopy is a minimally invasive procedure to examine the large intestine using a flexible endoscope. Currently, colonoscopic procedures require physically pushing the endoscope through the large intestine which potentially imparts damaging forces on the intestinal wall, requires a high level of expertise to perform safely, and can require extensive procedure time. This paper presents the use of inverted tubular element locomotion (ITEL) for improved endoscope translation and positioning that works via tip eversion of inverted plastic tubes. Experiments were performed to examine the fluid pressure required for locomotion through a large intestinal model and in both straight and curved paths and determine the optimal tube dimensions for insertion via ITEL. Experiments were then performed to compare intestinal forces during manual and ITEL-based insertion. The experiments established a relationship between the tip eversion pressure and the tube thickness and diameter. In addition, it was found that pressure required for locomotion was only minimally impeded by being enclosed in the intestinal manikin but significantly impacted by the curvature of the turn. Measured insertion forces for ITEL were found to be 10.1% less compared to traditional insertion. These results will aid in the future design and development of ITEL for endoscopic positioning.