Ayyappasamy Sudalaiyadum Perumal

Dr. Ayyappasamy Sudalaiyadum Perumal

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2021 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
VTViola Tokárová
Viola Tokárová
APAyyappasamy Sudalaiyadum Perumal
Ayyappasamy Sudalaiyadum Perumal
MNMonalisha Nayak
Monalisha Nayak
HSHenry Shum
Henry Shum
OKOndřej Kašpar
Ondřej Kašpar
Dan V. NicolauDan V. Nicolau
Dan V. Nicolau
Understanding the motility behavior of bacteria in confining microenvironments, in which they search for available physical space and move in response to stimuli, is important for environmental, food industry, and biomedical applications. We studied the motility of five bacterial species with various sizes and flagellar architectures (Vibrio natriegens, Magnetococcus marinus, Pseudomonas putida, Vibrio fischeri, and Escherichia coli) in microfluidic environments presenting various levels of confinement and geometrical complexity, in the absence of external flow and concentration gradients. When the confinement is moderate, such as in quasi-open spaces with only one limiting wall, and in wide channels, the motility behavior of bacteria with complex flagellar architectures approximately follows the hydrodynamics-based predictions developed for simple monotrichous bacteria. Specifically, V. natriegens and V. fischeri moved parallel to the wall and P. putida and E. coli presented a stable movement parallel to the wall but with incidental wall escape events, while M. marinus exhibited frequent flipping between wall accumulator and wall escaper regimes. Conversely, in tighter confining environments, the motility is governed by the steric interactions between bacteria and the surrounding walls. In mesoscale regions, where the impacts of hydrodynamics and steric interactions overlap, these mechanisms can either push bacteria in the same directions in linear channels, leading to smooth bacterial movement, or they could be oppositional (e.g., in mesoscale-sized meandered channels), leading to chaotic movement and subsequent bacterial trapping. The study provides a methodological template for the design of microfluidic devices for single-cell genomic screening, bacterial entrapment for diagnostics, or biocomputation. Significance Understanding bacterial movement is crucial for health, agriculture, environment, and industry. Studying the motility of five bacterial species in microfluidic environments showed that bacterial motility behavior is the result of a “tug-of-war” between hydrodynamics and local nanomechanics. In less confining spaces, bacterial motility is governed by hydrodynamics and can be approximately predicted by modeling developed for the simplest species. Conversely, in tightly confining environments, movement is mainly controlled by the steric interactions between flagella and the surrounding walls. Intriguingly, in mesoscale-sized geometries, hydrodynamics and bacterium–wall interactions overlap, either “constructively,” leading to smooth movement in straight channels, or “destructively,” leading to trapping. Our study provides a methodological template for the development of devices for single-cell genomics, diagnostics, or biocomputation.

1 August 2012 in Waste Management
Verified
Journal Article
Closed access
BBBharathiraja Balasubramaniam
Bharathiraja Balasubramaniam
APAyyappasamy Sudalaiyadum Perumal
Ayyappasamy Sudalaiyadum Perumal
JJJayamuthunagai Jayaraman
Jayamuthunagai Jayaraman
JMJayakumar Mani
Jayakumar Mani
PRPraveenkumar Ramanujam
Praveenkumar Ramanujam

13 August 2014 in Nucleic Acids Research
Verified
Journal Article
Open access
PDF file
YHYangbo Hu
Yangbo Hu
ZMZakia Morichaud
Zakia Morichaud
APAyyappasamy Sudalaiyadum Perumal
Ayyappasamy Sudalaiyadum Perumal
FRFrançoise Roquet-Baneres
Françoise Roquet-Baneres
KBKonstantin Brodolin
Konstantin Brodolin
RbpA, a transcriptional activator that is essential for Mycobacterium tuberculosis replication and survival during antibiotic treatment, binds to RNA polymerase (RNAP) in the absence of promoter DNA. It has been hypothesized that RbpA stimulates housekeeping gene expression by promoting assembly of the σA subunit with core RNAP. Here, using a purified in vitro transcription system of M. tuberculosis, we show that RbpA functions in a promoter-dependent manner as a companion of RNAP essential for promoter DNA unwinding and formation of the catalytically active open promoter complex (RPo). Screening for RbpA activity using a full panel of the M. tuberculosis σ subunits demonstrated that RbpA targets σA and stress-response σB, but not the alternative σ subunits from the groups 3 and 4. In contrast to σA, the σB subunit activity displayed stringent dependency upon RbpA. These results suggest that RbpA-dependent control of RPo formation provides a mechanism for tuning gene expression during the switch between different physiological states, and in the stress response.

21 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
TTTomoo Tsuzuki
Tomoo Tsuzuki
KBKarine Baassiri
Karine Baassiri
ZMZahra Mahmoudi
Zahra Mahmoudi
APAyyappasamy Sudalaiyadum Perumal
Ayyappasamy Sudalaiyadum Perumal
KRKavya Rajendran
Kavya Rajendran
Dan V. NicolauDan V. Nicolau
Dan V. Nicolau
Polydimethylsiloxane (PDMS), a silicone elastomer, is increasingly being used in health and biomedical fields due to its excellent optical and mechanical properties. Its biocompatibility and resistance to biodegradation led to various applications (e.g., lung on a chip replicating blood flow, medical interventions, and diagnostics). The many advantages of PDMS are, however, partially offset by its inherent hydrophobicity, which makes it unsuitable for applications needing wetting, thus requiring the hydrophilization of its surface by exposure to UV or O2 plasma. Yet, the elastomeric state of PDMS translates in a slow, hours to days, process of reducing its surface hydrophilicity—a process denominated as hydrophobic recovery. Using Fourier transform infrared spectroscopy (FTIR) and atomic force microscopy (AFM), the present study details the dynamics of hydrophobic recovery of PDMS, on flat bare surfaces and on surfaces embedded with hydrophilic beads. It was found that a thin, stiff, hydrophilic, silica film formed on top of the PDMS material, following its hydrophilization by UV radiation. The hydrophobic recovery of bare PDMS material is the result of an overlap of various nano-mechanical, and diffusional processes, each with its own dynamics rate, which were analyzed in parallel. The hydrophobic recovery presents a hysteresis, with surface hydrophobicity recovering only partially due to a thin, but resilient top silica layer. The monitoring of hydrophobic recovery of PDMS embedded with hydrophilic beads revealed that this is delayed, and then totally stalled in the few-micrometer vicinity of the embedded hydrophilic beads. This region where the hydrophobic recovery stalls can be used as a good approximation of the depth of the resilient, moderately hydrophilic top layer on the PDMS material. The complex processes of hydrophilization and subsequent hydrophobic recovery impact the design, fabrication, and operation of PDMS materials and devices used for diagnostics and medical procedures. Consequently, especially considering the emergence of new surgical procedures using elastomers, the impact of hydrophobic recovery on the surface of PDMS warrants more comprehensive studies.

12 August 2025 in Vaccines
Verified
Journal Article
Open access
PDF file
MD Faizul Hussain KhanMD Faizul Hussain Khan
MD Faizul Hussain Khan
Floriane BaudinFloriane Baudin
Floriane Baudin
APAyyappasamy Sudalaiyadum Perumal
Ayyappasamy Sudalaiyadum Perumal
Amine KamenAmine Kamen
Amine Kamen
The instability of mRNA vaccines presents significant challenges for their storage, transportation, and large-scale distribution, particularly in resource-limited countries. Recently, freeze-drying (lyophilization) has been considered as a promising approach for preserving mRNA vaccine efficacy. This formulation technique enhances the long-term stability of mRNA vaccines by converting them into a stable dry powder. The purpose of this review is to provide an overview of the current knowledge on the progress of freeze-drying techniques for mRNA vaccines, with emphasis on the associated challenges. This review highlights the factors influencing the stability of freeze-dried mRNA vaccines and provides a comprehensive overview of the formulation components, including excipients, buffers, and surfactants, as well as the process parameters and storage conditions that aim to improve stability and shelf-life. By providing these insights, this review supports the advancement of more robust, scalable, and efficient lyophilization protocols, ultimately addressing the stability limitations of mRNA vaccines and enhancing their global accessibility.

30 January 2019 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
SKSara Kheireddine
Sara Kheireddine
APAyyappasamy Sudalaiyadum Perumal
Ayyappasamy Sudalaiyadum Perumal
ZSZachary Smith
Zachary Smith
Dan V. NicolauDan V. Nicolau
Dan V. Nicolau
Sebastian Wachsmann-HogiuSebastian Wachsmann-Hogiu
Sebastian Wachsmann-Hogiu
In this paper we present for the first time a system comprised of two mobile phones, one for illumination and the other for microscopy, as a portable, user-friendly, and cost-effective microscopy platform for a wide range of applications. Versatile and adaptive illumination is made with a Retina display of an Apple mobile phone device. The phone screen is used to project various illumination patterns onto the specimen being imaged, each corresponding to a different illumination mode, such as bright-field, dark-field, point illumination, Rheinberg illumination, and fluorescence microscopy. The second phone (a Nokia phone) is modified to record microscopic images about the sample. This imaging platform provides a high spatial resolution of at least 2 μm, a large field-of-view of 3.6 × 2.7 mm, and a working distance of 0.6 mm. We demonstrate the performance of this platform for the visualization of microorganisms within microfluidic devices to gather qualitative and quantitative information regarding microorganism morphology, dimension, count, and velocity/trajectories in the x–y plane.