The demand for metallic materials of exceptional tribological performance is rapidly growing due to constant development of automotive, tool or implant industry. As great attention nowadays is being paid to the surfacemodified materials, there is a need of establishing reliable methods for evaluation of coated metallic alloys. In this paper, methods for thickness, adhesion and mechanical properties measurement of anti-wear coatings are considered. The importance of altering the mechanical properties of the coating with regards to its expected wear performance is also discussed. According to the numerous findings, it is reasonable to pay attention to the hardness and Young’s modulus of the developed coating, as well as on the mismatch between its Young’s modulus and the elastic modulus of the substrate material. Information provided in this paper has been thoroughly illustrated and enriched with our own experience in the field.
New composites containing a natural filler made of diatom shells (frustules), permitting the modification of polylactide matrix, were produced by Fused Deposition Modelling (3D printing) and were thoroughly examined. Two mesh fractions of the filler were used, one of <40 µm and the other of 40−63 µm, in order to check the effect of the filler particle size on the composite properties. The composites obtained contained diatom shells in the concentrations from 0% to 5% wt. (0−27.5% vol.) and were subjected to rheological analysis. The composites obtained as filaments of 1.75 mm in diameter were used for 3D printing. The printed samples were characterized as to hydrophilic–hydrophobic, thermal and mechanical properties. The functional parameters of the printed objects, e.g., mechanical characteristics, stability on contact with water and water contact angle, were measured. The results revealed differences in the processing behavior of the samples as well as the effect of secondary granulation of the filler on the parameters of the printing and mechanical properties of the composites.
This study discusses the effect of a duplex aging + nitriding process on the wear resistance of an aged double-phase titanium alloy, BT22. Nitriding was applied simultaneously with the heat treatment of the alloy, which is advantageous over the conventional heat and surface treatment methods applied to titanium alloys. According to the results, the thickness of the case depth of the nitrided samples was 40–50 μm. Moreover, nitrogen was uniformly dispersed in the substrate, which was indicated by the hardness tests. The average microhardness of the substrate material was 300 HV0.01, while the hardness of the top layer was 1190 HV0.01, which is an almost four-fold increase. The applied duplex treatment substantially affected the wear performance of the tested alloy. For the untreated alloy, the maximum coefficient of friction was 0.8, while in the surface-modified sample, the maximum fluctuations reached 0.6. The abrasive wear process was dominant in the nitrided samples, while delamination and adhesive wear were observed for the untreated specimens. The nitrided alloy exhibited double the wear resistance of the untreated samples. The proposed treatment does not require additional time or energy consumption, providing a substantial technological advantage over conventional methods. Though the alpha case reduces the mechanical performance of titanium, the nitriding of only the component sections intended to withstand friction will have a positive effect.
High-entropy alloys are a new generation of materials that have attracted the interest of numerous scientists because of their unusual properties. It seems interesting to use these alloys in biomedical applications. However, for this purpose, the basic condition of corrosion resistance must be fulfilled. In this article, selected corrosion properties of self-composed high-entropy alloys are investigated and compared with conventional biomedical alloys, that is titanium alloys and stainless steels. Corrosive parameters were determined using the potentiodynamic method. X-ray diffraction studies were performed to characterize the crystal structures. Microstructures of the prepared materials were examined using a scanning electron microscope, and surface hardness was measured by the Vickers method. The results show that investigated high-entropy alloys are characterized by simple structures. Three out of four tested high-entropy alloys had better corrosion properties than conventional implant alloys used in medicine. The Al0.7CoCrFeNi alloy was characterized by a corrosion potential of −224 mV and a corrosion current density of 0.9 μA/cm2; CoCrFeNiCu by −210 mV and 1.1 μA/cm2; TiAlFeCoNi by −435 mV and 4.6 μA/cm2; and Mn0.5TiCuAlCr by −253 mV and 1.3 μA/cm2, respectively. Therefore, the proposed high-entropy alloys can be considered as potential materials for biomedical applications, but this requires more studies to confirm their biocompatibility.