Mohammad Robiul Hossan

Dr. Mohammad Robiul Hossan

Department of Engineering and Physics, University of Central Oklahoma, Edmond, OK 73034, USA
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
PKPrashanth Reddy Konari
Prashanth Reddy Konari
YCYung-Dai Clayton
Yung-Dai Clayton
Melville B VaughanMelville B Vaughan
Melville B Vaughan
MKMorshed Khandaker
Morshed Khandaker
Mohammad Robiul HossanMohammad Robiul Hossan
Mohammad Robiul Hossan
Laser micromachining technique offers a promising alternative method for rapid production of microfluidic devices. However, the effect of process parameters on the channel geometry and quality of channels on common microfluidic substrates has not been fully understood yet. In this research, we studied the effect of laser system parameters on the microchannel characteristics of Polydimethylsiloxane (PDMS), polymethyl methacrylate (PMMA), and microscope glass substrate—three most widely used materials for microchannels. We also conducted a cell adhesion experiment using normal human dermal fibroblasts on laser-machined microchannels on these substrates. A commercial CO2 laser system consisting of a 45W laser tube, circulating water loop within the laser tube and air cooling of the substrate was used for machining microchannels in PDMS, PMMA and glass. Four laser system parameters—speed, power, focal distance, and number of passes were varied to fabricate straight microchannels. The channel characteristics such as depth, width, and shape were measured using a scanning electron microscope (SEM) and a 3D profilometer. The results show that higher speed produces lower depth while higher laser power produces deeper channels regardless of the substrate materials. Unfocused laser machining produces wider but shallower channels. For the same speed and power, PDMS channels were the widest while PMMA channels were the deepest. Results also showed that the profiles of microchannels can be controlled by increasing the number of passes. With an increased number of passes, both glass and PDMS produced uniform, wider, and more circular channels; in contrast, PMMA channels were sharper at the bottom and skewed. In rapid cell adhesion experiments, PDMS and glass microchannels performed better than PMMA microchannels. This study can serve as a quick reference in material-specific laser-based microchannel fabrications.

14 February 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
MBMatthew Benton
Matthew Benton
Mohammad Robiul HossanMohammad Robiul Hossan
Mohammad Robiul Hossan
PKPrashanth Reddy Konari
Prashanth Reddy Konari
SGSanjeewa Gamagedara
Sanjeewa Gamagedara
Laser micromachining has emerged as a promising technique for mass production of microfluidic devices. However, control and optimization of process parameters, and design of substrate materials are still ongoing challenges for the widespread application of laser micromachining. This article reports a systematic study on the effect of laser system parameters and thermo-physical properties of substrate materials on laser micromachining. Three dimensional transient heat conduction equation with a Gaussian laser heat source was solved using finite element based Multiphysics software COMSOL 5.2a. Large heat convection coefficients were used to consider the rapid phase transition of the material during the laser treatment. The depth of the laser cut was measured by removing material at a pre-set temperature. The grid independent analysis was performed for ensuring the accuracy of the model. The results show that laser power and scanning speed have a strong effect on the channel depth, while the level of focus of the laser beam contributes in determining both the depth and width of the channel. Higher thermal conductivity results deeper in cuts, in contrast the higher specific heat produces shallower channels for a given condition. These findings can help in designing and optimizing process parameters for laser micromachining of microfluidic devices.


1 October 2016 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
Mohammad Robiul HossanMohammad Robiul Hossan
Mohammad Robiul Hossan
PGPartha P. Gopmandal
Partha P. Gopmandal
RDRobert Dillon
Robert Dillon
PDPrashanta Dutta
Prashanta Dutta

12 November 2021 in Bioengineering
Verified
Journal Article
Open access
PDF file
KHKaitlyn B Hill
Kaitlyn B Hill
SHSeth Harriet
Seth Harriet
Vishal A BarotVishal A Barot
Vishal A Barot
ABAndrew Bauer
Andrew Bauer
Melville B VaughanMelville B Vaughan
Melville B Vaughan
Mohammad Robiul HossanMohammad Robiul Hossan
Mohammad Robiul Hossan
The flow diverting stent (FDS) has become a promising endovascular device for the treatment of aneurysms. This research presents a novel biodegradable and non-braided Polycaprolactone (PCL) FDS. The PCL FDS was designed and developed using an in-house fabrication unit and coated on two ends with BaSO4 for angiographic visibility. The mechanical flexibility and quality of FDS surfaces were examined with the UniVert testing machine, scanning electron microscope (SEM), and 3D profilometer. Human umbilical vein endothelial cell (HUVEC) adhesion, proliferation, and cell morphology studies on PCL FDS were performed. The cytotoxicity and NO production by HUVECs with PCL FDS were also conducted. The longitudinal tensile, radial, and bending flexibility were found to be 1.20 ± 0.19 N/mm, 0.56 ± 0.11 N/mm, and 0.34 ± 0.03 N/mm, respectively. The FDS was returned to the original shape and diameter after repeated compression and bending without compromising mechanical integrity. Results also showed that the proliferation and adhesion of HUVECs on the FDS surface increased over time compared to control without FDS. Lactate dehydrogenase (LDH) release and NO production showed that PCL FDS were non-toxic and satisfactory. Cell morphology studies showed that HUVECs were elongated to cover the FD surface and developed an endothelial monolayer. This study is a step forward toward the development and clinical use of biodegradable flow diverting stents for endovascular treatment of the aneurysm.

11 November 2019
Verified
Conference Paper
Closed access
PDF file
Mohammad Robiul HossanMohammad Robiul Hossan
Mohammad Robiul Hossan
NINazmul Islam
Nazmul Islam
Class performance and classroom environment have a direct impact on students’ learning and long-term retention of key engineering concepts. In addition, class performance is critical for preserving students’ interest and continuous engagement. However, engineering classes are widely rated as boring and monotonous by students due to one-way lectures and lack of application of active learning techniques. In this study, we employed mock tests as an active learning technique to empower students on their own learning through identification of conceptual weakness, reinforcement of understanding and hence, to improve their overall learning and class performance in two different engineering classes at two different universities. Mock tests were conducted on the exam materials before the occurrence of the actual exams. The mock test key with grading rubric was provided to the students. Students were required to grade their mock test based on the rubric. The impact of this technique is evaluated using questionnaires where students were asked to provide their feedback on the enhancement of their understanding of the material, understanding of grading criteria, improvement on their study habits, and identifying conceptual weakness about a topic. The assessment and student feedback shows that the use of the mock test improves the understanding of basic concepts and topics through perspective transformation. It also shows that it improves the average grade of the class, motivates students to study hard, promotes peer discussion, reduces exam related stresses, and strengthens fellowship among students. Thus, mock tests can be used in other disciplines and classes with similar positive effect.