Lingyun Wang

Lingyun Wang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2025 in Processes
Verified
Journal Article
Open access
PDF file
CGChangzeng Guo
Changzeng Guo
JKJian Kang
Jian Kang
DWDesheng Wang
Desheng Wang
YLYun Liang
Yun Liang
LWLingyun Wang
Lingyun Wang
MTMin Tang
Min Tang
Pleated filter media are widely used in particulate filtration, but the particle deposition and pressure drop during particle loading remain insufficiently explored. This study visualizes the particle deposition patterns in pleated filter media, along with the evolution of pressure drop and the effective filtration area (EFA) using simulations. The results indicate that, as the volume of deposited particles increases, the pressure drop of the pleated filter media initially grows linearly, but this rate of increase accelerates as particle deposition continues. The particle deposition characteristics are related to the pleat ratio. A smaller pleat ratio results in a smaller initial EFA, leading to a high initial resistance growth rate. Conversely, a larger pleat ratio leads to faster aggregation of particles, resulting in a faster rise in the resistance growth rate. The dust-holding capacity is optimal at a pleat ratio of 6.67. When the inlet flow rate or the particle size increases, it is more favorable to reduce the pleat ratio. The reliability of the results is verified using experiments, and the error is within 20%. The findings provide theoretical and practical insights for optimizing the design of pleated filter media for better performance in particulate filtration.

3 April 2025 in Processes
Verified
Journal Article
Open access
PDF file
QXQingqing Xie
Qingqing Xie
JKJian Kang
Jian Kang
YLYun Liang
Yun Liang
HWHao Wang
Hao Wang
GXGuilong Xu
Guilong Xu
MTMin Tang
Min Tang
Ultra-high-efficiency filter media ensure high air cleanliness but need periodic replacement due to pressure drop increase. Adding a pre-filter can extend the filtration system’s service lifetime, yet the pre-filter and main-filter matching lacks systematic study. This research explored how different filter media combinations affected a two-stage ultra-high-efficiency filtration system’s performance. This study focused on five pre-filter grades (F7–F9, H10, H11) and two different types of main-filter media, fiberglass and composite. It was found that the F8 pre-filter media had the best effect on extending the service lifetime of BX and BX + PTFE. The service lifetimes were extended from 44 min and 70 min to 231 min and 326 min, respectively, reaching 5.25 times and 4.65 times the original lifetime. Moreover, the optimal pre-filter grade was less affected by the initial resistance of the main filter. Meanwhile, the BX + PTFE filtration system always showed a longer service lifetime and dust holding capacity compared to the BX filtration system. This study provides guidance for the design and combination of two-stage filters in the context of high-cleanliness applications as well as the improvement of multi-stage filter performance in building ventilation.

25 April 2025 in Separations
Verified
Journal Article
Open access
PDF file
LRLe Rong
Le Rong
YLYun Liang
Yun Liang
ZLZhaoqian Li
Zhaoqian Li
DWDesheng Wang
Desheng Wang
HWHao Wang
Hao Wang
MTMin Tang
Min Tang
Antibacterial filter materials have been effectively utilized for controlling biological contaminants and purifying indoor air, with the market for such materials experiencing continuous expansion. Currently, textile antibacterial testing standards are widely adopted to evaluate the antimicrobial efficacy of filter materials, yet no dedicated assessment protocols specifically tailored for filtration media have been established. This study aims to investigate the applicability of textile antibacterial testing methods to high-efficiency glass fiber filter materials (filtration efficiency > 99.9%), as well as to explore the factors that affect the rate of bacterial elution from high-efficiency glass fiber filter materials. By referencing the textile antibacterial testing standard (absorption method), significant discrepancies in bacterial recovery counts were observed between the high-efficiency glass fiber materials and the various textile control samples, with the former exhibiting a markedly lower recovery rate (approximately 10%). Pore structure and wettability analyses revealed the underlying causes of these differences. To ensure the accuracy of the antibacterial evaluation results, the effects of oscillation elution parameters (time and intensity) and material incubation conditions (duration, sealing and humidity) on bacterial recovery rates in glass fiber filter materials were systematically investigated to optimize the elution methodology. The results indicate that specimen type, size, elution method, incubation duration (4 h or 24 h), sealing conditions, and environmental humidity (10% or 30%, 60% and 95% RH) collectively influence bacterial recovery efficiency. The highest recovery efficiency (55%) was achieved when the filter materials were incubated in a sealed environment with humidity maintained at ≥60% RH. These findings emphasize the critical need to establish clear and specialized antibacterial performance testing standards for filter materials. The study provides essential guidance for developing material-specific evaluation protocols to ensure a reliable and standardized assessment of antimicrobial efficacy in high-efficiency filtration systems.

5 May 2026 in Processes
Verified
Journal Article
Open access
PDF file
MLMingyu Li
Mingyu Li
DWDesheng Wang
Desheng Wang
LWLingyun Wang
Lingyun Wang
YWYuhan Wang
Yuhan Wang
JXJinhao Xie
Jinhao Xie
HWHao Wang
Hao Wang
Air pollution has drawn increasing attention. The channel-type structure, as an ideal energy-saving and resistance-reducing strategy for air filters, can effectively lower filtration resistance. However, current commercial channel-type filters generally exhibit only medium or low filtration efficiency, and the use of plant fibers as raw material limits their application in high-efficiency filters. In this study, high-efficiency glass fiber filter paper was combined with a channel-type structure, and the formulation and processing techniques suitable for the channel-type design were systematically investigated, leading to the fabrication of channel-type high-efficiency filters. The optimal formulation was determined to be a blend of glass wool fibers and 6 mm Tencel fibers in a 6:4 ratio, coated with a thermosetting resin, which yielded filter paper suitable for wave-pleating. The resulting filter paper demonstrated a filtration efficiency of 99.9624%, a pressure drop of 265.6 Pa, and a pleat aspect ratio of 0.209. Using this formulation, pilot-scale filter paper was produced and wave-pleated under processing conditions including a roller speed of 5 m/min, a roller gap of 0.4 mm, and a roller temperature of 160 °C, which was then used to fabricate channel-type high-efficiency filters. The finished channel-type filters achieved a filtration efficiency of 99.9940% with a pressure drop of 164.0 Pa. Compared to traditional pleated filters of the same volume and efficiency rating, the channel-type filter exhibited a 49.53% larger filtration area, a 33.13% lower face velocity, and a 31.67% reduction in pressure drop. This work offers a novel approach to reducing resistance and enhancing efficiency in air filtration systems.