Katarzyna Rećko

Prof. Katarzyna Rećko

University of Białystok, Białystok, Podlaskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
VTVitalii Turchenko
Vitalii Turchenko
VKV.G. Kostishyn
V.G. Kostishyn
STSergei Trukhanov
Sergei Trukhanov
FDFrancoise Damay
Francoise Damay
FPFlorence Porcher
Florence Porcher
SPSilviu Polosan
Silviu Polosan

1 May 1997 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
DSDariusz Satuła
Dariusz Satuła
LDL. Dobrzyński
L. Dobrzyński
JWJ. Waliszewski
J. Waliszewski
KSK. Szymański
K. Szymański
KRKatarzyna Rećko
Katarzyna Rećko
KBK. Blinowski
K. Blinowski

3 November 1997 in Journal of Physics: Condensed Matter
Verified
Journal Article
Closed access
PDF file
KRKatarzyna Rećko
Katarzyna Rećko
MBM Biernacka
M Biernacka
LDL Dobrzynski
L Dobrzynski
KPK Perzynska
K Perzynska
DSDariusz Satuła
Dariusz Satuła
FBF Bourée
F Bourée
The powder samples of (x = 4, 5 and 6) alloys have been measured by means of magnetization, Mössbauer effect, x-ray and neutron diffraction techniques in the temperature range 1.5 - 400 K. Both neutron and x-ray diffraction experiments showed that the positions f in all samples are occupied by iron, while the iron atoms in the samples with x = 5 and 6 locate also at j sites. A little f - j disorder exists in . The paper shows a change of the magnetic structure with an increase of iron content. The magnetic moments lie in a basal a - b plane. Iron atoms in alloy order antiferromagnetically. and alloys exhibit in general a ferromagnetic behaviour. However a detailed distribution of magnetic moments among different sites could not be determined unambiguously from the neutron data only. Nevertheless, combining information from neutron and Mössbauer experiments, one can infer that the ordering among iron atoms must be non-collinear. A magnetic ordering among uranium atoms has been found in only. Low-temperature thermal expansion varies nonlinearly with temperature and in all samples is negligible at low temperatures.

1 February 2000 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
KSK. Szymański
K. Szymański
MBM. Biernacka
M. Biernacka
LDL. Dobrzyński
L. Dobrzyński
KPK. Perzyńska
K. Perzyńska
KRKatarzyna Rećko
Katarzyna Rećko
PZP. Zaleski
P. Zaleski

31 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
MTMarzena Tokarewicz
Marzena Tokarewicz
MGMałgorzata Gra̧dzka-Dahlke
Małgorzata Gra̧dzka-Dahlke
KRKatarzyna Rećko
Katarzyna Rećko
Magdalena LepickaMagdalena Lepicka
Magdalena Lepicka
KCKamila Czajkowska
Kamila Czajkowska
High-entropy alloys are a new generation of materials that have attracted the interest of numerous scientists because of their unusual properties. It seems interesting to use these alloys in biomedical applications. However, for this purpose, the basic condition of corrosion resistance must be fulfilled. In this article, selected corrosion properties of self-composed high-entropy alloys are investigated and compared with conventional biomedical alloys, that is titanium alloys and stainless steels. Corrosive parameters were determined using the potentiodynamic method. X-ray diffraction studies were performed to characterize the crystal structures. Microstructures of the prepared materials were examined using a scanning electron microscope, and surface hardness was measured by the Vickers method. The results show that investigated high-entropy alloys are characterized by simple structures. Three out of four tested high-entropy alloys had better corrosion properties than conventional implant alloys used in medicine. The Al0.7CoCrFeNi alloy was characterized by a corrosion potential of −224 mV and a corrosion current density of 0.9 μA/cm2; CoCrFeNiCu by −210 mV and 1.1 μA/cm2; TiAlFeCoNi by −435 mV and 4.6 μA/cm2; and Mn0.5TiCuAlCr by −253 mV and 1.3 μA/cm2, respectively. Therefore, the proposed high-entropy alloys can be considered as potential materials for biomedical applications, but this requires more studies to confirm their biocompatibility.

28 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
MKMarcin Klekotka
Marcin Klekotka
JDJan Ryszard Dąbrowski
Jan Ryszard Dąbrowski
KRKatarzyna Rećko
Katarzyna Rećko
The paper presents the results of in vitro studies of fretting and fretting corrosion processes of Ti6Al4V implant alloy in the environment of natural saliva and self-made mucin-based artificial saliva solutions. The study was performed on a specially designed fretting pin-on-disc tester, which was combined with a set used for electrochemical research. The open circuit potential measurements and potentiodynamic method were used for corrosion tests. The worn surfaces were subjected to microscopic observations and an evaluation of wear. Results were interpreted using the dissipated energy and third-body approaches. The X-ray diffraction analysis showed that titanium oxides constitute over 80% of the friction products. Special attention was paid to the role of saliva and its substitutes, which in certain cases can lead to the intensification of fretting wear. On the basis of the received results, a new phenomenological model of fretting corrosion processes was proposed. This model involves the formation of an abrasive paste that is a combination of metal oxides and the organic components of saliva.