Carsten Thirstrup

Dr. Carsten Thirstrup


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CTCarsten Thirstrup
Carsten Thirstrup
LDLisa Deleebeeck
Lisa Deleebeeck
Electrolytic conductivity (EC) sensors are widely used in diverse industries, including: pharmaceuticals, food, power, manufacturing, and environmental monitoring. This article presents an overview and analysis of EC sensors used in these industries from the lowest to the highest range of conductivities and in applications, where there are strong requirements for accurate and traceable conductivity measurements of water and electrolyte solutions. Included are reported sensor designs based on two- and four-electrodes with parallel plates, coaxial cylinders, van der Pauw configurations, planar and miniature configurations, and contactless inductive or capacitive coupling. A comprehensive list of exact analytical formulas for computation of cell constants for the configurations is provided. The advantages and disadvantages of using frequency domain or time domain measurement schemes in these sensors are discussed, and the reader is guided to select the suitable method of sensor calibration among the methods available, computing uncertainty budgets, ensuring traceability to the International System of Units (SI) and compliance with standards, such as Pharmacopeias. Finally, trends in the development of EC sensors and the related challenges in relation to calibration and compliance with standards are presented. This article also introduces the reader to the EC cell of a sensor, which can be modeled by solving the Poisson-Nernst-Planck equations or using appropriate equivalent circuit diagrams. It is stepwise described how the models can be extended to include effects such as electrode polarization and steric effects of ions, and it is illustrated by means of an ideal EC cell, where guards eliminate fringe fields, that the simplest equivalent circuit with a single resistor and a single capacitor models electrolytic sensor data very well in the lower range of electrolytic conductivities.

4 July 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CTCarsten Thirstrup
Carsten Thirstrup
ASAlan Snedden
Alan Snedden
HJHans D. Jensen
Hans D. Jensen
This paper reports a closed-flow-loop electrolytic conductivity measurement system enabling calibration of conductivity sensors from the conductivity level of ultrapure water (UPW) at 5.5 μS/m up till the range of 10 to 140 mS/m, where stable certified reference materials (CRMs) for conductivity are available. The system is traceable to the SI unit system. A comparison made with another electrolytic conductivity measurement system, which is based on Jones-type conductivity cells designed to be used primarily for conductivities larger than ~10 mS/m, shows an agreement better than 0.1%. The most commonly used calibration method of conductivity sensors is based on CRMs and the extrapolation of the data to low conductivity values (<;1000 μS/m). In contrast, the present closedflow-loop electrolytic conductivity measurement system is based on the measurements made at conductivity levels where the sensor is used; it is, therefore, a better alternative.

1 July 1993 in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
Verified
Journal Article
Closed access
CTCarsten Thirstrup
Carsten Thirstrup
Stella W. PangStella W. Pang
Stella W. Pang
OAO. Albrektsen
O. Albrektsen
JHJ. Hanberg
J. Hanberg

14 November 2017 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
CTCarsten Thirstrup
Carsten Thirstrup
ASAlan Snedden
Alan Snedden
LDLisa Deleebeeck
Lisa Deleebeeck
This paper addresses the challenges of making accurate and traceable electrolytic conductivity cell constant calibrations and sensor system calibration measurements over a wide range of conductivity, from 5.5 µ S m −1 (ultrapure water) up to 140 000 µ S m −1 , where stable and reliable commercial certified reference materials (CRMs) are available. The challenges of making electrolytic conductivity measurements in the time domain versus the frequency domain are discussed and the relationship between the two domains is analysed in terms of a Gaver–Stehfest algorithm for inverse Laplace transform. Data from a commercial current-step-pulse-based sensor reader operating in the time domain are compared with accurate and traceable data from a closed-flow-loop electrolytic conductivity measurement system operating in the frequency domain and traceable to the SI length unit. In the high conductivity range, the readouts of the sensor reader are observed to deviate from traceable conductivity values by up to 10 times the estimated standard measurement uncertainty, which is in the range 0.07%–0.17%. If accurate conductivity calibrations are required (<1%), the usual method of calibrating a conductivity sensor system at a high conductivity level, where CRMs are available, and relying on the same calibration for low conductivity measurements is, therefore, risky.

8 August 2019 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
CTCarsten Thirstrup
Carsten Thirstrup
LDLisa Carol Deleebeeck
Lisa Carol Deleebeeck
ALAntonio Marcus Nogueira Lima
Antonio Marcus Nogueira Lima
A sensitive, ion-specific measurement scheme is proposed and analysed theoretically. It is based on transit-time surface plasmon resonance (SPR) sensing in an electrolytic conductivity cell comprising an electrode supporting surface plasmons (SPs). The transit-time SPR response involves dynamics of ion transport in the electrolytic conductivity cell and a highly sensitive SPR response from the electrode supporting SPs. This is modelled by solving the modified-Poisson–Nernst–Planck equations and the Fresnel equations. It is shown that the magnitude of the transit-time SPR detection signal scales with the square root of ion concentration ( ), whilst bulk SPR detection scales linearly with ion concentration ( ). Transit-time SPR is, therefore, a superior detection scheme at low ion concentrations. Analyses by Tikhonov regularization show that transit-time SPR response enables specific ion detection through differences in ion mobility and charge. The proposed method is purely physical, not requiring chemical affinity layers or chemical reduction-oxidation processes at the electrodes. It is based on a differential measurement scheme with and without voltage applied. Compared to conductivity sensors, the method adds specificity, while compared to bulk SPR sensors, it improves the resolution at low concentration levels and enables specificity without use of surface chemistry or biochemistry.

1 March 2014 in NCSLI Measure
Verified
Journal Article
Closed access
HJHans D. Jensen
Hans D. Jensen
CTCarsten Thirstrup
Carsten Thirstrup
Danish Fundamental Metrology (DFM) has established a calibration setup with direct International System (SI) traceability for conductivity sensors and measurement systems for conductivity of pure to ultra-pure water. Electrolytic conductivity is a widely used parameter for the characterization of purity of water, due to its high sensitivity to ionic content e.g. from contaminants. The Pharmacopoeias (US, EU, etc.) specify (traceable) conductivity measurements as the method for documenting compliance with requirements of Water for Injection (WFI), and other regulations on pure water quality also rely on conductivity as the quality parameter. Conductivity sensors are presently calibrated either using reference materials with conductivity many orders of magnitude different from the level of measurement, and/or in a matrix different (sometimes very different) from pure water. Some users rely on indirect properties such as the conductivity temperature coefficient of water as a quality control parameter. DFM has developed a geometrically characterized measurement cell, hence a primary standard, relevant for pure water conductivity. Combined with a bulk resistance derived from impedance spectroscopy, also traceable to international standards, it allows direct measurement of low conductivity (less than 2 mS/m). A calibration setup with comparison to the primary cell establishes direct traceability to the SI, without the need for assumptions on scaling properties of conductivity cells or insignificant matrix effects. The setup has been validated through an international measurement comparison at the national metrology institute (NMI) level.