Sylvia Spies

Ms. Sylvia Spies

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2024 in Communications Chemistry
Verified
Journal Article
Open access
PDF file
LTLara van Tetering
Lara van Tetering
SSSylvia Spies
Sylvia Spies
QWQuirine D. K. Wildeman
Quirine D. K. Wildeman
KHKas J. Houthuijs
Kas J. Houthuijs
RORianne E. van Outersterp
Rianne E. van Outersterp
JOJos Oomens
Jos Oomens
Modern untargeted mass spectrometry (MS) analyses quickly detect and resolve thousands of molecular compounds. Although features are readily annotated with a molecular formula in high-resolution small-molecule MS applications, the large majority of them remains unidentified in terms of their full molecular structure. Collision-induced dissociation tandem mass spectrometry (CID-MS2) provides a diagnostic molecular fingerprint to resolve the molecular structure through a library search. However, for de novo identifications, one must often rely on in silico generated MS2 spectra as reference. The ability of different in silico algorithms to correctly predict MS2 spectra and thus to retrieve correct molecular structures is a topic of lively debate, for instance in the CASMI contest. Underlying the predicted MS2 spectra are the in silico generated product ion structures, which are normally not used in de novo identification, but which can serve to critically assess the fragmentation algorithms. Here we evaluate in silico generated MSn product ion structures by comparison with structures established experimentally by infrared ion spectroscopy (IRIS). For a set of three dozen product ion structures from five precursor molecules, we find that virtually all fragment ion structure annotations in three major in silico MS2 libraries (HMDB, METLIN, mzCloud) are incorrect and caution the reader against their use for structure annotation of MS/MS ions.

18 May 2025 in Cancers
Verified
Journal Article
Open access
PDF file
SSSylvia Spies
Sylvia Spies
ENElina Nazarian
Elina Nazarian
SASrinivas Annavarapu
Srinivas Annavarapu
PCPaola Collini
Paola Collini
ACAurore Coulomb-L'Herminé
Aurore Coulomb-L'Herminé
MGMarie Louise Groot
Marie Louise Groot
Background/Objectives: Wilms tumors, the most common pediatric renal tumors, are heterogeneous and consist of varying amounts of three components: blastema, epithelium, and stroma. Postoperative chemotherapy is tailored based on risk group classification and stage. Due to this heterogeneity, pathologists perform extensive tumor sampling to ensure accurate classification. Higher-harmonic-generation microscopy (HHGM) is an innovative imaging technique that enables rapid visualization of fresh tissue without preparation or staining. This makes it particularly valuable for sample selection, as the tissue can be reused for further analysis. This study aims to evaluate the accuracy of pathologists in distinguishing normal renal tissue, abnormal renal tissue, and three types of pediatric renal tumors, Wilms tumor, renal cell carcinoma, and congenital mesoblastic nephroma, in HHGM images. Methods: Twenty-nine samples from eighteen patients with a pediatric renal tumor were imaged using an HHG microscope and subsequently processed for histological analysis. Overview images of the samples were acquired at a rate of 10 s per mm2, while high-quality images took 1 min per mm2. A multi-observer study involving ten international expert pathologists of the SIOP-RTSG was conducted. Results: Pathologists were able to differentiate between normal and abnormal tissue with 100% (29/29) accuracy and correctly identified tumor versus non-tumor tissue with 97% (28/29) accuracy. Conclusions: These results show that HHGM is a highly promising technique for the rapid assessment of pediatric renal tumor samples, particularly for evaluating sample representativeness.

12 May 2025 in Cancers
Verified
Journal Article
Open access
PDF file
SSSylvia Spies
Sylvia Spies
ENElina Nazarian
Elina Nazarian
FBFelix Bremmer
Felix Bremmer
IGIvan A. Gonzalez
Ivan A. Gonzalez
João LoboJoão Lobo
João Lobo
MGMarie Louise Groot
Marie Louise Groot
Background/Objectives: Pediatric gonadal tumors are rare tumors, and germ cell tumors (GCTs) are the most common subgroup. GCTs are heterogeneous tumors and have different subtypes that can be either benign or malignant. Therefore, extensive sampling of the resected tumor is required to obtain an accurate diagnosis. Higher harmonic generation microscopy (HHGM) is an innovative imaging technique that enables rapid visualization of fresh tissue without the need for preparation or staining. This makes it particularly valuable for sample selection, as the tissue can be reused for further analysis. This study aims to evaluate the accuracy of pathologists detecting normal gonadal tissue, germ cell tumors, and other pediatric gonadal tumors in HHGM images. Methods: Twenty-eight samples of twenty-two patients with a germ cell tumor or other gonadal tumor were imaged with the HHG microscope and subsequently processed for histology. Overview images of the samples were made in 10 s per mm2, and high-quality images in 1 min per mm2. A multi-observer study was performed with five expert pathologists. Results: Pathologists were able to differentiate between tumor and non-tumor tissue with an accuracy of 75% (21/28) on the HHGM images versus an accuracy of 89% (25/28) on the corresponding histology. Discrepancies mainly concerned teratoma cases for HHGM as well as H&E, indicating that sampling errors of these heterogeneous tumors affected the outcomes of this study adversely. Conclusions: Although the sample size was limited by the rarity of these tumors, our data show that HHGM is a promising technique for the rapid assessment of pediatric gonadal tumor samples, particularly in evaluating their representativeness.

14 September 2024 in European Respiratory Journal
Verified
Conference Paper
Closed access
SSSylvia Spies
Sylvia Spies
SVSofi Vassileva
Sofi Vassileva
MZMengyao Zhou
Mengyao Zhou
TRTeodora Radonic
Teodora Radonic
JAJouke T. Annema
Jouke T. Annema
MGMarie Louise Groot
Marie Louise Groot
Introduction: Asthma is characterized by airway remodeling, including an increase in airway smooth muscle (ASM), changes in the extracellular matrix (ECM) and epithelium, and assessment of these can contribute to the diagnosis of asthma. Higher harmonic generation microscopy (HHGM) is a fast, label-free imaging technique that combines third harmonic generation (THG), second harmonic generation (SHG), and two-photon excited autofluorescence (2PEF), to visualize cells, collagen and elastin, respectively, in 3D in unprocessed tissue. Hypothesis & Aim: We hypothesize that assessment of the epithelium and ECM in HHGM-images is a faster and less demanding method to provide information on airway remodeling. In this proof of principle study, we tested this hypothesis by investigating differences in epithelium and ECM between healthy volunteers and asthma patients. Methods & Results: Bronchoscopically obtained airway biopsies from asthma patients and healthy volunteers were immediately imaged by HHGM without further processing steps. In a few minutes 2D overview scans were made for each biopsy and Z-stacks from regions of interest, to characterize the airway wall layers in 3D. Changes in epithelium and ECM were found. Conclusion: Assessment of the HHGM visualized epithelium and ECM in the airway biopsies has potential to give new insights into airway remodeling in asthma. erj;64/suppl_68/PA5248/F1 F1 F1

5 September 2026
Verified
Conference Paper
Closed access
SSSylvia Spies
Sylvia Spies
NSNour Sukkari
Nour Sukkari
PGPatrick J. Gonzalez
Patrick J. Gonzalez
TRTeodora Radonic
Teodora Radonic
DHDavid J. Heineman
David J. Heineman
MGMarie Louise Groot
Marie Louise Groot
Introduction: Rapid on-site evaluation (ROSE) provides rapid feedback during bronchoscopies, but requires experienced personnel and is not available in every hospital. Higher harmonic generation (HHG) microscopy enables visualization of tissue without preparation or staining, and provides a clear distinction between collagen, elastin and other tissue components. Aims and objectives: We hypothesize that artificial intelligence (AI) based analysis of HHG images can rapidly provide feedback on sample representativity and diagnosis. Methods: Fresh forceps biopsies, cryobiopsies and resection samples were imaged on-site using an HHG microscope. Representative HHG images were manually annotated for 16 tissue components, including normal lung structures (e.g. bronchial epithelium, cartilage, glands, macrophages) and malignancies. We trained a nnU-Net to perform multi-class segmentation of these tissue components. Results: We annotated HHG images of 20 biopsies (14 patients) and 9 resection samples (9 patients) for training. The trained model was tested on 118 biopsies of 57 patients. The training evaluation metric reached a value of 0.8, demonstrating consistent performance, in particular for tumor classes (Figure 1). Conclusion: The model is now ready to be tested further against pathological diagnoses. HHG combined with AI-based analysis enables rapid feedback within 5 minutes. This could further create an opportunity for a ‘one-stop-shop’ that combines diagnosis and treatment in a single procedure. erj;68/suppl_70/OA4465/F1 F1 F1