Compton scattering imaging with intense, high-energy synchrotron X-rays allows us to visualize a light element substance in an operating electrochemical device. In this paper, we report the first experiment of Compton scattering imaging (CSI) on an operating polymer electrolyte fuel cell (PEFC). The novelty of the CSI technique is a non-destructive direct observation of cross-sectional images with a sensitivity to light elements and a capability of simultaneous measurements with fluorescent X-rays of heavy elements. Analyses of the observed images provide the cross-sectional distribution of generated liquid water and its current density dependency. The results show that the amount of generated water increases in the vicinity of the cathode catalyst layer at current densities ranging from 100 to 500 mA/cm2, while it remains constant or slightly decreases from 500 to 900 mA/cm2. In both the gas diffusion layer and the channel, liquid water is observed near the channel and rib interface above 500 mA/cm2, indicating the formation of a liquid water flow path. In addition, simultaneous measurements of fluorescent Pt-Ka X-rays reveal a significant correlation between the generated liquid water and Pt catalysts, using the Pearson correlation coefficient. The result shows that water is dispersed in the catalyst layer without any correlation with the amount of Pt catalysts at low current densities, but water tends to be distributed in the Pt-rich areas at high current densities. This study demonstrates that Compton scattering imaging is one of the unique techniques to characterize the behavior of generated liquid water in an operating PEFC.
19 January 2022 in The Journal of Chemical Physics
How is the orientation of molecular liquids ordered on cooling? What are the basic structures of molecular glasses, e.g., close to the crystalline structure or some special structure such as icosahedral cluster? These are long-standing questions in liquid and glass physics. We have constructed a novel cryostat to prepare simple molecular glasses by vapor deposition (VD) and perform in situ synchrotron radiation X-ray diffraction experiments. The glassy state of a simple molecule CS2, which cannot be vitrified by normal liquid quenching, was successfully prepared with this instrument and its diffraction data were collected in a wide Q-range, 0.16-25.7 Å-1 with a high-energy diffractometer at BL04B2, SPring-8. The diffraction data of liquid CS2 were also recorded in a wide temperature range 160-300 K. These diffraction data were analyzed with molecular dynamics (MD) simulations and reverse Monte Carlo (RMC) fittings to investigate orientational correlation. From the obtained 3D structure models, the orientational correlation between neighboring CS2 molecules was investigated quantitatively as a function of temperature. At room temperature, the parallel and T-shaped arrangements are preferred for the nearest neighbor correlation. On cooling, these arrangements are developed gradually, and its rate became prominent below the melting temperature (162 K). In the glassy state, the slipped-parallel arrangement is dominant as well as the T-shaped arrangement. Both arrangements appear in CS2 crystal, indicating that the structure of glassy CS2 is close to that of crystalline CS2.
This review is focused on FC-BENTEN, an advanced synchrotron X-ray experimental database developed at SPring-8 with support from Japan’s New Energy and Industrial Technology Development Organization (NEDO). Designed to advance polymer electrolyte fuel cells (PEFCs) research, FC-BENTEN addresses challenges in improving efficiency, durability, and cost-effectiveness through data-driven approaches informed by materials informatics (MI). Through standardization of protocols for sample preparation, data acquisition, analysis, and formatting, the database ensures high-quality, reproducible data essential for reliable scientific outcomes. FC-BENTEN streamlines metadata creation using automated processes and template-based tools, enhancing data management, accessibility, and interoperability. Security measures include two-factor authentication, safeguarding sensitive information and maintaining controlled user access. Planned integration with MI platforms will broaden data cross-referencing capabilities, facilitate PEFC applications expansion, and guide future research. This review discusses FC-BENTEN’s architectural framework, metadata standardization efforts, and role in advancing PEFC research through a high-throughput experimental workflow. It illustrates how data-driven methods and standardized practices contribute to innovation, underscoring databases’ potential to accelerate next-generation PEFC technologies development.
We measured the X-ray diffraction data of liquid toluene at several temperatures between 300 and 180 K and those of glasses prepared by liquid quenching and vapor deposition (VD) at 3 K. The VD glasses annealed at 90 and 112 K were also measured at 3 K. Throughout the measurements, we used a custom-made cryostat for VD experiments and a high-energy X-ray diffractometer at BL04B2, SPring-8. The structure factor S(Q) of each state was successfully fitted using potential fitting with molecular dynamics simulation and reverse Monte Carlo methods. Interestingly, in both the liquid and glassy states, the most preferred intermolecular structure is not a parallel one, which is the most stable dimer in vacuo, but a T-shaped one in which two hydrogen atoms of a benzene ring point toward the benzene ring of a neighboring molecule. The abundance of the T-shaped and side-by-side structures increases with decreasing temperature and annealing of the VD glass. As one possibility, we propose that the T-shaped structure can constitute the cooperatively rearranging region conceived in the Adam–Gibbs theory.