Complex stereotactic radiotherapy treatment plans require prior verification. A gel dosimetry system was developed and tested to serve as a high-resolution 3D dosimeter for Quality Assurance (QA) purposes. A modified version of a polyacrylamide polymer gel dosimeter based on chemical response inhibition was employed. Different sample geometries (cuvettes and phantoms) were manufactured for calibration and QA acquisitions. Irradiations were performed with a Varian Trilogy linac, and analyses of irradiated gel dosimeters were performed via MRI with a 1.5 T Philips Achieva at 1 mm3 or 2 mm3 isotropic spatial resolution. To assess reliability of polymer gel data, 54 stereotactic clinical treatment plans were delivered both on dosimetric gel phantoms and on the Delta4 dosimeter. Results from the two devices were evaluated through a global gamma index over a range of acceptance criteria and compared with each other. A quantitative and tunable control of dosimetric gel response sensitivity was achieved through chemical inhibition. An optimized MRI analysis protocol allowed to acquire high resolution phantom dose data in timeframes of ≈ 1 h. Conversion of gel dosimeter data into absorbed dose was achieved through internal calibration. Polymer gel dosimeters (2 mm3 resolution) and Delta4 presented an agreement within 4.8 % and 2.7 % at the 3 %/1 mm and 2 %/2 mm gamma criteria, respectively. Gel dosimeters appear as promising tools for high resolution 3D QA. Added complexity of the gel dosimetry protocol may be justifiable in case of small target volumes and steep dose gradients.
3 October 2018 in Radiation Effects and Defects in Solids
Polymer gel dosimeters represent a promising instrument for tridimensional radiation dose measurement for highly conformal radiation therapy techniques. In this study, the dependence of the dose response of the polymeric gel dosimeter PAGAT was investigated as a function of different irradiation conditions and time elapsed after irradiation. An X-ray tube and 60Co sources were used for irradiation. This allowed to assess variations in system dose response under different irradiation energies and dose rates - ranging from 1.4 Gy h-1 up to 0.14 kGy h−1. Analysis of irradiated samples was performed by UV–Vis optical measurements at different time intervals after irradiation. Significant variability in PAGAT dose response was observed for different irradiation conditions and considered dose rates.
11 May 2025 in Industrial & Engineering Chemistry Research
Large amounts of spent, radioactive, ion-exchange resins have been generated worldwide, and their production is expected to grow due to a renaissance of nuclear power. Such waste is being stored at individual plant sites around the world, awaiting a reliable disposal route to overcome the downsides of the state-of-the-art management approaches. In this work, a first-of-its-kind pre-disposal strategy is proposed, based on the integration of a heterogeneous Fenton-like treatment with conditioning in an alkali-activated matrix. In particular, the circular economy is pursued by repurposing two industrial by-products, coal fly ash and steel slag, both as catalysts of the Fenton treatment and precursors of the conditioning matrix. The obtained waste forms have been preliminarily tested for leaching and compressive strength according to the Italian waste acceptance criteria for disposal. The proposed technology, tested at laboratory scale up to 100 g of virgin cationic resin, has proven successful in decomposing the waste and synthesizing waste forms with an overall volume increase of only 30%, thereby achieving a remarkable result compared to state-of-the-art technologies.