Viola Tokárová

Viola Tokárová

Auto-generated profile, based on publicly available information

Viola Tokárová

Department of Chemical Engineering, University of Chemistry and Technology Prague, Technická 5, Prague, Czech Republic

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2021 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
VTViola Tokárová
Viola Tokárová
APAyyappasamy Sudalaiyadum Perumal
Ayyappasamy Sudalaiyadum Perumal
MNMonalisha Nayak
Monalisha Nayak
HSHenry Shum
Henry Shum
OKOndřej Kašpar
Ondřej Kašpar
Dan V. NicolauDan V. Nicolau
Dan V. Nicolau
Understanding the motility behavior of bacteria in confining microenvironments, in which they search for available physical space and move in response to stimuli, is important for environmental, food industry, and biomedical applications. We studied the motility of five bacterial species with various sizes and flagellar architectures (Vibrio natriegens, Magnetococcus marinus, Pseudomonas putida, Vibrio fischeri, and Escherichia coli) in microfluidic environments presenting various levels of confinement and geometrical complexity, in the absence of external flow and concentration gradients. When the confinement is moderate, such as in quasi-open spaces with only one limiting wall, and in wide channels, the motility behavior of bacteria with complex flagellar architectures approximately follows the hydrodynamics-based predictions developed for simple monotrichous bacteria. Specifically, V. natriegens and V. fischeri moved parallel to the wall and P. putida and E. coli presented a stable movement parallel to the wall but with incidental wall escape events, while M. marinus exhibited frequent flipping between wall accumulator and wall escaper regimes. Conversely, in tighter confining environments, the motility is governed by the steric interactions between bacteria and the surrounding walls. In mesoscale regions, where the impacts of hydrodynamics and steric interactions overlap, these mechanisms can either push bacteria in the same directions in linear channels, leading to smooth bacterial movement, or they could be oppositional (e.g., in mesoscale-sized meandered channels), leading to chaotic movement and subsequent bacterial trapping. The study provides a methodological template for the design of microfluidic devices for single-cell genomic screening, bacterial entrapment for diagnostics, or biocomputation. Significance Understanding bacterial movement is crucial for health, agriculture, environment, and industry. Studying the motility of five bacterial species in microfluidic environments showed that bacterial motility behavior is the result of a “tug-of-war” between hydrodynamics and local nanomechanics. In less confining spaces, bacterial motility is governed by hydrodynamics and can be approximately predicted by modeling developed for the simplest species. Conversely, in tightly confining environments, movement is mainly controlled by the steric interactions between flagella and the surrounding walls. Intriguingly, in mesoscale-sized geometries, hydrodynamics and bacterium–wall interactions overlap, either “constructively,” leading to smooth movement in straight channels, or “destructively,” leading to trapping. Our study provides a methodological template for the development of devices for single-cell genomics, diagnostics, or biocomputation.

1 July 2015 in Powder Technology
Verified
Journal Article
Closed access
SOSarang Oka
Sarang Oka
HEHeather Emady
Heather Emady
OKOndřej Kašpar
Ondřej Kašpar
VTViola Tokárová
Viola Tokárová
FMFernando Muzzio
Fernando Muzzio
RRRohit Ramachandran
Rohit Ramachandran

1 January 2015 in Advanced Powder Technology
Verified
Journal Article
Closed access
SOSarang Oka
Sarang Oka
OKOndřej Kašpar
Ondřej Kašpar
VTViola Tokárová
Viola Tokárová
KSKoushik Sowrirajan
Koushik Sowrirajan
HWHuiquan Wu
Huiquan Wu
RRRohit Ramachandran
Rohit Ramachandran

19 January 2016 in Biomedical Microdevices
Verified
Journal Article
Open access
PDF file
LFLuisa Filipponi
Luisa Filipponi
PLPeter Livingston
Peter Livingston
OKOndřej Kašpar
Ondřej Kašpar
VTViola Tokárová
Viola Tokárová
Dan V. NicolauDan V. Nicolau
Dan V. Nicolau
Micro-contact printing, μCP, is a well-established soft-lithography technique for printing biomolecules. μCP uses stamps made of Poly(dimethylsiloxane), PDMS, made by replicating a microstructured silicon master fabricated by semiconductor manufacturing processes. One of the problems of the μCP is the difficult control of the printing process, which, because of the high compressibility of PDMS, is very sensitive to minute changes in the applied pressure. This over-sensitive response leads to frequent and/or uncontrollable collapse of the stamps with high aspect ratios, thus decreasing the printing accuracy and reproducibility. Here we present a straightforward methodology of designing and fabricating PDMS structures with an architecture which uses the collapse of the stamp to reduce, rather than enlarge the variability of the printing. The PDMS stamp, organized as an array of pyramidal micro-posts, whose ceiling collapses when pressed on a flat surface, replicates the structure of the silicon master fabricated by anisotropic wet etching. Upon application of pressure, depending on the size of, and the pitch between, the PDMS pyramids, an air gap is formed surrounding either the entire array, or individual posts. The printing technology, which also exhibits a remarkably low background noise for fluorescence detection, may find applications when the clear demarcation of the shapes of protein patterns and the distance between them are critical, such as microarrays and studies of cell patterning.

17 April 2020 in RSC Advances
Verified
Journal Article
Open access
PDF file
OKO. Kašpar
O. Kašpar
AKA. H. Koyuncu
A. H. Koyuncu
AHA. Hubatová-Vacková
A. Hubatová-Vacková
MBM. Balouch
M. Balouch
VTV. Tokárová
V. Tokárová
Microfluidic devices, allowing superior control over the spatial and temporal distribution of chemical substances and high process reproducibility, are nowadays essential in various research areas and industrial fields where the traditional “macroscopic” approach was no longer able to keep up with the increasing demands of high-end applications. In the present work, internal mixing of droplets formed by a flow-focusing X-junction at constant flow rates of both phases for three different channel heights (i.e. 20, 40 and 60 μm) was investigated and characterised. Both experimental methods and 3D CFD simulations were employed in order to resolve governing factors having an impact on internal mixing and homogenization time of model tracers inside of droplet reactors. Additionally, the influence of channel height on internal mixing was experimentally studied for continuous preparation of iron oxide nanoparticles by co-precipitation reaction. Since the initial nucleation phase is strongly affected by mixing and spatial distribution of all reactants, the final particle size and particle size distribution (PSD) can be used as direct indicators of mixing performance. It has been demonstrated that the smallest 20 μm channels provided narrower PSD and smaller particle mean size compared to higher channels.

1 October 2019 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
OKO. Kašpar
O. Kašpar
AKA. H. Koyuncu
A. H. Koyuncu
APA. Pittermannová
A. Pittermannová
PUP. Ulbrich
P. Ulbrich
VTV. Tokárová
V. Tokárová