Although software testing is key to a safe society, the process itself is often perceived by students as boring and stressful. Therefore, only few consider a career in testing. The adverse effect is sub-optimally tested code, with dangerous bugs left undetected. A better understanding of what testers "feel" when learning the skill in class can remedy this situation, by means of personalized, motivating bio-feedback. In order to test our hypothesis, we propose an innovative approach that uses physiological wearable sensors (cardiac activity, respiration, and skin conductance) to monitor in real-time the affective state of testers engaged in a bug-hunting game. This is a work in progress. We present the envisioned methodology and the results of two feasibility experiments. The first experiment created a training dataset, by recording bio-signals and self-reports from eleven participants involved in a mood-induction session followed by a bug-hunting task. The second experiment showed that it is possible to use deep-learning to recognize emotions from a large set of labelled multimodal (ECG, EDA and ICG) physiological data. The classification accuracy using a binary (positive-negative) emotions model was 85%, higher than the accuracy obtained using a four-emotions (anxious, down, enthusiastic and relaxed) model (57%). Future work includes optimizing the sensory system, improving the accuracy of automated emotions recognition, increasing the validity of ground-truth emotions labelling, and investigating ways to provide individualized and formative (instead of summative) bio-feedback. The proposed approach can contribute to a more sentiment-aware education, and a more objective evaluation of the effect of teaching interventions.
Background/Objectives: Wilms tumors, the most common pediatric renal tumors, are heterogeneous and consist of varying amounts of three components: blastema, epithelium, and stroma. Postoperative chemotherapy is tailored based on risk group classification and stage. Due to this heterogeneity, pathologists perform extensive tumor sampling to ensure accurate classification. Higher-harmonic-generation microscopy (HHGM) is an innovative imaging technique that enables rapid visualization of fresh tissue without preparation or staining. This makes it particularly valuable for sample selection, as the tissue can be reused for further analysis. This study aims to evaluate the accuracy of pathologists in distinguishing normal renal tissue, abnormal renal tissue, and three types of pediatric renal tumors, Wilms tumor, renal cell carcinoma, and congenital mesoblastic nephroma, in HHGM images. Methods: Twenty-nine samples from eighteen patients with a pediatric renal tumor were imaged using an HHG microscope and subsequently processed for histological analysis. Overview images of the samples were acquired at a rate of 10 s per mm2, while high-quality images took 1 min per mm2. A multi-observer study involving ten international expert pathologists of the SIOP-RTSG was conducted. Results: Pathologists were able to differentiate between normal and abnormal tissue with 100% (29/29) accuracy and correctly identified tumor versus non-tumor tissue with 97% (28/29) accuracy. Conclusions: These results show that HHGM is a highly promising technique for the rapid assessment of pediatric renal tumor samples, particularly for evaluating sample representativeness.
11 December 2025 in Intensive Care Medicine Experimental
Lung ultrasound has become an indispensable tool in the management of acute respiratory failure, offering real-time, radiation-free bedside imaging. Its portability, repeatability, and high sensitivity for detecting pulmonary abnormalities have made it particularly valuable in critical care settings, especially during the Coronavirus disease 2019 pandemic. This narrative review explores the evolving role of lung ultrasound, examining both its established clinical applications and recent advances in artificial intelligence and imaging analysis. These developments emphasize the growing importance of lung ultrasound not only as a diagnostic tool but also as a platform for innovation, with artificial intelligence-driven approaches to further enhance its clinical utility.
Background/Objectives: Pediatric gonadal tumors are rare tumors, and germ cell tumors (GCTs) are the most common subgroup. GCTs are heterogeneous tumors and have different subtypes that can be either benign or malignant. Therefore, extensive sampling of the resected tumor is required to obtain an accurate diagnosis. Higher harmonic generation microscopy (HHGM) is an innovative imaging technique that enables rapid visualization of fresh tissue without the need for preparation or staining. This makes it particularly valuable for sample selection, as the tissue can be reused for further analysis. This study aims to evaluate the accuracy of pathologists detecting normal gonadal tissue, germ cell tumors, and other pediatric gonadal tumors in HHGM images. Methods: Twenty-eight samples of twenty-two patients with a germ cell tumor or other gonadal tumor were imaged with the HHG microscope and subsequently processed for histology. Overview images of the samples were made in 10 s per mm2, and high-quality images in 1 min per mm2. A multi-observer study was performed with five expert pathologists. Results: Pathologists were able to differentiate between tumor and non-tumor tissue with an accuracy of 75% (21/28) on the HHGM images versus an accuracy of 89% (25/28) on the corresponding histology. Discrepancies mainly concerned teratoma cases for HHGM as well as H&E, indicating that sampling errors of these heterogeneous tumors affected the outcomes of this study adversely. Conclusions: Although the sample size was limited by the rarity of these tumors, our data show that HHGM is a promising technique for the rapid assessment of pediatric gonadal tumor samples, particularly in evaluating their representativeness.