Imran Alherz

Dr. Imran Alherz


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MAMaryam Alwabari
Maryam Alwabari
FAFatimah Alhamad
Fatimah Alhamad
FAFatimah Ahmed Alsahaf
Fatimah Ahmed Alsahaf
FAFatima Ali Al Amer
Fatima Ali Al Amer
FAFatma Alniniya
Fatma Alniniya
KHALED Ahmed YASSENKHALED Ahmed YASSEN
KHALED Ahmed YASSEN
Preoperative assessment of hemoglobin concentration in blood is important to diagnose anemia. The primary aim of this prospective diagnostic test accuracy study was to monitor non-invasive spectrophotometric hemoglobin (SpHb, g/dL) concentrations among adults prior to elective surgery and to investigate the correlation and agreement of SpHb with laboratory hemoglobin (Hb, g/dl). A secondary aim was to identify the anemia cut-off values for SpHb based on the World Health Organization (WHO) definitions for anemia. This study included 151 consecutive patients (age ≥ 18 year) presenting for preoperative evaluation prior to scheduled elective general or orthopedic surgery. Results identified the mean ± SD of SpHb at 11.43 ± 2.01 g/dL, which underestimated the mean laboratory Hb (12.64 ± 2.29 g/dL, p < 0.001). A bias mean difference (SpHb–Hb) of −1.21 g/dL, with a SD of 1.76, was reported. This bias (SpHb–Hb) was inversely correlated with the mean Hb concentrations. A positive correlation existed between SpHb and Hb, with a good degree of reliability and a significant Intra Class Correlation (ICC). SpHb diagnosed anemia in 32.3% and 60.3% of males and females, respectively. The SpHb cut-off values to identify anemia were 11.3 and 10.2 g/dL for males and females, respectively, with a sensitivity of 83.3% for males and only 62.9% for females. The specificity for males and females were 81% and 91.3%, respectively. SpHb sensitivity allows for anemia diagnosis among males, but not females. However, the specificity allows SpHb to rule out anemia for both.

5 December 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KHALED Ahmed YASSENKHALED Ahmed YASSEN
KHALED Ahmed YASSEN
NENawal Eltaib
Nawal Eltaib
FAFatimah Ahmed Alsahaf
Fatimah Ahmed Alsahaf
FAFatima Ali Al Amer
Fatima Ali Al Amer
FAFatimah Alhamad
Fatimah Alhamad
MAMaryam Alwabari
Maryam Alwabari
Patients with sickle cell disease (SCD) require repeated blood sampling for hemoglobin (Hb) concentration measurements. The primary aim of this study was to compare non-invasive spectrophotometric hemoglobin (SpHb, g/dL) measurements to those taken via an automated hematology analyzer (Hb, g/dL) in patients with SCD visiting outpatient clinics and to investigate the correlations and agreements between both measurement techniques. Secondarily, we aimed to identify the SpHb cut-off concentration for the diagnosis of anemia and to monitor the effects of the pleth variability index (PVI, %) and perfusion index (PI) on SpHb measurements. The results gained from the examination of one hundred and fifty-eight patients indicated that the SpHb measurements overestimated the lab Hb concentrations, with a mean (SpHb-Hb) bias of 0.82 g/dL (SD 1.29). The SpHb measurements were positively correlated with the Hb measurements (Kendall’s tau correlation (τ), n = 158, τ = 0.68, p < 0.001), with an intra-class correlation (ICC) of 0.67 and a 95% CI from 0.57 to 0.74 (p = 0.000). The SpHb cut-off concentration to diagnose anemia was 11.4 and 11.7 g/dL for males and females, respectively. SpHb sensitivity was low for males and females at 64.4% and 57.1%; however, the specificity was higher at 90.9% and 75%, with positive predictive values (PPVs) of 95.6 and 85.7, respectively. No correlation existed between SpHb measurements and the PVI (%) in contrast with a moderate correlation with the PI (r = 0.049, p = 0.54, and r = 0.36, p < 0.001, respectively). The mean PI was low at 2.52 ± 1.7. In conclusion, the SpHb measurements were consistently higher than the lab Hb concentrations, with a positive correlation. The sensitivity and precision of the SpHb measurements were lower than expected. However, the SpHb specificity and its positive predictive values (PPVs) indicated that it is less likely for a patient with a positive SpHb test result for anemia to be non-anemic. These results will allow SpHb measurement to play a role in excluding the presence of anemia. In light of the low PI values determined, the SpHb measurements were challenging to take and, thus, require further technological improvements.

25 March 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KHALED Ahmed YASSENKHALED Ahmed YASSEN
KHALED Ahmed YASSEN
WAWalla Aljumaiy
Walla Aljumaiy
IAImran Alherz
Imran Alherz
LALina A AlMudayris
Lina A AlMudayris
SASara Abdulhameed Albunyan
Sara Abdulhameed Albunyan
SSSHERIF SALEH
SHERIF SALEH
Background: Increased intra-abdominal pressure (IAP), autonomic reactions, and anesthetics all contribute to hemodynamic alterations during laparoscopic cholecystectomy. This study’s objectives are to measure noninvasively the intraoperative individual responses in cardiac and systemic hemodynamics, focusing on cardiac output (CO. L/min), stroke volume (SV, mL/min), systemic vascular resistance (SVR, dyn.s.cm−5), and noninvasive mean arterial blood pressure (MABP, mmHg) during and after peritoneal insufflation (cmH2O). The secondary objective was to evaluate the utility of EC as an adjunct to standard monitoring and to assess the individual differences. Methods: The CO and associated parameters were continuously and noninvasively monitored with the electrical cardiometry (EC, ICON, Osypka, Berlin Germany). Results: Seventy-three patients showed that when the IAP increased to 13 [IQR: 13-14] cmH2O, there was an overall percentage decrease in CO (−11.29%), MABP (−9.31%), and SVR (−23.16%) compared to pre induction with minimal changes in heart rate (HR). Individual variation and extreme reactions among certain patients were noted, with CO falling by −47.14% and MABP by −61.59, respectively, which can have major repercussions. Conclusions: The EC enabled real-time, non-invasive CO monitoring and detected significant cardio-hemodynamic changes that conventional monitors could miss. EC can supplement traditional monitors and give attending anesthesiologists access to more of patients’ vital information.

8 February 2025 in Anaesthesia, Pain & Intensive Care
Verified
Journal Article
Open access
PDF file
KHALED Ahmed YASSENKHALED Ahmed YASSEN
KHALED Ahmed YASSEN
IAImran Alherz
Imran Alherz
MAMuneera Saad Alnami
Muneera Saad Alnami
AAAtheer Ahmed Ali Almana
Atheer Ahmed Ali Almana
AOAsmaa Mohamed Kassem Osama
Asmaa Mohamed Kassem Osama
IKImtiyaz Ahmad Khan
Imtiyaz Ahmad Khan
Background & objective: Little is known about Malignant Hyperthermia (MH); as serious hypermetabolic response to anesthetic-related agents regarding its existence inside Saudi Arabia (KSA). Few MH incidents have been reported in periodic medical journals. To our knowledge, this nineteen-questionnaire survey is the first to be performed in KSA regarding MH. The main objective was to report suspected MH patients and the secondary objectives were to assess the availability of dantrolene vials, the management and outcome of the suspected patients. Methodology: Google Forms were sent to the anesthesiologists working in Ministry of Health hospitals at three geographical districts in KSA (Eastern Province, Riyadh, and Western Province) through anesthesiologists’ social platforms. The electronic link was accessible from October 10, 2022, to April 02, 2024. Results: Most of the 174 anesthesiologists, who replied, were consultants (65.5%), and 70.7% had more than 10 years of experience. 32 (18.4%) anesthesiologists reported having dealt with suspected MH patients during their careers, of which 21 were inside KSA hospitals. Anesthesiologists reporting having six or more vials of dantrolene were 113/174 (64.9%), whereas 23 (13.2%) reported having 3 to 6 vials and 13 (7.5%) 1 to 3 vials. Only 25 (14.4%) reported no vials. Of the anesthesiologists, 66 (37.9%) were aware of the locations of dantrolene in their city. According to 51.7% of respondents, 120 mg of dantrolene may be prepared in 30 min. Conclusion: Our survey sheds light on susceptible MH cases in Saudi Arabia that remain unpublished or inadequately reported. Establishing a dedicated MH management and database center is a pressing need. The current low number of reported MH cases should not be used as a justification to delay such an initiative, particularly given the absence of accurate statistics. Moreover, the study demonstrates variability in hospital preparedness for MH emergencies, which needs to be addressed urgently. Hospitals with inadequate monitoring systems or insufficient dantrolene supplies need to meet the required standards for optimal patient safety. Keywords: Anesthesia; Dantrolene; Malignant Hyperthermia; Perioperative Complications Citation: Yassen KA, Al Herz PM, Alnami MS, ALmana AA, Osama AMK, Dur I Shahwar, AlSubaie RS, Saleh S, Khan I. Query malignant hyperthermia patients in Saudi Arabia; A questionnaire-based mini-survey. Anaesth. pain intensive care 2025;29(5):328-337. DOI: 10.35975/apic.v29i5.2637 Received: December 27, 2024; Revised: January 23, 2025; Accepted: May 17, 2025