Byung-Gyu Yu

Dr. Byung-Gyu Yu

Division of Electrical Electronics and Control Engineering,Kongju National University, Chungnam 331-717, Korea
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2018 in Electronics
Verified
Journal Article
Open access
PDF file
Byung-Gyu YuByung-Gyu Yu
Byung-Gyu Yu
The Phase Locked Loop (PLL) technique has been studied to obtain the phase and frequency information in grid-connected distributed generations for the sake of synchronizing the grid voltage and the inverter output current. In particular, the line frequency information, such as the anti-islanding function, is very important for the grid connection requirement. This paper presents a novel frequency measurement method from the digital PLL control structure for single-phase grid-connected PV applications. The conventional PLL controller uses the phase information to calculate the frequency of PV inverter output voltage after every line cycle and has shown a relatively low accuracy. This paper uses the angular frequency to directly measure the frequency after every line cycle. To verify the validity of the proposed method compared with the conventional method, a simulation was conducted. According to the simulation results, the measurement error of the proposed method is 80 times lower than the conventional one.

4 May 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
Ahmed AbokhalilAhmed Abokhalil
Ahmed Abokhalil
AQAbdel-Rahman Al Qawasmi
Abdel-Rahman Al Qawasmi
Ali EltamalyAli Eltamaly
Ali Eltamaly
Byung-Gyu YuByung-Gyu Yu
Byung-Gyu Yu
Since the lifespan of an electrolytic capacitor is relatively short compared to other power semiconductor devices, the failure rate accounts for 60% and, thus, it is the most vulnerable component of the power conversion device. Therefore, the accurate measurement of the lifetime of an electrolytic capacitor is very important in ensuring the reliability of the entire system, including the capacitor. In this paper, an online failure detection method for a DC-link electrolytic capacitor in a back-to-back Pulse width Modulation (PWM) converter using the opposition-based learning particle swarm optimization-based Support Vector Regression (OPSO-SVR) technique is proposed. In this method, the capacitance and the DC-link capacitor power have been used in offline mode for SVR training and testing. During the offline mode, the SVR parameters have been optimized with the OPSO algorithm to use online to estimate the real value of the DC-link capacitor. The experimental results prove the superiority of the proposed technique over the SVR.

27 October 2016 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
Byung-Gyu YuByung-Gyu Yu
Byung-Gyu Yu
Nowadays, many countries have paid attention to renewable energy due to fossil fuel crisis and its related environmental pollution. In particular, following the government supply business for renewable energy industry, the private sectors drive the stable power supply by using renewable sources for both microgrid system and standalone application. Battery charging and discharging control system of microgrid system are critical to extend lifetime of standalone photovoltaic system. Corresponding to this demand, this paper presents the development of battery charging and discharging system based on battery modeling, SOC (state of charge) estimation, and its implementation for 5 kW. As a result, the conversion efficiency shows 96.35% with over 95% charging performance.

5 June 2014 in IEEJ Transactions on Electrical and Electronic Engineering
Verified
Journal Article
Closed access
PDF file
Byung-Gyu YuByung-Gyu Yu
Byung-Gyu Yu

21 September 2017 in IETE Journal of Research
Verified
Journal Article
Closed access
Byung-Gyu YuByung-Gyu Yu
Byung-Gyu Yu
The islanding phenomenon of a distributed resource (DR), like a photovoltaic (PV) system or an energy storage system (ESS), is one of the major issues about the increased DR in distributed power networks because it causes a safety hazard to a power system's service personnel and the related power facility by unexpected powering. To prevent islanding, many anti-islanding methods have been developed and evaluated by the international and domestic grid-interconnection standards, but they have mostly focused on a single DR unit. Until now, evaluating the anti-islanding function for multiple DRs connected to the same power grid has received little attention. The rapid deployment of the PV micro-inverter in recent years has substantially increased the likelihood and concerns associated with islanding, especially with multiple operations in the same grid. This paper presents an anti-islanding performance analysis of multiple PV micro-inverter operations. Various islanding cases for multiple PV micro-inverter systems are evaluated based on the existing standard with the appropriate modification.

24 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Byung-Gyu YuByung-Gyu Yu
Byung-Gyu Yu
Islanding phenomenon of distributed generation (DG), such as photovoltaic (PV) generation, is undesirable because it causes safety issues for utility service personnel and power system equipment. Many anti-islanding methods have been studied since DG appeared in electric power systems (EPSs). Most anti-islanding methods focus on disconnecting DG from the grid using functionality to detect islanding under narrow frequency trip settings, because safety issues have a higher priority. However, as DG plays a key part of an EPS, a significant loss of DG due to a short disturbance could result in a reliability issue for the EPS. Corresponding to this matter, new international standards, such as IEEE standard 1547–2018, require more sophisticated and complex functionalities for grid-connected DGs by adopting ride-through technologies and wider voltage/frequency trip settings. Since most anti-islanding functions of inverter-based DG have been based on the frequency of the inverter voltage, it is more difficult to detect islanding under wider frequency trip settings. This paper presents a correlation-based anti-islanding method (AIM) without depending on the frequency trip of inverter-based DGs. Simulation results are provided to verify the performance of the correlation-based anti-islanding method. As a result, the proposed method detects islanding at 0.116 s under wider frequency trip setting by the IEEE Std. 1547–2018 test condition, while the popular active frequency drift method with positive feedback does not detect islanding using the same current disturbance.