Giulia Maria Liosi

Giulia Maria Liosi

Auto-generated profile, based on publicly available information

Giulia Maria Liosi

Department of Energy, Politecnico di Milano, Milano, Italy

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2018 in Radiation Effects and Defects in Solids
Verified
Journal Article
Closed access
GMGabriele Magugliani
Gabriele Magugliani
GLG. M. Liosi
G. M. Liosi
DTD. Tagliabue
D. Tagliabue
EMEros Mossini
Eros Mossini
MNMaddalena Negrin
Maddalena Negrin
MMMariani Mario
Mariani Mario
Polymer gel dosimeters represent a promising instrument for tridimensional radiation dose measurement for highly conformal radiation therapy techniques. In this study, the dependence of the dose response of the polymeric gel dosimeter PAGAT was investigated as a function of different irradiation conditions and time elapsed after irradiation. An X-ray tube and 60Co sources were used for irradiation. This allowed to assess variations in system dose response under different irradiation energies and dose rates - ranging from 1.4 Gy h-1 up to 0.14 kGy h−1. Analysis of irradiated samples was performed by UV–Vis optical measurements at different time intervals after irradiation. Significant variability in PAGAT dose response was observed for different irradiation conditions and considered dose rates.

1 September 2015 in Nukleonika
Verified
Journal Article
Open access
PDF file
GLGiulia Maria Liosi
Giulia Maria Liosi
FGFrancesca Celsa Giacobbo
Francesca Celsa Giacobbo
EPEmanuele Pignoli
Emanuele Pignoli
MCMauro Carrara
Mauro Carrara
GGGrazia Gambarini
Grazia Gambarini
MMMariani Mario
Mariani Mario
The Fricke xylenol orange (FX) gel system is a chemical dosimeter characterized by good sensitivity, linear dose response, tissue equivalence, no toxicity, easy preparation, reproducibility and low cost. Thanks to the presence of the gelatinous matrix, the system is particularly suitable to perform reliable 3D mapping of the absorbed dose spatial distribution via magnetic resonance imaging (MRI) or optical techniques. The aim of this work is to study in a systematic way the influence of the pre-irradiation storage procedure upon sensitivity, dose response stability and lifetime of use of a FX gel system made with gelatin from porcine skin subjected to homogeneous irradiation. For this purpose, different pre-irradiation storage procedures, in terms of temperature and duration of each storage step, were investigated. In order to evaluate the dose response stability, the optical analyses of the samples were performed up to 6 hours after irradiation. Moreover, the samples were irradiated at time intervals of 24 hours for up to 7 days after preparation in order to evaluate the system lifetime of use. Regardless of their thermal and temporal life, the samples show linear dose responses in the investigated dose range (3-24 Gy) and an increase of sensitivity with the time elapsed between preparation and irradiation. Among the three pre-irradiation storage procedures considered here, a procedure that provides the best dose response stability and lifetime of use was identified and recommended for further use. The analyzed dosimetric system possesses good properties that make it promising for medical application, particularly concerning the evaluation of pre-treatment plan quality assurance within the conformational external beam radiotherapy

20 July 2018 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
GLGiulia Maria Liosi
Giulia Maria Liosi
GGGrazia Gambarini
Grazia Gambarini
EAEmanuele Artuso
Emanuele Artuso
SBSara Benedini
Sara Benedini
EMElena Macerata
Elena Macerata
MMMariani Mario
Mariani Mario
The response of Fricke xylenol orange gelatin dosimeter has been studied to investigate the possibility of achieving a calibration method based on a preirradiation procedure. With this aim, different preirradiation parameters have been tested, and the system response to subsequent irradiations has been investigated. Both Fricke gel layers and cuvettes were considered, and no dependence on shape and wall material was observed. An increase of the system response was observed, depending on the total absorbed dose and not on the number of subsequent irradiations performed, as evidenced by the changes of the absorption spectra shapes. Moreover, different calibration curves, and consequently different sensitivities, were obtained with different preirradiation parameters. In order to propose a calibration procedure, further studies are of fundamental importance to deeper comprehending the influence of preirradiation parameters on the system sensitivity and response. In particular, a systematic analysis of the whole absorption spectra has proved to be central.