Wearable and lightweight devices facilitate real-world physical activity (PA) assessments. MX metrics, as a cut-point-free parameter, evaluate acceleration above which the most active X minutes are accumulated. It provides insights into the intensity of PA over specific durations. This study evaluated the association of MX metrics and clinical tests in older adults recovering from proximal femoral fracture (PFF). Analyses were conducted on the PFF cohort from the baseline assessment of the Mobilise-D project using an accelerometer-based device. Participants (N = 396) were categorized into four recovery groups: acute, post-acute, extended recovery, and long-term recovery. Mobility capacity was assessed through the 6 min walking test (6MinWT), Short Physical Performance Battery (SPPB), 4-m walking test (4MWT), and hand grip (HG) strength. Mobility perception was evaluated using the Late-Life Function and Disability Instrument (LLFDI). Eight MX metrics (M1–M90) were calculated using the GGIR package in R. Results showed a moderate to strong positive correlation between M1 and M30 and lower limb mobility capacity tests and mobility perception (Lower Extremity domains) particularly in the extended and long-term recovery groups. MX metrics can be used for measuring PA intensity among older adults recovering from PFF. Hence, MX metrics have a high potential for clinical use as personalized PA targets in PFF rehabilitation.
Background/Objectives: The burden of disease caused by fragility fractures, and hip fractures in particular, is significant both from a personal and a societal perspective. Digital technologies such as wearable devices now allow a real-world assessment of walking and physical mobility, describing temporal and spatial measures. Built on a transparent technical validation, the Mobilise-D consortium validated a set of digital mobility outcomes (DMOs) alongside a longitudinal Clinical Validation Study (CVS). This article provides a description of DMOs along with supervised mobility assessment and patient-reported outcomes collected at entry of the CVS study in a sample of home-dwelling participants with a proximal femoral fracture (PFF) recruited within one year from surgery. Methods: Participants who underwent surgical treatment for a low-energy PFF were recruited from five sites in three high-income European countries. The baseline visit encompassed a clinical assessment (~3 hours) and subsequent 7-day measurement of real-world mobility with a single wearable device. We categorized participants into four recovery phases according to the assessment time after surgery: acute phase (≤14 days after surgery, hospital stay), post-acute phase (15-42 days after surgery, mostly rehabilitation), extended recovery phase (43 – 182 days post-surgery, typically post-discharge at home) and long-term recovery phase (183 – 365 days post-surgery). All variables were reported descriptively for each phase using mean and standard deviation or median and 25th-75th percentile depending on their distribution. Results: We enrolled 564 PFF participants (66% women). The mean age was 77.5 (SD 9.6) years. Almost 90% of all participants (n=505) had a valid digital mobility assessment (wear time of >12 hours per day and at least 3 valid days). DMO domains such as amount (e.g. number of steps), pace (e.g. walking speed) and pattern (bout distribution) demonstrated large differences across phases. Conclusions: The observed variation in walking amount, pace and pattern across recovery phases indicate that DMOs provide a granular analysis of real-world mobility of hip fracture survivors. When confirmed by longitudinal analyses, including results on minimal important differences, the use of selected DMOs will provide a novel approach for monitoring, predictive modeling, prognosis, stratification and evaluation of clinical trials and hip fracture services.