Background: Increased intra-abdominal pressure (IAP), autonomic reactions, and anesthetics all contribute to hemodynamic alterations during laparoscopic cholecystectomy. This study’s objectives are to measure noninvasively the intraoperative individual responses in cardiac and systemic hemodynamics, focusing on cardiac output (CO. L/min), stroke volume (SV, mL/min), systemic vascular resistance (SVR, dyn.s.cm−5), and noninvasive mean arterial blood pressure (MABP, mmHg) during and after peritoneal insufflation (cmH2O). The secondary objective was to evaluate the utility of EC as an adjunct to standard monitoring and to assess the individual differences. Methods: The CO and associated parameters were continuously and noninvasively monitored with the electrical cardiometry (EC, ICON, Osypka, Berlin Germany). Results: Seventy-three patients showed that when the IAP increased to 13 [IQR: 13-14] cmH2O, there was an overall percentage decrease in CO (−11.29%), MABP (−9.31%), and SVR (−23.16%) compared to pre induction with minimal changes in heart rate (HR). Individual variation and extreme reactions among certain patients were noted, with CO falling by −47.14% and MABP by −61.59, respectively, which can have major repercussions. Conclusions: The EC enabled real-time, non-invasive CO monitoring and detected significant cardio-hemodynamic changes that conventional monitors could miss. EC can supplement traditional monitors and give attending anesthesiologists access to more of patients’ vital information.
Background/Objectives: Thalassemias, a hereditary condition commonly linked to chronic anemia, require regular blood transfusions and repeated blood draws for assessments of hemoglobin (Hb) content, which can be uncomfortable. A promising substitute for laboratory hemoglobin testing is non-invasive spectrophotometric hemoglobin (SpHb) monitoring; however, its applicability particularly among blood transfusion-dependent thalassaemic patients needs to be investigated. This study’s primary goal was to investigate the relationships and agreements between SpHb, g/dL, and an automated hematology analyzer (Hb, g/dL) in this particular patient population. The secondary goal was to track how blood transfusions affect SpHb, g/dL, laboratory Hb, and pleth variability index (PVI, %). Methods: In this study, sixty patients were included. A Masimo Radical-7 pulse CO-oximeter was used to measure the SpHb, and a Sysmex XN-1000 hematological analyzer measured the laboratory Hb. Results: The results revealed a significant correlation between SpHb and laboratory Hb (n = 108, r = 0.587, p < 0.001) but also demonstrated that SpHb consistently overestimated laboratory Hb levels, with a mean bias of −1.18 g/dL (95% CI: −1.4344 to −0.9267). The Bland–Altman analysis showed a good degree of reliability between this bias (SpHb–Hb) and laboratory Hb (g/dL), with an Intra Class Correlation (ICC) of 0.613 but with a wide 95% CI ranging from 0.557 to 0.736 (t = 3.817, p < 0.001). The 95% limits of agreement ranged from −3.7893 to +1.4228 g/dL. Conclusions: This significant bias restricted the application of SpHb as a trustworthy method for assessing hemoglobin levels in patients with blood transfusion-dependent thalassemia. Nonetheless, the capability to monitor SpHb and PVI variations during blood transfusions offered a real-time assessment of the impact of transfusions on patients’ hemoglobin levels and volume status.