Markku Linnainmaa

Dr. Markku Linnainmaa


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2007 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
MLMarkku Linnainmaa
Markku Linnainmaa
JLJuha Laitinen
Juha Laitinen
ALAri Leskinen
Ari Leskinen
OSOlli Sippula
Olli Sippula
PKPentti Kalliokoski
Pentti Kalliokoski
The performance of four sampling devices for inhalable dust and three devices for respirable dust was tested with different kinds of dusts in the laboratory and in the field. The IOM sampler was chosen as the reference method for inhalable dust, and the IOM sampler provided with the porous plastic foam media was used as the reference method for respirable dust. The other tested instruments were the Button sampler, the optical Grimm aerosol monitor, and the Dekati two-stage cascade impactor with cutoff sizes of 10 and 4 μ m. The study confirmed the applicability of the IOM and Button samplers. The new foam product followed the respirable criteria well. However, the foam sampler was unstable for measuring inhalable dust, probably due to its moisture absorption. In addition, high dust loads should be avoided with the foam sampler due to increase in filtering efficiency. The concentrations of inhalable dust measured with the Button sampler, the Grimm monitor, and the impactor sampler were usually close to those measured with the reference sampler. On the other hand, impactor sampling yielded higher respirable dust concentrations than the reference method in the field, which may have been caused by particle bounce; high dust loads should be avoided while using the impactor. The results also showed that the Grimm monitor enables real-time dust concentration determinations that are accurate enough for routine monitoring of occupational exposure and for testing efficiency of control measures in workplaces.

10 November 2009 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
SHSusanna Haatainen
Susanna Haatainen
JLJuha Laitinen
Juha Laitinen
MLMarkku Linnainmaa
Markku Linnainmaa
TRTiina Reponen
Tiina Reponen
PKPentti Kalliokoski
Pentti Kalliokoski
Concurrent samples were collected with Andersen and IOM foam samplers to determine whether if the IOM foam sampler can be applied to collect culturable microorganisms. Two different kinds of aerosols were studied: peat dust in a power plant and mist from coolant fluid aerosolized during grinding of blades and rollers in a paper mill. In the power plant, the concentrations of fungi were 2–3 times higher in the IOM samples than in the Andersen samples. However, more fungal genera were identified in the latter case. The methods yielded similar concentrations of bacteria and actinobacteria in the power plant. On the other hand, the performance of the IOM foam sampler was very poor in the paper mill, where stress-sensitive gram-negative bacteria dominated; low concentration of bacteria was detected in only one IOM sample even though the concentration of bacteria often exceeded even the upper detection limit in the Andersen impactor samples. It could be concluded that the IOM foam sampler performs quite well for collecting inhalable fungi and actinobacteria. However, the Andersen sampler provides better information on fungal genera and concentrations of gram-negative bacteria. Personal sampling with the IOM foam sampler provided an important benefit in the power plant, where the concentration ratio of personal to stationary samples was much higher for bacteria than for inhalable or respirable dust.

Tapani TuomiTapani Tuomi
Tapani Tuomi
MLMarkku Linnainmaa
Markku Linnainmaa
SPSirpa Pennanen
Sirpa Pennanen
To reduce the incidence of occupational diseases related to exposure to respirable silica at work, the main industries in the EU associated with respirable silica agreed on measures to improve working conditions through the application of good practices. These practices were included in “The Agreement on Workers Health Protection through the Good Handling and Use of Crystalline Silica and Products Containing it” (NEPSI agreement), signed in April 2006. In Finland, we have previously seen a decline in exposure to respirable quartz in relevant industries upon the treaty coming into effect, during the years 2006–2013. The present paper examines trends in exposure to respirable crystalline silica in Finland from 2006 to the end of 2017. In addition, we looked at changes in the number of exposed workers and the prevalence of silicosis and lung cancer associated with the exposure during the same period. The aim was to find out whether the decline in exposure previously recorded had continued, and whether this, in addition to the previously reported descent in exposure, was reflected in the amount and prevalence of occupational diseases associated with inhaling respirable quartz. In the present study, during the period 2013 to 2017 no further improvements were observed. The exposure remained at an average level of 20–50% of the current OEL8h. This is not necessarily sufficient to eliminate silicosis, lung cancer or other health effects associated with exposure to respirable silica in affected workplaces. To bring about further improvements in exposure, we suggest the present OEL8h in Finland (0.05 mg/m3) and particularly in the many EU countries with an OEL8h of 0.1 mg/m3 be lowered to 0.020–0.025 mg/m3. Secondly, branches outside of the NEPSI treaty where the number of exposed workers is increasing in Finland and possibly in some other EU countries as well, namely building and refinery industries, would be advised to sign the treaty. In addition, as a result of signing, good practices should be developed for work tasks where exposure to respirable silica is of concern in these industries.

11 July 2007 in Annals of Occupational Hygiene
Verified
Journal Article
Closed access
MLMarkku Linnainmaa
Markku Linnainmaa
JKJuhani Kangas
Juhani Kangas
MMMilja Mäkinen
Milja Mäkinen
SMSirpa Metsärinne
Sirpa Metsärinne
ATAntti Tossavainen
Antti Tossavainen
PKPentti Kalliokoski
Pentti Kalliokoski
Refractory ceramic fibres (RCF) are used in thermal isolation in the metal industry where high temperatures are regularly employed. Asbestos materials were earlier commonly used for these purposes. In this work, two Finnish steel plants, three foundries and a repair shop were studied for the ceramic fibre exposure of their workers under normal production and during the replacement of oven insulation. Personal and stationary sampling was used together with a novel nasal lavage sampling for the evaluation of personal exposure. Fibres were counted with optical and electron microscopy and they were identified using an energy-dispersive X-ray analyser. Ceramic fibres were found in most production phases [range <0.01-0.29 fibres per cubic centimetre (f cm(-3))]. Considerably higher fibre counts were obtained during the maintenance work (range <0.01-14.2 f cm(-3)). Nasal sampling was found to correlate with the airborne fibre concentrations at the group level. The mean fibre concentrations varied from 34 to 6680 f ml(-1) of lavage liquid. Use of personal respiratory protectors diminished the exposure on the average as analysed in the lavage specimens, but the effect of respirator use did not appear clearly in the results. Because of the heat conditions, the workers used the respirators for a strict minimum period. A considerable exposure to RCF occurs in the studied plants. Its risk should be evaluated and managed more closely in view that the material is carcinogenic. Use of personal respiratory protectors should be encouraged. Their effective use could be verified by the nasal sampling for fibres after the work shift.

1 July 2003 in AIHA Journal
Verified
Journal Article
Closed access
MLMarkku Linnainmaa
Markku Linnainmaa
HKHannu Kiviranta
Hannu Kiviranta
JLJuha Laitinen
Juha Laitinen
SLSirpa Laitinen
Sirpa Laitinen
The study evaluated the effects of triazine use and machine enclosure on workers' exposure to bacteria, endotoxins, and formaldehyde in the use of metalworking fluids (MWF). Concentrations of triazine and bacterial contaminants were monitored in bulk samples of MWF from two machines in one workplace. One of the machines was used normally; triazine was added to the other when needed. Air sampling was used to estimate workers' exposure to endotoxins at 18 workplaces near enclosed and open machines. Concentrations of triazine in MWF and formaldehyde in the air were measured. Some recirculating local exhaust ventilation systems were also tested. The endotoxin and bacteria concentrations in the biocide test of MWF rapidly increased when the biocide levels decreased below 500 ppm. Airborne concentrations of endotoxins were substantially lower near enclosed machines than near open ones. Concentrations of airborne formaldehyde were below the Finnish occupational exposure limit at the existing levels of triazine in MWF. Concentrations of triazine in MWF correlated well with those of formaldehyde in the air near the machines (correlation coefficient r=.69). The results showed that the triazine levels in MWF should continuously be kept high enough (>500 ppm) to prevent workers' exposure to endotoxins and bacteria. Overdosing with triazine, however, should be avoided, so that the levels of airborne formaldehyde remain low. Triazine levels in MWF can be followed by the method described in this article. Workers' exposure to contaminants of MWF can be reduced substantially by enclosing the machines and equipping them with local exhausts.

1 May 2003 in AIHA Journal
Verified
Journal Article
Closed access
MTMarja Teikari
Marja Teikari
MLMarkku Linnainmaa
Markku Linnainmaa
JLJuha Laitinen
Juha Laitinen
PKPentti Kalliokoski
Pentti Kalliokoski
JVJames Vincent
James Vincent
TRTaisto Raunemaa
Taisto Raunemaa
The performances of eight sampling devices were tested with mineral dusts in the laboratory and in a talc production plant. The IOM sampler was chosen as the reference method for inhalable dust, and the IOM samplers provided with the porous plastic foam media were used as the reference methods for both the thoracic and respirable aerosols. The other size-selective instruments tested included the Respicon virtual impactor, the optical GRIMM aerosol monitor, and a two-stage cascade impactor with cut points of 10 and 4 µm. The 37-mm cassettes were also included both as open- and closed-face versions. The study confirmed the usability of the IOM samplers for mineral dust, not only in its original version for the inhalable fraction but also its modified versions for the thoracic and respirable fractions. A high correlation with the two-stage impactor results is an indication of good reproducibility. The results increased the evidence that the 37-mm cassette is a poor indicator of inhalable aerosol. The concentrations obtained with both cassette methods were not only systematically too low but also showed large collection efficiency variability. Therefore, the results cannot be corrected by using correction factors. The concentrations of inhalable aerosol measured with the Respicon were generally low, but its performances for the thoracic and respirable fractions were closer to those for the reference samplers. The results also indicate that the GRIMM monitor is well-suited for such mineral dust determinations when very good accuracy is not required, but the immediate availability of the result is more important.