Despite advancements in surgical techniques, including the utilization of intra-operative fluoroscopy and custom surgical guides, intra-articular implant placement during the pinning of capital physeal fractures can occur and may result in catastrophic complications. Our objective in this study was to compare the epiphyseal purchase afforded by a linear and triangular pattern of Kirschner wires for stabilizing femoral capital physeal fractures. Archived pelvic limb computed tomography scans of 16 skeletally immature dogs were obtained, from which virtual femoral models were created. Separate linear and triangular arrangements of three virtual 1.6 mm Kirschner wires were centered on the thickest region of the proximal epiphysis. The length of each Kirschner wire implanted within the proximal femoral epiphysis was measured. Kirschner wire placement in triangular and linear patterns resulted in a mean epiphyseal purchase for each wire of 8.4 mm and 8.0 mm, respectively. The cumulative Kirschner wire purchase was greater with the triangular pattern (p = 0.004). The mean difference in the cumulative wire purchase was 1.3 mm. The use of a triangular Kirschner wire pattern resulted in greater implant purchase within the epiphysis compared to the linear pattern. The triangular Kirschner wire pattern may reduce the risk of intra-articular implant placement by more closely centering the wires within the thickest region of the epiphysis.
This case series describes the clinical results following stabilization of comminuted diaphyseal femoral fractures, two of which extended into the proximal metaphyseal region, using an articulated intramedullary (IM) pin-hybridized circular external fixator construct in three cats. An IM pin was placed to initially align and stabilize each fracture via an open reduction. The fixator construct consisted of a proximal partial ring arch and a distal stretch ring. Half-pins were used as fixation elements on the proximal ring, whereas olive wires were used as fixation elements on the distal ring. All three fractures were acceptably reduced and aligned. The constructs afforded functional use of the limb during the post-operative convalescent period with few complications. The constructs were maintained for 8, 15, and 16 weeks until there was sufficient radiographic fracture healing for fixator removal. In one cat, the IM pin was maintained following fixator removal and was articulated with a single retained half-pin engaging the greater trochanter and femoral neck. All three cats were reported to have acceptable pelvic limb function at 12, 25, and 93 months following surgery, with two of the cats reported to have occasional, intermittent nominal lameness.