Hearing difficulty in noise can occur in 10–15% of listeners with typical hearing in the general population of the United States. Using one’s smartphone as a remote microphone (RM) system with the AirPods Pro (AP) may be considered an assistive device given its wide availability and potentially lower price. To evaluate this possibility, the accuracy of voice-to-text transcription for sentences presented in noise was compared, when KEMAR wore an AP receiver connected to an iPhone set to function as an RM system, to the accuracy obtained when it wore a sophisticated Phonak Roger RM system. A ten-sentence list was presented for six technology arrangements at three signal-to-noise ratios (SNRs; +5, 0, and −5 dB) in two types of noise (speech-shaped and babble noise). Each sentence was transcribed by Otter AI to obtain an overall percent accuracy for each condition. At the most challenging SNR (−5 dB SNR) across both noise types, the Roger system and smartphone/AP set to noise cancelation mode showed significantly higher accuracy relative to the condition when the smartphone/AP was in transparency mode. However, the major limitation of Bluetooth signal delay when using the AP/smartphone system would require further investigation in real-world settings with human users.
Purpose: The purpose of this study was to evaluate how the EasyGain settings on a wireless receiver used with a remote microphone (RM) affected output as a function of hearing loss and receiver type. Method: To assess the effects of the EasyGain setting on a Roger receiver, a Phonak Naida V90 superpower hearing aid (HA), two universal Roger X (02) receivers, two Roger 18 integrated receivers, and a Roger Inspiro transmitter were used. An electroacoustic evaluation was performed for five degrees of hearing loss ranging from a flat 40 to 80 dB HL, and for nine EasyGain settings from +8 to −8 dB with each Roger receiver. Results: A three-way analysis of variance indicated significant main effects of hearing loss, receiver type and EasyGain settings, as well as their two-way interactions ( p < .05). Overall, the output of the integrated receiver was 2.77 dB higher than that of the universal receiver. The change in output with 2-dB changes in EasyGain setting varied with the degree of hearing loss. For mild hearing loss (40 and 50 dB), every 2-dB change in EasyGain produced an average of 1.93 dB ( SD = 0.17) change in the root-mean-square (RMS) output. For the higher degrees of hearing loss (60, 70, and 80 dB HL), the change in RMS varied depending on the range of EasyGain setting as follows: when EasyGain was > 0 dB, every 2-dB change in EasyGain setting produced an average change in RMS output of 1.32 dB ( SD = 0.41); however, when EasyGain was ≤ 0 dB, every 2-dB change resulted in a mean 1.95 dB ( SD = 0.16) change. Conclusions: The benefits of EasyGain technology on the RMS output are dependent on the interaction of the receiver type, degree of hearing loss, and EasyGain settings. The results highlight the importance of electroacoustic verification to determine appropriate settings for optimal audibility when using an RM system.
Hearing difficulty in noise can occur to 10-15% of listeners with typical hearing in the general population of the United States. Using one’s smartphone as a remote microphone (RM) system with AirPods Pro (AP) may be considered as an assistive device given its wide availability and possible lower price. To evaluate this possibility, the accuracy of voice-to-text transcription for sentences presented in noise was compared when KEMAR wore an AP receiver connected to an iPhone set to function as an RM system to the accuracy obtained when he wore a sophisticated Phonak Roger RM system. A ten-sentence list was presented for six technology arrangements at three signal-to-noise ratios (SNR; +5, 0, and -5 dB) in two types of noise (speech-shaped and babble noise). Each sentence was transcribed by Otter AI to obtain an overall percent accuracy for each condition. At the most challenging SNR (-5 dB SNR) across both noise types, the Roger system and smartphone/AP set to noise cancellation mode showed significantly higher accuracy relative to the condition when smartphone/AP was in transparency mode. However, the major limitation of Bluetooth signal delay when using the AP/smartphone system would require further investigation in real-world settings with human users.
Listeners often struggle in noisy environments due to increased cognitive load (listening effort). While listening effort is a multidimensional construct evaluated using different metrics, the relationship among these metrics remains underexplored when conducted at participant equivalent performance levels. The purpose was to determine the relationship between self-reported hearing difficulty and physiologic state during challenging listening tasks that may lead to more sensitive measures of performance and ultimately more effective remedial strategies. This investigation involved listening effort measures via three concurrent non-invasive physiological modalities—pupillometry, electrodermal activity, and photoplethysmography—alongside self-reported hearing abilities in 33 young adults with typical hearing (M = 20.55 years). The noise level required for 75% speech recognition threshold was determined individually (SNR75). A second speech recognition task was presented at each individual’s SNR75 while the three physiologic metrics were recorded. These measures exhibited statistically significant changes from baseline to listening and response peaks across the time domain. Despite these universal main effects, the physiological measures showed no significant cross-modal correlations, nor did they align with self-reported hearing metrics. The results confirm that while these three sensor modalities are sensitive markers of task-evoked effort, they reflect fundamentally independent physiological axes of autonomic arousal during complex speech comprehension.
By individualizing speech-in-noise level, one can aim to compare physiological responses near a comparable recognition level across listeners with different hearing abilities. We examined whether the aim was realized and whether pupil diameter, skin conductance, and photoplethysmography-derived heartrate provided usable responses during sentence recognition. Thirty-three young adults with normal or near-normal audiograms repeated sentences in multitalker babble at individually calibrated levels. Code audit identified the calibration estimate as a model-based whole-sentence SNR50, rather than the intended SNR75. Actual whole-sentence accuracy averaged 43.6% (ranging from 20% to 70%). Relative to a 500 ms pre-speech reference, mean pupil change was 0.17 mm during encoding–retention (95% CI [0.13, 0.21]; n = 19) and 0.14 mm during verbal response ([0.08, 0.20]; n = 13). Corresponding skin-conductance changes were 0.02 μS ([0.01, 0.04]; n = 30) and 0.07 μS ([0.04, 0.09]; n = 30). Skin conductance was greater during verbal response, an interval also containing speech production, respiration, and movement; this contrast cannot isolate listening-related activity. No cross-modal or physiology–behavior association survived false-discovery-rate correction. The short reference did not support heart-rate change estimation. Individual calibration provided an approximate performance anchor but did not verify equivalent observed performance or effort. The data describe stage-related pupil and conductance reactivity but cannot rank modalities by sensitivity to changing listening demand.
Background/Objectives: Previous research has shown that listeners may use acoustic cues for speech processing that are perceived during brief segments in the noise when there is an optimal signal-to-noise ratio (SNR). This “glimpsing” effect requires higher cognitive skills than the speech tasks used in typical audiometric evaluations. Purpose: The aim of this study was to investigate the use of an online test of speech processing in noise in listeners with typical hearing sensitivity (TH, defined as thresholds ≤ 25 dB HL) who were asked to determine the gender of the subject in sentences that were presented in increasing levels of continuous and interrupted noise. Methods: This was a repeated-measures design with three factors (SNR, noise type, and syntactic complexity). Study Sample: Participants with self-reported TH (N = 153, ages 18–39 years, mean age = 20.7 years) who passed an online hearing screening were invited to complete an online questionnaire. Data Collection and Analysis: Participants completed a sentence recognition task under four SNRs (−6, −9, −12, and −15 dB), two syntactic complexity settings (subjective-relative and objective-relative center-embedded), and two noise types (interrupted and continuous). They were asked to listen to 64 sentences through their own headphones/earphones that were presented in an online format at a user-selected comfortable listening level. Their task was to identify the gender of the person performing the action in each sentence. Results: Significant main effects of all three factors as well as the SNR by noise-type two-way interaction were identified (p < 0.05). This interaction indicated that the effect of SNR on sentence comprehension was more pronounced in the continuous noise compared to the interrupted noise condition. Conclusions: Listeners with self-reported TH benefited from the glimpsing effect in the interrupted noise even under low SNRs (i.e., −15 dB). The evaluation of glimpsing may be a sensitive measure of auditory processing beyond the traditional word recognition used in clinical evaluations in persons who report hearing challenges and may hold promise for the development of auditory training programs.